Volumn 130, Issue 11, 2004, Pages 1820-1828

Fire resistance of reinforced concrete columns subjected to 1-, 2-, and 3-face heating

Author keywords

Columns; Concrete, reinforced; Fire resistance; Heating

Indexed keywords

NONSYMMETRIC HEATING; REDUCTION FACTORS; REINFORCED CONCRETE (RC) COLUMNS; UNIAXIAL BENDING;

EID: 13844256322     PISSN: 07339445     EISSN: None     Source Type: Journal    
DOI: 10.1061/(ASCE)0733-9445(2004)130:11(1820)     Document Type: Article
Times cited : (60)

References (17)
  • 1
    • 67649126859 scopus 로고
    • State-of-the art report on high-strength concrete
    • Farmington Hills, Mich
    • American Concrete Institute (ACI). (1992). "State-of-the art report on high-strength concrete." ACI Committee Rep. 363R-92, Farmington Hills, Mich.
    • (1992) ACI Committee Rep. , vol.363 R-92
  • 2
    • 13844251830 scopus 로고    scopus 로고
    • Building code requirement for reinforced concrete, Part 3: Use of concrete in buildings - Design, specification, and related topics
    • ACI Manual of Concrete Practice, Detroit
    • American Concrete Institute (ACI). (2000). "Building code requirement for reinforced concrete, Part 3: Use of concrete in buildings - Design, specification, and related topics." ACI Committee Rep. 318-99, ACI Manual of Concrete Practice, Detroit.
    • (2000) ACI Committee Rep. , vol.318 , Issue.99
  • 3
    • 13844289168 scopus 로고
    • Predicted fire behaviour of steels and concrete structures
    • Division of Building Fire Safety and Technology, Lund Institute of Technology, Lund, Sweden
    • Anderberg, Y. (1983). "Predicted fire behaviour of steels and concrete structures." Rep. LUTVDG/(TVBB-3011), Division of Building Fire Safety and Technology, Lund Institute of Technology, Lund, Sweden.
    • (1983) Rep. LUTVDG/(TVBB-3011)
    • Anderberg, Y.1
  • 4
    • 0000824768 scopus 로고
    • Design criteria for reinforced columns under axial load bi-axial bending
    • Bresler, B. (1960). "Design criteria for reinforced columns under axial load bi-axial bending." J. Am. Conor. Inst., 57(5), 481-491.
    • (1960) J. Am. Conor. Inst. , vol.57 , Issue.5 , pp. 481-491
    • Bresler, B.1
  • 5
    • 0028132397 scopus 로고
    • A simple approach to the behavior of steel columns in fire
    • Burgess, I. W., and Najjar, S. R. (1994). "A simple approach to the behavior of steel columns in fire." J. Constr. Steel Res., 31, 155-134.
    • (1994) J. Constr. Steel Res. , vol.31 , pp. 155-1134
    • Burgess, I.W.1    Najjar, S.R.2
  • 6
    • 0031166457 scopus 로고    scopus 로고
    • Experimental research on the determination of the main parameters affecting the behavior of reinforced concrete columns under fire conditions
    • Dotreppe, J. C., et al. (1997). "Experimental research on the determination of the main parameters affecting the behavior of reinforced concrete columns under fire conditions." Mag. Concrete Res., 49(179), 117-127.
    • (1997) Mag. Concrete Res. , vol.49 , Issue.179 , pp. 117-127
    • Dotreppe, J.C.1
  • 7
    • 0032681747 scopus 로고    scopus 로고
    • Calculation method for design of reinforced concrete columns under fire conditions
    • Dotreppe, J. C., Franssen, J. M., and Vanderzeypen, Y. (1999). "Calculation method for design of reinforced concrete columns under fire conditions." ACI Struct. J., 96(1), 9-18.
    • (1999) ACI Struct. J. , vol.96 , Issue.1 , pp. 9-18
    • Dotreppe, J.C.1    Franssen, J.M.2    Vanderzeypen, Y.3
  • 8
    • 13844269054 scopus 로고
    • Design of concrete structure. Part 1.2: General rules - Structural fire design, ENV 1992-1-2
    • European Committee for Standardization. (1995). "Design of concrete structure. Part 1.2: General rules - Structural fire design, ENV 1992-1-2. " Eurocode 2.
    • (1995) Eurocode 2
  • 9
    • 1642277458 scopus 로고    scopus 로고
    • Civil and Structural Engineering Department, University of Liege, Belgium
    • Franssen, J. M. (1999). Manual of SAFIR, Civil and Structural Engineering Department, University of Liege, Belgium.
    • (1999) Manual of SAFIR
    • Franssen, J.M.1
  • 10
    • 85013909614 scopus 로고
    • A comprehensive creep model
    • ASME
    • Harmarthy, T. Z. (1967). "A comprehensive creep model." J. Basis Eng. Trans., ASME, 396-502.
    • (1967) J. Basis Eng. Trans. , pp. 396-502
    • Harmarthy, T.Z.1
  • 11
    • 0041535704 scopus 로고
    • Practical rules for the design of reinforced concrete and composite columns submitted to fire
    • Institute für Baustoffe, Massivbau und Brandschutz der Technischen Universitä Braunschweig
    • Hass, R. (1986). "Practical rules for the design of reinforced concrete and composite columns submitted to fire." Technical Rep. No. 69, Institute für Baustoffe, Massivbau und Brandschutz der Technischen Universitä Braunschweig.
    • (1986) Technical Rep. No. 69 , vol.69
    • Hass, R.1
  • 12
    • 10844237710 scopus 로고
    • Simplified calculation method for fire exposed concrete structures
    • Technical University of Denmak, Lyngby, Denmark
    • Hertz, K. (1993). "Simplified calculation method for fire exposed concrete structures." Supporting document for CEN pr-ENV 1992-1-2, Technical University of Denmak, Lyngby, Denmark.
    • (1993) Supporting Document for CEN Pr-ENV 1992-1-2
    • Hertz, K.1
  • 13
    • 0041535706 scopus 로고
    • Fire resistance of reinforced concrete columns: Test results
    • National Research Council Canada
    • Lie, T. T., and Woollerton, J. L. (1988). "Fire resistance of reinforced concrete columns: Test results." Internal Rep. No. 569, National Research Council Canada.
    • (1988) Internal Rep. No. 569 , vol.569
    • Lie, T.T.1    Woollerton, J.L.2
  • 15
    • 10844228256 scopus 로고    scopus 로고
    • Fire resistance of four-face heated reinforced concrete columns
    • Tan, K. H., and Yao, Y. (2003). "Fire resistance of four-face heated reinforced concrete columns." J. Struct. Eng., 129(9), 1220-1229.
    • (2003) J. Struct. Eng. , vol.129 , Issue.9 , pp. 1220-1229
    • Tan, K.H.1    Yao, Y.2
  • 16
    • 0035483334 scopus 로고    scopus 로고
    • Basis and application of a simple interaction formula for steel columns under fire conditions
    • Tang, C. Y., Tan, K. H., and Ting, S. K. (2001). "Basis and application of a simple interaction formula for steel columns under fire conditions." J. Struct. Eng., 127(10), 1206-1213.
    • (2001) J. Struct. Eng. , vol.127 , Issue.10 , pp. 1206-1213
    • Tang, C.Y.1    Tan, K.H.2    Ting, S.K.3
  • 17
    • 0030718148 scopus 로고    scopus 로고
    • The effects of frame continuity on the behavior of steel columns under fire conditions and fire resistance design proposals
    • Wang, Y. C. (1997). "The effects of frame continuity on the behavior of steel columns under fire conditions and fire resistance design proposals." J. Constr. Steel Res., 41(1), 93-111.
    • (1997) J. Constr. Steel Res. , vol.41 , Issue.1 , pp. 93-111
    • Wang, Y.C.1