-
1
-
-
0021412692
-
Ferrocene-mediated enzyme electrode for amperometric determination of glucose
-
A.E.G Cass, G. Davis, G.D. Francis, H.A.O. Hill, W.J. Aston, I.J. Higgins, E.V. Plotkin, L.D.L. Scott, and A.P.F. Turner Ferrocene-mediated enzyme electrode for amperometric determination of glucose Anal. Chem. 56 1984 667 671
-
(1984)
Anal. Chem.
, vol.56
, pp. 667-671
-
-
Cass, E.G.1
Davis, G.2
Francis, G.D.3
Hill, H.A.O.4
Aston, W.J.5
Higgins, I.J.6
Plotkin, E.V.7
Scott, L.D.L.8
Turner, A.P.F.9
-
2
-
-
0000846408
-
Mediated amperometric biosensors for d-galactose, glycolate and l-amino acids based on a ferrocene-modified carbon paste electrode
-
J.M. Dicks, W.J. Aston, G. Davis, and A.P.F. Turner Mediated amperometric biosensors for d-galactose, glycolate and l-amino acids based on a ferrocene-modified carbon paste electrode Anal. Chim. Acta 182 1986 103 112
-
(1986)
Anal. Chim. Acta
, vol.182
, pp. 103-112
-
-
Dicks, J.M.1
Aston, W.J.2
Davis, G.3
Turner, A.P.F.4
-
3
-
-
0025231699
-
Mixed ferrocene-glucose oxidase-carbon paste electrode for an amperometric determination of glucose
-
J. Wang, L. Wu, W. Lu, R. Li, and J. Sanchez Mixed ferrocene-glucose oxidase-carbon paste electrode for an amperometric determination of glucose Anal. Chim. Acta 228 1990 251 257
-
(1990)
Anal. Chim. Acta
, vol.228
, pp. 251-257
-
-
Wang, J.1
Wu, L.2
Lu, W.3
Li, R.4
Sanchez, J.5
-
4
-
-
33845183900
-
A new class of amperometric biosensor incorporating a polymeric electron-transfer mediator
-
P.D. Hale, T. Inagaki, H.I. Karan, Y. Okamoto, and T.A. Skotheim A new class of amperometric biosensor incorporating a polymeric electron-transfer mediator J. Am. Chem. Soc. 111 1989 3482 3484
-
(1989)
J. Am. Chem. Soc.
, vol.111
, pp. 3482-3484
-
-
Hale, P.D.1
Inagaki, T.2
Karan, H.I.3
Okamoto, Y.4
Skotheim, T.A.5
-
5
-
-
0037437721
-
Electrodes modified with a siloxane copolymer containing interacting ferrocenes for determination of hydrogen peroxide and glucose
-
M.P.G. Armada, J. Losada, I. Cuadrado, B. Alonso, B. González, E. Ramírez-Oliva, and C.M. Casado Electrodes modified with a siloxane copolymer containing interacting ferrocenes for determination of hydrogen peroxide and glucose Sens. Actuators, B, Chem. 88 2003 190 197
-
(2003)
Sens. Actuators, B, Chem.
, vol.88
, pp. 190-197
-
-
Armada, M.P.G.1
Losada, J.2
Cuadrado, I.3
Alonso, B.4
González, B.5
Ramírez-Oliva, E.6
Casado, C.M.7
-
6
-
-
0033138389
-
Electrochemical characterizations of an enzyme electrode based on a ferrocene-containing redox polymer
-
S. Koide, and K.J. Yokoyama Electrochemical characterizations of an enzyme electrode based on a ferrocene-containing redox polymer J. Electroanal. Chem. 468 1999 193 201
-
(1999)
J. Electroanal. Chem.
, vol.468
, pp. 193-201
-
-
Koide, S.1
Yokoyama, K.J.2
-
7
-
-
0024110433
-
Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers
-
N.C. Foulds, and C. Lowe Immobilization of glucose oxidase in ferrocene-modified pyrrole polymers Anal. Chem. 60 1988 2473 2478
-
(1988)
Anal. Chem.
, vol.60
, pp. 2473-2478
-
-
Foulds, N.C.1
Lowe, C.2
-
8
-
-
0029232681
-
Amperometric detection of peroxides with poly(anilinomethylferrocene)- modified enzyme electrodes
-
A. Mulchandani, C.L. Wang, and H.H. Weetall Amperometric detection of peroxides with poly(anilinomethylferrocene)-modified enzyme electrodes Anal. Chem. 67 1995 94 100
-
(1995)
Anal. Chem.
, vol.67
, pp. 94-100
-
-
Mulchandani, A.1
Wang, C.L.2
Weetall, H.H.3
-
9
-
-
0000621451
-
Characterization of a ferrocene containing polyacrylamide-based redox gel for biosensor use
-
H.Z. Bu, S.R. Mikkelsen, and A.M. English Characterization of a ferrocene containing polyacrylamide-based redox gel for biosensor use Anal. Chem. 67 1995 4071 4076
-
(1995)
Anal. Chem.
, vol.67
, pp. 4071-4076
-
-
Bu, H.Z.1
Mikkelsen, S.R.2
English, A.M.3
-
10
-
-
37049068043
-
Enzyme catalysis at hydrogel-modified electrodes with redox polymer mediator
-
E.I. Calvo, C. Danilowicz, and L. Diaz Enzyme catalysis at hydrogel-modified electrodes with redox polymer mediator J. Chem. Soc., Faraday trans. 89 1993 377 384
-
(1993)
J. Chem. Soc., Faraday Trans.
, vol.89
, pp. 377-384
-
-
Calvo, E.I.1
Danilowicz, C.2
Diaz, L.3
-
11
-
-
0042029260
-
Preparation of novel redox copolymers: Poly[ferrocenylmethyl methacrylate-co-methoxy-oligo ethylene oxide) methacrylate], and their use as polymeric mediators in amperometric glucose sensors
-
H. Nagasaka, T. Saito, H. Hatakeyama, and M. Watanabe Preparation of novel redox copolymers: poly[ferrocenylmethyl methacrylate-co-methoxy-oligo ethylene oxide) methacrylate], and their use as polymeric mediators in amperometric glucose sensors Denki Kagaku 12 1995 1088 1094
-
(1995)
Denki Kagaku
, vol.12
, pp. 1088-1094
-
-
Nagasaka, H.1
Saito, T.2
Hatakeyama, H.3
Watanabe, M.4
-
12
-
-
0032099294
-
Characterization of poly(vinylferrocene-co-2 hydroxyethyl methacrylate) for use as electron mediator in enzymatic glucose sensor
-
T. Saito, and M. Watanabe Characterization of poly(vinylferrocene-co-2 hydroxyethyl methacrylate) for use as electron mediator in enzymatic glucose sensor React. Funct. Polym. 37 1998 263 269
-
(1998)
React. Funct. Polym.
, vol.37
, pp. 263-269
-
-
Saito, T.1
Watanabe, M.2
-
13
-
-
0035850545
-
Assessing a photocured self-plasticised acrylic membrane recipe for Na+ and K+ ion selective electrodes
-
L.Y. Heng, and E.A.H. Hall Assessing a photocured self-plasticised acrylic membrane recipe for Na+ and K+ ion selective electrodes Anal. Chim. Acta 443 2001 25 40
-
(2001)
Anal. Chim. Acta
, vol.443
, pp. 25-40
-
-
Heng, L.Y.1
Hall, E.A.H.2
-
14
-
-
0002797481
-
Producing "self-plasticizing" ion-selective membranes
-
L.Y. Heng, and E.A.H. Hall Producing "self-plasticizing" ion-selective membranes Anal. Chem. 72 2000 42 51
-
(2000)
Anal. Chem.
, vol.72
, pp. 42-51
-
-
Heng, L.Y.1
Hall, E.A.H.2
-
15
-
-
0345352783
-
Covalent immobilisation of invertase onto a reactive film composed of 2-hydroxyethyl methacrylate and glycidyl methacrylate: Properties and application in a continuous flow system
-
G. Bayramoblu, S. Akgöl, A. Bulut, A. Denizli, and M.Y. Arica Covalent immobilisation of invertase onto a reactive film composed of 2-hydroxyethyl methacrylate and glycidyl methacrylate: properties and application in a continuous flow system Biochem. Eng. J. 14 2003 117 126
-
(2003)
Biochem. Eng. J.
, vol.14
, pp. 117-126
-
-
Bayramoblu, G.1
Akgöl, S.2
Bulut, A.3
Denizli, A.4
Arica, M.Y.5
-
17
-
-
0031140907
-
A miniaturized glucose biosensor based on the coimmobilization of glucose oxidase and ferrocene perchlorate in nafion at a microdisk platinum electrode
-
D.M. Zhou, H.X. Ju, and H.Y. Chen A miniaturized glucose biosensor based on the coimmobilization of glucose oxidase and ferrocene perchlorate in nafion at a microdisk platinum electrode Sens. Actuators, B, Chem. 40 1997 89 94
-
(1997)
Sens. Actuators, B, Chem.
, vol.40
, pp. 89-94
-
-
Zhou, D.M.1
Ju, H.X.2
Chen, H.Y.3
|