메뉴 건너뛰기




Volumn 8, Issue 1, 2004, Pages 70-78

Acoustic Emission Characterization of Damage in Hybrid Fiber-Reinforced Polymer Rods

Author keywords

Acoustic detection; Damage; Fiber reinforced polymers; Glass fibers; Rods; Sensors

Indexed keywords

ACOUSTIC DETECTION; DAMAGE; FIBER-REINFORCED POLYMERS; RODS;

EID: 13944263548     PISSN: 10900268     EISSN: None     Source Type: Journal    
DOI: 10.1061/(ASCE)1090-0268(2004)8:1(70)     Document Type: Article
Times cited : (40)

References (21)
  • 1
    • 0031186689 scopus 로고    scopus 로고
    • Serviceability of concrete beams prestressed by carbon-fiber-reinforced- plastic bars
    • Abdelrahman, A. A., and Rizkalla, S. H. (1997). ":Serviceability of concrete beams prestressed by carbon-fiber-reinforced-plastic bars.": ACI Struct. J., 94(4), 447-457.
    • (1997) ACI Struct. J. , vol.94 , Issue.4 , pp. 447-457
    • Abdelrahman, A.A.1    Rizkalla, S.H.2
  • 4
    • 0035337270 scopus 로고    scopus 로고
    • Self-monitoring, pseudo-ductile, hybrid FRP reinforcement rods for concrete applications
    • Bakis, C. E., Nanni, A., Terosky, J. A., and Koehler, S. W. (2001). ":Self-monitoring, pseudo-ductile, hybrid FRP reinforcement rods for concrete applications.": Compos. Sci. Technol., 61, 815-823.
    • (2001) Compos. Sci. Technol. , vol.61 , pp. 815-823
    • Bakis, C.E.1    Nanni, A.2    Terosky, J.A.3    Koehler, S.W.4
  • 7
    • 0345510603 scopus 로고    scopus 로고
    • Fiber optic acoustic emission distributed crack sensor for large structures
    • Chen, Z., and Ansari, F. (2000). ":Fiber optic acoustic emission distributed crack sensor for large structures.": J. Struct. Control, 7(1), 119-129.
    • (2000) J. Struct. Control , vol.7 , Issue.1 , pp. 119-129
    • Chen, Z.1    Ansari, F.2
  • 8
    • 0025489199 scopus 로고
    • Developments in non-metallic prestressing tendons
    • Dolan, C. W. (1990). ":Developments in non-metallic prestressing tendons.": PCI J., 35(5), 80-88.
    • (1990) PCI J. , vol.35 , Issue.5 , pp. 80-88
    • Dolan, C.W.1
  • 10
    • 0032095598 scopus 로고    scopus 로고
    • Ductility of prestressed bridges using CFRP strands
    • Grace, N. F., and Sayed, G. A. (1998). ":Ductility of prestressed bridges using CFRP strands.": Concr. Int., 20(6), 25-30.
    • (1998) Concr. Int. , vol.20 , Issue.6 , pp. 25-30
    • Grace, N.F.1    Sayed, G.A.2
  • 11
    • 13944271885 scopus 로고    scopus 로고
    • Bond strength and strain distribution in the anchorage zone of post-tensioned CFRP tendons
    • F. Ansari, ed., ASCE, Reston, Va.
    • Gu, X., and Ansari, F. (2000). ":Bond strength and strain distribution in the anchorage zone of post-tensioned CFRP tendons.": Condition monitoring of materials and structures, F. Ansari, ed., ASCE, Reston, Va., 120-133.
    • (2000) Condition Monitoring of Materials and Structures , pp. 120-133
    • Gu, X.1    Ansari, F.2
  • 12
    • 84970461282 scopus 로고
    • Fiber optic interferometric sensor for the detection of acoustic emission within composite materials
    • Liu, K., Ferguson, S. M., and Measures, R. M. (1990). ":Fiber optic interferometric sensor for the detection of acoustic emission within composite materials.": Opt. Lett., 15(22), 1255-1257.
    • (1990) Opt. Lett. , vol.15 , Issue.22 , pp. 1255-1257
    • Liu, K.1    Ferguson, S.M.2    Measures, R.M.3
  • 13
    • 0041009401 scopus 로고    scopus 로고
    • Acoustic emission source location using Lamb wave modes
    • Maji, A. K., Satapathi, D., and Kratochvil, T. (1997). ":Acoustic emission source location using Lamb wave modes.": J. Eng. Mech., 123(2), 154-161.
    • (1997) J. Eng. Mech. , vol.123 , Issue.2 , pp. 154-161
    • Maji, A.K.1    Satapathi, D.2    Kratochvil, T.3
  • 14
    • 0028754760 scopus 로고
    • Acoustic emission from reinforced concrete
    • Maji, A. K., and Shah, S. P. (1994). ":Acoustic emission from reinforced concrete.": Exp. Mech., 34(4), 379-388.
    • (1994) Exp. Mech. , vol.34 , Issue.4 , pp. 379-388
    • Maji, A.K.1    Shah, S.P.2
  • 15
    • 0032689211 scopus 로고    scopus 로고
    • Acoustic emission monitoring of hybrid FRP-concrete columns
    • Mirmiran, A., Shahawy, M., and Echary, H. E. (1999). ":Acoustic emission monitoring of hybrid FRP-concrete columns.": J. Eng. Mech., 125(8), 899-905.
    • (1999) J. Eng. Mech. , vol.125 , Issue.8 , pp. 899-905
    • Mirmiran, A.1    Shahawy, M.2    Echary, H.E.3
  • 16
    • 1642378351 scopus 로고
    • Ductility implications for prestressed and partially prestressed concrete structures using fiber reinforced plastic reinforcement
    • Prestressed Concrete Engineering Association, Kyoto, Japan
    • Naaman, A. E. (1993). ":Ductility implications for prestressed and partially prestressed concrete structures using fiber reinforced plastic reinforcement.": Modern prestressing techniques and their application, FIP'93 Symp., Prestressed Concrete Engineering Association, Kyoto, Japan, 757-766.
    • (1993) Modern Prestressing Techniques and Their Application, FIP'93 Symp. , pp. 757-766
    • Naaman, A.E.1
  • 17
    • 38149143160 scopus 로고
    • Tensile properties of hybrid rods for concrete reinforcement
    • Nanni, A., Henneke, M. J., and Okamoto, T. (1994). ":Tensile properties of hybrid rods for concrete reinforcement.": Constr. Build. Mater., 8(1), 27-34.
    • (1994) Constr. Build. Mater. , vol.8 , Issue.1 , pp. 27-34
    • Nanni, A.1    Henneke, M.J.2    Okamoto, T.3
  • 19
    • 0030243017 scopus 로고    scopus 로고
    • Surface bonded and embedded optical fibers as ultrasonic sensors
    • Pierce, S. G., Philip, W. R., Gachagan, A., McNab, A., Hayward, G., and Culshaw, B. (1996). ":Surface bonded and embedded optical fibers as ultrasonic sensors.": Appl. Opt., 35(25), 5191-5197.
    • (1996) Appl. Opt. , vol.35 , Issue.25 , pp. 5191-5197
    • Pierce, S.G.1    Philip, W.R.2    Gachagan, A.3    McNab, A.4    Hayward, G.5    Culshaw, B.6
  • 20
    • 0032206276 scopus 로고    scopus 로고
    • Ductile hybrid fiber reinforced plastic reinforcing bar for concrete structures: Design methodology
    • Somboonsong, W., Ko, F. K., and Harris, H. G. (1998). ":Ductile hybrid fiber reinforced plastic reinforcing bar for concrete structures: Design methodology.": ACI Mater. J., 95(6), 655-666.
    • (1998) ACI Mater. J. , vol.95 , Issue.6 , pp. 655-666
    • Somboonsong, W.1    Ko, F.K.2    Harris, H.G.3
  • 21
    • 3042703989 scopus 로고
    • Ductility of hybrid fiber composite reinforcement FRP for concrete
    • H. Saadatmanesh and M. R. Ehsani, eds., January 15-17, Univ. of Arizona, Tucson, Ariz.
    • Tamuzs, V., Tepfers, R., Apinis, R., Vilks, U., and Modniks, J. (1995). ":Ductility of hybrid fiber composite reinforcement FRP for concrete.": Proc., 1st Int. Conf. on Composites in Infrastructures, H. Saadatmanesh and M. R. Ehsani, eds., January 15-17, Univ. of Arizona, Tucson, Ariz., 110-121.
    • (1995) Proc., 1st Int. Conf. on Composites in Infrastructures , pp. 110-121
    • Tamuzs, V.1    Tepfers, R.2    Apinis, R.3    Vilks, U.4    Modniks, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.