1
-
-
0026868850
-
Influence of CRT workstation on observer's performance
-
Y. Itoh, T. Ishigaki, S. Sakuma, M. Hirose, H. Fukatsu, and S. Itoh Influence of CRT workstation on observer's performance Comput Meth Programs Biomed 37 4 1992 253 258
-
(1992)
Comput Meth Programs Biomed
, vol.37
, Issue.4
, pp. 253-258
-
-
Itoh, Y.1
Ishigaki, T.2
Sakuma, S.3
Hirose, M.4
Fukatsu, H.5
Itoh, S.6
-
2
-
-
0031867498
-
Comparison of a cathode-ray-tube and film for display of computed radiographic images
-
L.T. Cook, G.G. Cox, M.F. Insana, M.A. McFadden, T.J. Hall, R.S. Gaborski, and F.Y. Lure Comparison of a cathode-ray-tube and film for display of computed radiographic images Med Phys 25 7 Pt 1 1998 1132 1138
-
(1998)
Med Phys
, vol.25
, Issue.7 PART 1
, pp. 1132-1138
-
-
Cook, L.T.1
Cox, G.G.2
Insana, M.F.3
McFadden, M.A.4
Hall, T.J.5
Gaborski, R.S.6
Lure, F.Y.7
-
3
-
-
0033228448
-
High-fidelity electronic display of digital radiographs
-
M.J. Flynn, J. Kanicki, A. Badano, and W.R. Eyler High-fidelity electronic display of digital radiographs Radiographics 19 6 1999 1653 1669
-
(1999)
Radiographics
, vol.19
, Issue.6
, pp. 1653-1669
-
-
Flynn, M.J.1
Kanicki, J.2
Badano, A.3
Eyler, W.R.4
-
4
-
-
0033277470
-
Influence of film and monitor display luminance on observer performance and visual search
-
E. Krupinski, H. Roehrig, and T. Furukawa Influence of film and monitor display luminance on observer performance and visual search Acad Radiol 6 7 1999 411 418
-
(1999)
Acad Radiol
, vol.6
, Issue.7
, pp. 411-418
-
-
Krupinski, E.1
Roehrig, H.2
Furukawa, T.3
-
5
-
-
0034435345
-
The influence of a perceptually linearized display on observer performance and visual search
-
E.A. Krupinski, and H. Roehrig The influence of a perceptually linearized display on observer performance and visual search Acad Radiol 7 1 2000 8 13
-
(2000)
Acad Radiol
, vol.7
, Issue.1
, pp. 8-13
-
-
Krupinski, E.A.1
Roehrig, H.2
-
6
-
-
0035345373
-
Cathode ray tube quality control and acceptance testing program: Initial results for clinical PACS displays
-
D.S. Groth, S.N. Bernatz, K.A. Fetterly, and N.J. Hangiandreou Cathode ray tube quality control and acceptance testing program: initial results for clinical PACS displays Radiographics 21 3 2001 719 732
-
(2001)
Radiographics
, vol.21
, Issue.3
, pp. 719-732
-
-
Groth, D.S.1
Bernatz, S.N.2
Fetterly, K.A.3
Hangiandreou, N.J.4
-
7
-
-
0037029058
-
CRT diagnosis of pulmonary disease: Influence of monitor brightness and room illuminance on observer performance
-
S. Ishihara, K. Shimamoto, M. Ikeda, K. Kato, Y. Mori, and T. Ishiguchi CRT diagnosis of pulmonary disease: influence of monitor brightness and room illuminance on observer performance Comput Med Imaging Graph 26 3 2002 181 185
-
(2002)
Comput Med Imaging Graph
, vol.26
, Issue.3
, pp. 181-185
-
-
Ishihara, S.1
Shimamoto, K.2
Ikeda, M.3
Kato, K.4
Mori, Y.5
Ishiguchi, T.6
-
8
-
-
0037231261
-
Influence of monitor luminance change on observer performance for detection of abnormalities depicted on chest radiographs
-
M. Ikeda, T. Ishigaki, K. Shimamoto, Y. Kodera, S. Koyama, and H. Usami Influence of monitor luminance change on observer performance for detection of abnormalities depicted on chest radiographs Invest Radiol 38 1 2003 57 63
-
(2003)
Invest Radiol
, vol.38
, Issue.1
, pp. 57-63
-
-
Ikeda, M.1
Ishigaki, T.2
Shimamoto, K.3
Kodera, Y.4
Koyama, S.5
Usami, H.6
-
9
-
-
0001074814
-
Quantitative image quality studies and the design of X-ray fluoroscopy systems
-
J. Beutel H.L. Kundel R.L.V. Metter Handbook of medical imaging SPIE Press Bellingham, Washington
-
D.L. Wilson, K.N. Jabri, and R.M. Manjeshwar Quantitative image quality studies and the design of X-ray fluoroscopy systems J. Beutel H.L. Kundel R.L.V. Metter Handbook of medical imaging Physics and psychophysics vol. 1 2000 SPIE Press Bellingham, Washington 721 750
-
(2000)
Physics and Psychophysics
, vol.1
, pp. 721-750
-
-
Wilson, D.L.1
Jabri, K.N.2
Manjeshwar, R.M.3
-
10
-
-
0032129254
-
Quantitative evaluation of overall electronic display quality
-
N.J. Hangiandreou, K.A. Fetterly, S.N. Bernatz, L.J. Cesar, D.S. Groth, and J.P. Felmlee Quantitative evaluation of overall electronic display quality J Digit Imaging 11 3 Suppl. 1 1998 180 186
-
(1998)
J Digit Imaging
, vol.11
, Issue.3 SUPPL. 1
, pp. 180-186
-
-
Hangiandreou, N.J.1
Fetterly, K.A.2
Bernatz, S.N.3
Cesar, L.J.4
Groth, D.S.5
Felmlee, J.P.6
-
11
-
-
0032588496
-
Optimization of a contrast-detail-based method for electronic image display quality evaluation
-
N.J. Hangiandreou, K.A. Fetterly, and J.P. Felmlee Optimization of a contrast-detail-based method for electronic image display quality evaluation J Digit Imaging 12 2 1999 60 67
-
(1999)
J Digit Imaging
, vol.12
, Issue.2
, pp. 60-67
-
-
Hangiandreou, N.J.1
Fetterly, K.A.2
Felmlee, J.P.3
-
12
-
-
0032748266
-
Detection of subtle lung nodules: Relative influence of quantum and anatomic noise on chest radiographs
-
E. Samei, M.J. Flynn, and W.R. Eyler Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs Radiology 213 3 1999 727 734
-
(1999)
Radiology
, vol.213
, Issue.3
, pp. 727-734
-
-
Samei, E.1
Flynn, M.J.2
Eyler, W.R.3
-
13
-
-
0026664983
-
Receiver operating characteristic rating analysis. Generalization to the population of readers and patients with the jackknife method
-
D.D. Dorfman, K.S. Berbaum, and C.E. Metz Receiver operating characteristic rating analysis. Generalization to the population of readers and patients with the jackknife method Invest Radiol 27 9 1992 723 731
-
(1992)
Invest Radiol
, vol.27
, Issue.9
, pp. 723-731
-
-
Dorfman, D.D.1
Berbaum, K.S.2
Metz, C.E.3
|