Volumn 28, Issue 5, 2004, Pages 275-280

Estimation of breast prosthesis volume by the Cavalieri principle using magnetic resonance images

Author keywords

Breast prosthesis; Cavalieri principle; MR imaging; Stereology; Volume estimation

Indexed keywords

ACCURACY; ARTICLE; BREAST PROSTHESIS; CAVALIERI METHOD; COMPUTER PROGRAM; MATHEMATICAL ANALYSIS; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; REPRODUCIBILITY; TECHNIQUE;

EID: 13644266921     PISSN: 0364216X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00266-004-0022-8     Document Type: Article
Times cited : (39)

References (33)
  • 1
    • 0345647084 scopus 로고    scopus 로고
    • Lipid infiltration as a possible biologic cause of silicone gel breast implant aging
    • Adams WP, Robinson JB, Rohrich RJ: Lipid infiltration as a possible biologic cause of silicone gel breast implant aging. Plast Reconstr Surg 101:69-71, 1998
    • (1998) Plast Reconstr Surg , vol.101 , pp. 69-71
    • Adams, W.P.1    Robinson, J.B.2    Rohrich, R.J.3
  • 2
    • 0031696354 scopus 로고    scopus 로고
    • Imaging signs and radiologist's jargon of ruptured breast implants
    • Beekman WH, Van SWR, Hage JJ, Mulder JW: Imaging signs and radiologist's jargon of ruptured breast implants. Plast Reconstr Surg 102:1281-1289, 1998
    • (1998) Plast Reconstr Surg , vol.102 , pp. 1281-1289
    • Beekman, W.H.1    Van, S.W.R.2    Hage, J.J.3    Mulder, J.W.4
  • 4
    • 0036249936 scopus 로고    scopus 로고
    • In vivo aging characteristics of silicone gel breast implants compared to lot-matched controls
    • Brandom HJ, Jerina KL, Wolf CJ, Young WL: In vivo aging characteristics of silicone gel breast implants compared to lot-matched controls. Plast Reconstr Surg 109:1927-1933, 2002
    • (2002) Plast Reconstr Surg , vol.109 , pp. 1927-1933
    • Brandom, H.J.1    Jerina, K.L.2    Wolf, C.J.3    Young, W.L.4
  • 5
    • 0033796965 scopus 로고    scopus 로고
    • Prevalence of rupturing of silicon gel implants revealed on MR imaging in a population of women in Birmingham, Alabama
    • Brown SL, Middleton MS, Berg WA, Soo MS, Pennello G: Prevalence of rupturing of silicon gel implants revealed on MR imaging in a population of women in Birmingham, Alabama. AJR Am J Roentgenol 175:1057-1064, 2000
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 1057-1064
    • Brown, S.L.1    Middleton, M.S.2    Berg, W.A.3    Soo, M.S.4    Pennello, G.5
  • 6
    • 0031022417 scopus 로고    scopus 로고
    • The efficient calculation of neurosurgically relevant volumes from computed tomographic scans using Cavalieri's direct estimator
    • Clatterbuck RE, Sipos EP: The efficient calculation of neurosurgically relevant volumes from computed tomographic scans using Cavalieri's direct estimator. Neurosurgery 40:339-342, 1997
    • (1997) Neurosurgery , vol.40 , pp. 339-342
    • Clatterbuck, R.E.1    Sipos, E.P.2
  • 7
    • 0023111176 scopus 로고
    • Particle number can be estimated using a dissector of unknown thickness: The selector
    • Cruz-Orive LM: Particle number can be estimated using a dissector of unknown thickness: The selector. J Microsc 145:121-142, 1987
    • (1987) J Microsc , vol.145 , pp. 121-142
    • Cruz-Orive, L.M.1
  • 9
    • 0026823462 scopus 로고
    • Augmentation mammoplasty: Normal and abnormal findings with mammography and US
    • Ganott MA, Harris KM, Ilkhanipour ZS, Costa-Greco MA: Augmentation mammoplasty: Normal and abnormal findings with mammography and US. Radiographics 12:281-295, 1992
    • (1992) Radiographics , vol.12 , pp. 281-295
    • Ganott, M.A.1    Harris, K.M.2    Ilkhanipour, Z.S.3    Costa-Greco, M.A.4
  • 10
    • 0019417195 scopus 로고
    • Comparison of semiautomatic digitizer tablet and simple point-counting performance in morphometry
    • Gundersen HJG, Boysen M, Reith A: Comparison of semiautomatic digitizer tablet and simple point-counting performance in morphometry. Virchows Arch B Cell Pathol Incl Mol Pathol 37:317-325, 1981
    • (1981) Virchows Arch B Cell Pathol Incl Mol Pathol , vol.37 , pp. 317-325
    • Gundersen, H.J.G.1    Boysen, M.2    Reith, A.3
  • 11
    • 84985280160 scopus 로고
    • The efficiency of systematic sampling in stereology and its prediction
    • Gundersen HJG, Jensen EB: The efficiency of systematic sampling in stereology and its prediction. J Microsc 147:229-263, 1987
    • (1987) J Microsc , vol.147 , pp. 229-263
    • Gundersen, H.J.G.1    Jensen, E.B.2
  • 12
    • 0033063695 scopus 로고    scopus 로고
    • Estimation of breast volume and its variation during the menstrual cycle using MRI and stereology
    • Hussain Z, Roberts N, Whitehouse GH, García-Fiñana M, Percy D: Estimation of breast volume and its variation during the menstrual cycle using MRI and stereology. Br J Radiol 72:236-245, 1999
    • (1999) Br J Radiol , vol.72 , pp. 236-245
    • Hussain, Z.1    Roberts, N.2    Whitehouse, G.H.3    García-Fiñana, M.4    Percy, D.5
  • 13
    • 0022000378 scopus 로고
    • Xeromammography after augmentation mammoplasty
    • Jensen SR, Mackey JK: Xeromammography after augmentation mammoplasty. AJR Am J Roentgenol 144:629-633, 1985
    • (1985) AJR Am J Roentgenol , vol.144 , pp. 629-633
    • Jensen, S.R.1    Mackey, J.K.2
  • 15
    • 0028050203 scopus 로고
    • The role of ultrasound imaging in the diagnosis of breast implant: A prospective study
    • Liston JC, Malata CM, Varma MS, Sharpe DT: The role of ultrasound imaging in the diagnosis of breast implant: A prospective study. Br J Plast Surg 47:477-482, 1994
    • (1994) Br J Plast Surg , vol.47 , pp. 477-482
    • Liston, J.C.1    Malata, C.M.2    Varma, M.S.3    Sharpe, D.T.4
  • 16
    • 0006341147 scopus 로고    scopus 로고
    • Comparison of compartment volumes estimated from MR images and physical sections of formalin fixed cerebral hemispheres
    • Mackay CE, Pakkenberg B, Roberts N: Comparison of compartment volumes estimated from MR images and physical sections of formalin fixed cerebral hemispheres. Acta Stereol 18:149-159, 1999
    • (1999) Acta Stereol , vol.18 , pp. 149-159
    • Mackay, C.E.1    Pakkenberg, B.2    Roberts, N.3
  • 17
    • 0019483134 scopus 로고
    • Measuring error and sampling variation in stereology: Comparison of the efficiency of various methods of planar image analysis
    • Mathieu O, Cruz-Orive LM, Hoppeler H, Weibel ER: Measuring error and sampling variation in stereology: Comparison of the efficiency of various methods of planar image analysis. J Microsc 121:75-88, 1981
    • (1981) J Microsc , vol.121 , pp. 75-88
    • Mathieu, O.1    Cruz-Orive, L.M.2    Hoppeler, H.3    Weibel, E.R.4
  • 18
    • 0025995529 scopus 로고
    • Magnetic resonance imaging (MRI) and model free estimates of brain volumes determined using the Cavalieri principle
    • Mayhew TM, Olsen DR: Magnetic resonance imaging (MRI) and model free estimates of brain volumes determined using the Cavalieri principle. J Anat 178:133-114, 1991
    • (1991) J Anat , vol.178 , pp. 133-1114
    • Mayhew, T.M.1    Olsen, D.R.2
  • 20
    • 0344494539 scopus 로고    scopus 로고
    • Rapid estimation of the vertebral body volume: A combination of the Cavalieri principle and computed tomography images
    • Odaci E, Sahin B, Sonmez OF, Kaplan S, Bas O, Bilgic S, Bek Y, Ergür H: Rapid estimation of the vertebral body volume: A combination of the Cavalieri principle and computed tomography images. Eur J Radiol 48:316-326, 2003
    • (2003) Eur J Radiol , vol.48 , pp. 316-326
    • Odaci, E.1    Sahin, B.2    Sonmez, O.F.3    Kaplan, S.4    Bas, O.5    Bilgic, S.6    Bek, Y.7    Ergür, H.8
  • 21
    • 0026726999 scopus 로고
    • Stereological quantitation of human brains from normal and schizophrenic individuals
    • Pakkenberg B: Stereological quantitation of human brains from normal and schizophrenic individuals. Acta Neurol Scand 137:20-33, 1992
    • (1992) Acta Neurol Scand , vol.137 , pp. 20-33
    • Pakkenberg, B.1
  • 22
    • 0024469892 scopus 로고
    • Unbiased and efficient estimation of total ventricular volume of the brain obtained from CT scans by a stereological method
    • Pakkenberg B, Boesen J, Albeck M, Gjerris F: Unbiased and efficient estimation of total ventricular volume of the brain obtained from CT scans by a stereological method. Neuroradiology 31:413-417, 1989
    • (1989) Neuroradiology , vol.31 , pp. 413-417
    • Pakkenberg, B.1    Boesen, J.2    Albeck, M.3    Gjerris, F.4
  • 24
    • 0024342953 scopus 로고
    • Optimizing sample design for volume measurement of components of human brain using a stereological method
    • Regeur L, Pakkenberg B: Optimizing sample design for volume measurement of components of human brain using a stereological method. J Microsc 155:113-121, 1989
    • (1989) J Microsc , vol.155 , pp. 113-121
    • Regeur, L.1    Pakkenberg, B.2
  • 25
    • 0027422570 scopus 로고
    • Unbiased estimation of human body composition by the Cavalieri method using magnetic resonance imaging
    • Roberts N, Cruz-Orive LM, Reid NMK, Brodie DA, Bourne M, Edwards RHT: Unbiased estimation of human body composition by the Cavalieri method using magnetic resonance imaging. J Microsc 171:239-253, 1992
    • (1992) J Microsc , vol.171 , pp. 239-253
    • Roberts, N.1    Cruz-Orive, L.M.2    Reid, N.M.K.3    Brodie, D.A.4    Bourne, M.5    Edwards, R.H.T.6
  • 27
    • 13644263018 scopus 로고
    • Analysis of explanted silicon implants: A report of 300 patients
    • Robinson OG, Bradley EL, Wilson DS: Analysis of explanted silicon implants: A report of 300 patients. Ann Plast Surg 1:34-39, 1995
    • (1995) Ann Plast Surg , vol.1 , pp. 34-39
    • Robinson, O.G.1    Bradley, E.L.2    Wilson, D.S.3
  • 29
    • 0002645569 scopus 로고    scopus 로고
    • Brain volumes of the lamb, rat, and bird do not show hemispheric asymmetry: A stereological study
    • Sahin B, Aslan H, Unal B, Canan S, Bilgic S, Kaplan S, Tumkaya L: Brain volumes of the lamb, rat, and bird do not show hemispheric asymmetry: A stereological study. Image Anal Stereol 20:9-13, 2001
    • (2001) Image Anal Stereol , vol.20 , pp. 9-13
    • Sahin, B.1    Aslan, H.2    Unal, B.3    Canan, S.4    Bilgic, S.5    Kaplan, S.6    Tumkaya, L.7
  • 30
    • 0042669891 scopus 로고    scopus 로고
    • Unbiased estimation of the liver volume by the Cavalieri principle using magnetic resonance images
    • Sahin B, Emirzeoglu M, Uzun A, Incesu L, Bek Y, Bilgic S, Kaplan S: Unbiased estimation of the liver volume by the Cavalieri principle using magnetic resonance images. Eur J Radiol 47:164-170, 2003
    • (2003) Eur J Radiol , vol.47 , pp. 164-170
    • Sahin, B.1    Emirzeoglu, M.2    Uzun, A.3    Incesu, L.4    Bek, Y.5    Bilgic, S.6    Kaplan, S.7
  • 32
    • 0343415734 scopus 로고    scopus 로고
    • Spontaneous auto inflation of saline-filled mammary implants: Postoperative volume determination by magnetic resonance imaging
    • Tuncali D, Ozgur F: Spontaneous auto inflation of saline-filled mammary implants: Postoperative volume determination by magnetic resonance imaging. Aesth Plast Surg 23:437-442, 1999
    • (1999) Aesth Plast Surg , vol.23 , pp. 437-442
    • Tuncali, D.1    Ozgur, F.2
  • 33
    • 0029004645 scopus 로고
    • A characteristic ventricular shape in myelenmeningocele associated hydrocephalus? A CT stereology study
    • Van Roost D, Solymosi L, Funlce K: A characteristic ventricular shape in myelenmeningocele associated hydrocephalus? A CT stereology study. Neuroradiology 37:412-417, 1995
    • (1995) Neuroradiology , vol.37 , pp. 412-417
    • Van Roost, D.1    Solymosi, L.2    Funlce, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.