메뉴 건너뛰기




Volumn 29, Issue 3, 2005, Pages 324-327

'Extension technique': A modified technique for brachio-cephalic fistula to prevent dialysis access-associated steal syndrome

Author keywords

Autogenous proximal arm fistula; Diabetes; Dialysis access associated steal syndrome; Extension technique; Prevention of steal

Indexed keywords

ADULT; AGED; ARM BLOOD FLOW; ARTERIOVENOUS FISTULA; ARTERY STEAL SYNDROME; ARTERY SURGERY; ARTICLE; BRACHIAL ARTERY; BRACHIOCEPHALIC VEIN; CLINICAL ARTICLE; CONTROLLED STUDY; DIABETES MELLITUS; DISEASE ASSOCIATION; FEMALE; HEMODIALYSIS; HIGH RISK PATIENT; HUMAN; MALE; MEDICAL ASSESSMENT; PRIORITY JOURNAL; RADIAL ARTERY; SAFETY; SURGICAL TECHNIQUE; SYMPTOM; ULNAR ARTERY; VASCULAR ACCESS; VASCULAR PATENCY; VEIN THROMBOSIS;

EID: 13944265307     PISSN: 10785884     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejvs.2004.09.018     Document Type: Article
Times cited : (35)

References (17)
  • 1
    • 0033850659 scopus 로고    scopus 로고
    • Understanding strategies for the treatment of ischemic steal syndrome after hemodialysis access
    • C.L. Wixon J.D. Hughes J.L. Mills Understanding strategies for the treatment of ischemic steal syndrome after hemodialysis access J Am Coll Surg 191 3 2000 301-310
    • (2000) J. Am. Coll. Surg. , vol.191 , Issue.3 , pp. 301-310
    • Wixon, C.L.1    Hughes, J.D.2    Mills, J.L.3
  • 2
    • 0031845731 scopus 로고    scopus 로고
    • Incidence and characteristics of patients with hand ischemia after a hemodialysis access procedure
    • A.H. Morsy M. Kulbaski C. Chen H. Isiklar A.B. Lumsden Incidence and characteristics of patients with hand ischemia after a hemodialysis access procedure J Surg Res 74 1 1998 8-10
    • (1998) J. Surg. Res. , vol.74 , Issue.1 , pp. 8-10
    • Morsy, A.H.1    Kulbaski, M.2    Chen, C.3    Isiklar, H.4    Lumsden, A.B.5
  • 4
    • 0033862505 scopus 로고    scopus 로고
    • Distal arterial flow in patients undergoing upper extremity dialysis shunting: A prospective study using doppler sonography
    • M. Goldfeld B. Koifman N. Loberant I. Krowll M. Haj Distal arterial flow in patients undergoing upper extremity dialysis shunting: A prospective study using doppler sonography Am J Roentgenol 175 2 2000 513-516
    • (2000) Am. J. Roentgenol. , vol.175 , Issue.2 , pp. 513-516
    • Goldfeld, M.1    Koifman, B.2    Loberant, N.3    Krowll, I.4    Haj, M.5
  • 5
    • 0035235706 scopus 로고    scopus 로고
    • Increasing the proportion of diabetics with AV fistulas
    • K. Konner Increasing the proportion of diabetics with AV fistulas Semin Dial 14 1 2001 1-4
    • (2001) Semin. Dial. , vol.14 , Issue.1 , pp. 1-4
    • Konner, K.1
  • 6
    • 0028304278 scopus 로고
    • Limitations of the use of arteriovenous fistulae in the cubital fossa
    • J. Elfstrom A. Lindell Limitations of the use of arteriovenous fistulae in the cubital fossa Scand J Urol Nephrol 28 1994 123-126
    • (1994) Scand. J. Urol. Nephrol. , vol.28 , pp. 123-126
    • Elfstrom, J.1    Lindell, A.2
  • 7
    • 0034045358 scopus 로고    scopus 로고
    • Long-term results of arteriovenous fistulas using transposed autologous basilic vein
    • G.J. Murphy S.A. White A.J. Knight T. Doughman M.L. Nicholson Long-term results of arteriovenous fistulas using transposed autologous basilic vein Br J Surg 87 6 2000 819-823
    • (2000) Br. J. Surg. , vol.87 , Issue.6 , pp. 819-823
    • Murphy, G.J.1    White, S.A.2    Knight, A.J.3    Doughman, T.4    Nicholson, M.L.5
  • 8
    • 0142087917 scopus 로고    scopus 로고
    • Primary vascular access surgery in a well defined geographical region: Long-term results of autogenous arteriovenous fistulas
    • V. Suominen M. Heikkinen J. Saarinen R. Zeitlin O. Wirta J. Salenius Primary vascular access surgery in a well defined geographical region: long-term results of autogenous arteriovenous fistulas Scand J Surg 92 3 2003 210-214
    • (2003) Scand. J. Surg. , vol.92 , Issue.3 , pp. 210-214
    • Suominen, V.1    Heikkinen, M.2    Saarinen, J.3    Zeitlin, R.4    Wirta, O.5    Salenius, J.6
  • 9
  • 10
    • 0034063316 scopus 로고    scopus 로고
    • Distal revascularization-interval ligation for maintenance of dialysis access and restoration of distal perfusion in ischemic steal syndrome
    • C.L. Wixon J.L. Mills Sr S.S. Berman Distal revascularization-interval ligation for maintenance of dialysis access and restoration of distal perfusion in ischemic steal syndrome Semin Vasc Surg 13 1 2000 77-82
    • (2000) Semin. Vasc. Surg. , vol.13 , Issue.1 , pp. 77-82
    • Wixon, C.L.1    Mills Sr., J.L.2    Berman, S.S.3
  • 11
    • 0042736166 scopus 로고    scopus 로고
    • Successful reversal of steal syndrome following creation of arteriovenous fistula by banding with a ringed Gore-Tex cuff: A new technique
    • V.E. Papalois K.N. Haritopoulos K. Farrington N.S. Hakim Successful reversal of steal syndrome following creation of arteriovenous fistula by banding with a ringed Gore-Tex cuff: A new technique Int Surg 88 1 2003 52-54
    • (2003) Int. Surg. , vol.88 , Issue.1 , pp. 52-54
    • Papalois, V.E.1    Haritopoulos, K.N.2    Farrington, K.3    Hakim, N.S.4
  • 13
    • 0036676062 scopus 로고    scopus 로고
    • Distal revascularization-interval ligation: A durable and effective treatment for ischemic steal syndrome after hemodialysis access
    • [discussion]
    • R.C. Knox S.S. Berman J.D. Hughes A.T. Gentile J.L. Mills Distal revascularization-interval ligation: A durable and effective treatment for ischemic steal syndrome after hemodialysis access J Vasc Surg 36 2 2002 250-255 [discussion]
    • (2002) J. Vasc. Surg. , vol.36 , Issue.2 , pp. 250-255
    • Knox, R.C.1    Berman, S.S.2    Hughes, J.D.3    Gentile, A.T.4    Mills, J.L.5
  • 14
    • 0028964486 scopus 로고
    • Comparison of ulnar and radial arterial blood-flow at the wrist
    • A.M. Tonks J. Lawrence M.J. Lovie Comparison of ulnar and radial arterial blood-flow at the wrist J Hand Surg [Br] 20 2 1995 240-242
    • (1995) J. Hand Surg. [Br] , vol.20 , Issue.2 , pp. 240-242
    • Tonks, A.M.1    Lawrence, J.2    Lovie, M.J.3
  • 15
    • 0037973625 scopus 로고    scopus 로고
    • Proximal radial artery as inflow site for native arteriovenous fistula
    • S.D. Bruns W.C. Jennings Proximal radial artery as inflow site for native arteriovenous fistula J Am Coll Surg 197 1 2003 58-63
    • (2003) J. Am. Coll. Surg. , vol.197 , Issue.1 , pp. 58-63
    • Bruns, S.D.1    Jennings, W.C.2
  • 16
    • 0642313054 scopus 로고    scopus 로고
    • Autogenous arteriovenous fistulas for haemodialysis: A review
    • J.A. Akoh S. Dutta Autogenous arteriovenous fistulas for haemodialysis: a review Niger Postgrad Med J 10 2 2003 125-130
    • (2003) Niger Postgrad. Med. J. , vol.10 , Issue.2 , pp. 125-130
    • Akoh, J.A.1    Dutta, S.2
  • 17
    • 0041913917 scopus 로고    scopus 로고
    • Identifying vascular access complications among ESRD patients in Europe. A prospective, multicenter study
    • [also see p. 66-8 and 99]
    • M.M. Elseviers J.P. Van Waeleghem Identifying vascular access complications among ESRD patients in Europe. A prospective, multicenter study Nephrol News Issues 17 8 2003 61-64 [also see p. 66-8 and 99]
    • (2003) Nephrol. News Issues , vol.17 , Issue.8 , pp. 61-64
    • Elseviers, M.M.1    Van Waeleghem, J.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.