메뉴 건너뛰기




Volumn 27, Issue 4, 2005, Pages 471-480

Flexural strengthening of concrete beams with CFRP laminates bonded into slits

Author keywords

Carbon fibre reinforced polymer; Flexural strengthening; Reinforced concrete beams

Indexed keywords

BENDING STRENGTH; CARBON FIBER REINFORCED PLASTICS; CRACK INITIATION; MATHEMATICAL MODELS; NUMERICAL METHODS; PLASTIC LAMINATES; STIFFNESS; STRUCTURAL LOADS; SURFACE MOUNT TECHNOLOGY;

EID: 14044277488     PISSN: 09589465     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cemconcomp.2004.07.004     Document Type: Article
Times cited : (235)

References (22)
  • 2
    • 0032140247 scopus 로고    scopus 로고
    • Structural behaviour of composite RC beams with externally bonded CFRP
    • G. Spadea, F. Bencardino, and R.N. Swamy Structural behaviour of composite RC beams with externally bonded CFRP J. Compos. Constr. 2 3 1998 132 137 August
    • (1998) J. Compos. Constr. , vol.2 , Issue.3 , pp. 132-137
    • Spadea, G.1    Bencardino, F.2    Swamy, R.N.3
  • 4
    • 0032005601 scopus 로고    scopus 로고
    • Durability characteristics of concrete columns wrapped with FRP tow sheets
    • H. Toutanji, and P. Balaguru Durability characteristics of concrete columns wrapped with FRP tow sheets J. Mat. Civil Eng. ASCE 10 1 1998 52 57
    • (1998) J. Mat. Civil Eng. ASCE , vol.10 , Issue.1 , pp. 52-57
    • Toutanji, H.1    Balaguru, P.2
  • 7
    • 0036524130 scopus 로고    scopus 로고
    • Bond between near surface mounted FRP rods and concrete in structural strengthening
    • L. De Lorenzis, and A. Nanni Bond between near surface mounted FRP rods and concrete in structural strengthening ACI Struct. J. 99 2 2002 123 133 March-April
    • (2002) ACI Struct. J. , vol.99 , Issue.2 , pp. 123-133
    • De Lorenzis, L.1    Nanni, A.2
  • 8
    • 13944259375 scopus 로고    scopus 로고
    • Waterfront repair and upgrade-advanced technology demonstration
    • Site No. 2: Pier 12. NAVSTA San Diego Naval Facilities Engineering Service Center, Port Hueneme, CA
    • Warren GE. Waterfront repair and upgrade-advanced technology demonstration. Site No. 2: Pier 12. NAVSTA San Diego, Site specific report SSR-2419-SHR, Naval Facilities Engineering Service Center, Port Hueneme, CA, 1998
    • (1998) Site Specific Report , vol.SSR-2419-SHR
    • Warren, G.E.1
  • 9
    • 0002266268 scopus 로고    scopus 로고
    • Upgrading the transportation infrastructure: Solid RD decks strengthened with FRP
    • T. Alkhrdaji, A. Nanni, G. Chen, and M. Barker Upgrading the transportation infrastructure: solid RD decks strengthened with FRP Concrete Int. ACI 21 10 1999 37 41
    • (1999) Concrete Int. ACI , vol.21 , Issue.10 , pp. 37-41
    • Alkhrdaji, T.1    Nanni, A.2    Chen, G.3    Barker, M.4
  • 10
    • 0001523509 scopus 로고    scopus 로고
    • Myriad convention center floor system reinforcement
    • Dolan CW, Rizkalla S, Nanni A, editors ACI
    • Hogue T, Cornforth RC, Nanni A. Myriad convention center floor system reinforcement. Dolan CW, Rizkalla S, Nanni A, editors. In: Proceedings of the FRPRCS-4, ACI, 1999, 1145-61
    • (1999) Proceedings of the FRPRCS-4 , pp. 1145-1161
    • Hogue, T.1    Cornforth, R.C.2    Nanni, A.3
  • 11
    • 0012567106 scopus 로고    scopus 로고
    • Field evaluation of Masonry walls strengthened with FRP composites at the Malcolm Bliss Hospital
    • University of Missouri-Rolla, Rolla, MO
    • Tumialan G, Tinazzi D, Myers J, Nanni A. Field evaluation of Masonry walls strengthened with FRP composites at the Malcolm Bliss Hospital. Report CIES 99-8, University of Missouri-Rolla, Rolla, MO, 1999
    • (1999) Report CIES , vol.99 , Issue.8
    • Tumialan, G.1    Tinazzi, D.2    Myers, J.3    Nanni, A.4
  • 15
    • 3042779510 scopus 로고    scopus 로고
    • Modeling of bond between near-surface mounted CFRP laminate strips and concrete
    • J.M. Sena-Cruz, and J.A.O. Barros Modeling of bond between near-surface mounted CFRP laminate strips and concrete Computers Struct. J. 82 17-19 2004 1513 1521
    • (2004) Computers Struct. J. , vol.82 , Issue.17-19 , pp. 1513-1521
    • Sena-Cruz, J.M.1    Barros, J.A.O.2
  • 16
    • 0032707450 scopus 로고    scopus 로고
    • Flexural behavior of steel fiber reinforced concrete: Testing and modelling
    • J.A.O. Barros, and J.A. Figueiras Flexural behavior of steel fiber reinforced concrete: testing and modelling J. Mat. Civil Eng. ASCE 11 4 1999 331 339
    • (1999) J. Mat. Civil Eng. ASCE , vol.11 , Issue.4 , pp. 331-339
    • Barros, J.A.O.1    Figueiras, J.A.2
  • 19
    • 13944255074 scopus 로고    scopus 로고
    • Assessing the embedded length of epoxy-bonded carbon laminates by pull-out bending tests
    • J.M. Sena-Cruz, J.A.O. Barros, and R.M.C.M. Faria Assessing the embedded length of epoxy-bonded carbon laminates by pull-out bending tests Int. Conf. Compos. Constr. 2001 217 222
    • (2001) Int. Conf. Compos. Constr. , pp. 217-222
    • Sena-Cruz, J.M.1    Barros, J.A.O.2    Faria, R.M.C.M.3
  • 20
  • 22
    • 14044267426 scopus 로고
    • CEB-FIP Model Code. Comite Euro-International du Beton, Bulletin d'Information n 213/214, 1993
    • (1993) Bulletin d'Information , vol.213-214


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.