메뉴 건너뛰기




Volumn 2, Issue , 2004, Pages 1674-1679

On the analysis of knee biomechanics using a wearable biomechatronic device

Author keywords

Aging; Biomechanics; Biomechatronics; Knee movements

Indexed keywords

BIOMEDICAL EQUIPMENT; DEGREES OF FREEDOM (MECHANICS); GONIOMETERS; JOINTS (ANATOMY); KINEMATICS; MEDICAL PROBLEMS; MOTION ESTIMATION; NEUROLOGY;

EID: 14044255918     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (5)

References (13)
  • 1
    • 0017194221 scopus 로고
    • On-line elcctrogoniometric gait analysis
    • October
    • Bajd T, Stanic U, Kljajic M, Trnkoczy A. On-line elcctrogoniometric gait analysis. Comp Biomed Res 1976;9(5):439-44 October.
    • (1976) Comp Biomed Res , vol.9 , Issue.5 , pp. 439-444
    • Bajd, T.1    Stanic, U.2    Kljajic, M.3    Trnkoczy, A.4
  • 3
    • 0017334228 scopus 로고
    • Total motion knee goniometry
    • Townsend MA, Izak M, Jackson RN. Total motion knee goniometry. J Biomech 1977;10:183-93.
    • (1977) J Biomech , vol.10 , pp. 183-193
    • Ma, T.1    Izak, M.2    Jackson, R.N.3
  • 4
    • 0019159246 scopus 로고
    • Justification of triaxial goniometer for the measurement of joint rotation
    • Chao YS. Justification of triaxial goniometer for the measurement of joint rotation. J Biomech 1980;13:989-1006.
    • (1980) J Biomech , vol.13 , pp. 989-1006
    • Chao, Y.S.1
  • 5
    • 0029933407 scopus 로고    scopus 로고
    • Goniometer measurement and computer analysis of wrist angles and movements applied to occupational repetitive work
    • Hansson, G.A., Balogh, I., Ohlsson, K., Rylander, L., Skerfving, S., 1996. Goniometer measurement and computer analysis of wrist angles and movements applied to occupational repetitive work. J. Electromyogr. Kinesiol. 6 (1), 23-35.
    • (1996) J. Electromyogr. Kinesiol. , vol.6 , Issue.1 , pp. 23-35
    • Hansson, G.A.1    Balogh, I.2    Ohlsson, K.3    Rylander, L.4    Skerfving, S.5
  • 6
    • 14044273975 scopus 로고
    • Effects of extended space flight on body form of Skylab astronauts using biostereometric methods
    • Herron RE, editor
    • Whittle MW, Herron RE, Cuzzi JR, Hugg JE. Effects of extended space flight on body form of Skylab astronauts using biostereometric methods, pp. 588-589, in: Herron RE, editor. Biostereometrics 1974;74(708):30.
    • (1974) Biostereometrics , vol.74 , Issue.708 , pp. 588-589
    • Whittle, M.W.1    Herron, R.E.2    Cuzzi, J.R.3    Hugg, J.E.4
  • 8
    • 0022270338 scopus 로고
    • ELITE: A digital dedicated hardware system for movement analysis via real-time TV signal processing
    • Ferrigno G, and Pedotti A. ELITE: a digital dedicated hardware system for movement analysis via real-time TV signal processing. IEEE Trans Biomed Eng 1985;32(11):943-50.
    • (1985) IEEE Trans Biomed Eng , vol.32 , Issue.11 , pp. 943-950
    • Ferrigno, G.1    Pedotti, A.2
  • 9
    • 0041668171 scopus 로고    scopus 로고
    • Reliability and accuracy of different sensors of a flexible electrogoniometer
    • Shiratsu A, and Coury HJCG, "Reliability and accuracy of different sensors of a flexible electrogoniometer," Clinical Biomechanics, vol. 18(7), pp. 682-684, 2003.
    • (2003) Clinical Biomechanics , vol.18 , Issue.7 , pp. 682-684
    • Shiratsu, A.1    Coury, H.J.C.G.2
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, and DG Altman, "Statistical methods for assessing agreement between two methods of clinical measurement," Lancet, pp. 307-310, 1986.
    • (1986) Lancet , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 11
    • 14044274612 scopus 로고    scopus 로고
    • Dual-task interference during skill acquisition: Structural interference versus resource competition
    • Eversheim U, and Bock O, "Dual-task interference during skill acquisition: Structural interference versus resource competition.," Soc. Neurosi. Abstr. 27, 2001.
    • (2001) Soc. Neurosi. Abstr. , vol.27
    • Eversheim, U.1    Bock, O.2
  • 12
    • 14044265388 scopus 로고    scopus 로고
    • Sarcos, http://www.sarcos.com.
  • 13
    • 0141509892 scopus 로고    scopus 로고
    • Mobile ankle and knee perturbator
    • Andersen JB and Sinkjær T., Mobile Ankle and Knee Perturbator, IEEE Trans Biomed Eng, vol. 50, no. 10, pp. 1208-1211, 2003.
    • (2003) IEEE Trans Biomed Eng , vol.50 , Issue.10 , pp. 1208-1211
    • Andersen, J.B.1    Sinkjær, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.