메뉴 건너뛰기




Volumn 14, Issue 1 SUPPL., 2005, Pages S168-S173

Kinematics and constraint of total elbow arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

ARTHROPLASTY; CONFERENCE PAPER; ELBOW; HUMAN; JOINT FUNCTION; JOINT LAXITY; JOINT MOBILITY; JOINT PROSTHESIS; KINEMATICS; MUSCLE FORCE; PRIORITY JOURNAL; PROSTHESIS; PROSTHESIS FIXATION; PROSTHESIS LOOSENING;

EID: 13844321003     PISSN: 10582746     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jse.2004.09.035     Document Type: Conference Paper
Times cited : (33)

References (13)
  • 2
    • 0035351435 scopus 로고    scopus 로고
    • Role of collateral ligaments in the GSB-linked total elbow prosthesis
    • D.B. Herren, S.W. O'Driscoll, K.N. An Role of collateral ligaments in the GSB-linked total elbow prosthesis J Shoulder Elbow Surg 10 2001 260 264
    • (2001) J Shoulder Elbow Surg , vol.10 , pp. 260-264
    • Herren, D.B.1    O'Driscoll, S.W.2    An, K.N.3
  • 3
    • 0036301659 scopus 로고    scopus 로고
    • Importance of a radial head component in Sorbie unlinked total elbow arthroplasty
    • K. Inagaki, S.W. O'Driscoll, P.G. Neale Importance of a radial head component in Sorbie unlinked total elbow arthroplasty Clin Orthop 400 2002 123 131
    • (2002) Clin Orthop , vol.400 , pp. 123-131
    • Inagaki, K.1    O'Driscoll, S.W.2    Neale, P.G.3
  • 4
    • 0028500953 scopus 로고
    • Malrotation of the humeral component of the capitellocondylar total elbow replacement is not the sole cause of dislocation
    • E. Itoi, G.J. King, G.L. Neibur, B.F. Morrey, K.N. An Malrotation of the humeral component of the capitellocondylar total elbow replacement is not the sole cause of dislocation J Orthop Res 12 1994 665 671
    • (1994) J Orthop Res , vol.12 , pp. 665-671
    • Itoi, E.1    King, G.J.2    Neibur, G.L.3    Morrey, B.F.4    An, K.N.5
  • 5
    • 0027229919 scopus 로고
    • In vitro stability of an unconstrained total elbow prosthesis. Influence of axial loading and joint flexion angle
    • G.J. King, S.J. Glauser, A. Westreich, B.F. Morrey, K.N. An In vitro stability of an unconstrained total elbow prosthesis. Influence of axial loading and joint flexion angle J Arthroplasty 8 1993 291 298
    • (1993) J Arthroplasty , vol.8 , pp. 291-298
    • King, G.J.1    Glauser, S.J.2    Westreich, A.3    Morrey, B.F.4    An, K.N.5
  • 9
    • 0035208864 scopus 로고    scopus 로고
    • Treatment of instability after total elbow arthroplasty
    • S.W. O'Driscoll, G.J. King Treatment of instability after total elbow arthroplasty Orthop Clin North Am 32 2001 679 695
    • (2001) Orthop Clin North Am , vol.32 , pp. 679-695
    • O'Driscoll, S.W.1    King, G.J.2
  • 10
    • 0035211893 scopus 로고    scopus 로고
    • Contribution of monoblock and bipolar radial head prostheses to valgus stability of the elbow
    • S. Pomianowski, B.F. Morrey, P.G. Neale Contribution of monoblock and bipolar radial head prostheses to valgus stability of the elbow J Bone Joint Surg Am 83 2001 1829 1834
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 1829-1834
    • Pomianowski, S.1    Morrey, B.F.2    Neale, P.G.3
  • 11
    • 0042562188 scopus 로고    scopus 로고
    • Kinematics and functional characteristics of the Pritchard ERS unlinked total elbow arthroplasty
    • M. Ramsey, P.G. Neale, B.F. Morrey, S.W. O'Driscoll, K.N. An Kinematics and functional characteristics of the Pritchard ERS unlinked total elbow arthroplasty J Shoulder Elbow Surg 12 2003 385 390
    • (2003) J Shoulder Elbow Surg , vol.12 , pp. 385-390
    • Ramsey, M.1    Neale, P.G.2    Morrey, B.F.3    O'Driscoll, S.W.4    An, K.N.5
  • 12
    • 0034151081 scopus 로고    scopus 로고
    • Kinematics and laxity of the Souter-Strathclyde total elbow prosthesis
    • A.G. Schneeberger, G.J. King, S.W. Song Kinematics and laxity of the Souter-Strathclyde total elbow prosthesis J Shoulder Elbow Surg 9 2000 127 134
    • (2000) J Shoulder Elbow Surg , vol.9 , pp. 127-134
    • Schneeberger, A.G.1    King, G.J.2    Song, S.W.3
  • 13
    • 0029089828 scopus 로고
    • Loose-hinge total elbow arthroplasty. An experimental study of the effects of implant alignment on three-dimensional elbow kinematics
    • F. Schuind, S. O'Driscoll, S. Korinek, K.N. An, B.F. Morrey Loose-hinge total elbow arthroplasty. An experimental study of the effects of implant alignment on three-dimensional elbow kinematics J Arthroplasty 10 1995 670 678
    • (1995) J Arthroplasty , vol.10 , pp. 670-678
    • Schuind, F.1    O'Driscoll, S.2    Korinek, S.3    An, K.N.4    Morrey, B.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.