1
-
-
0003731071
-
Cavitation
-
Iowa City, IA, USA: Institute of Hydraulic Research, University of Iowa
-
Knapp RT, Daily JW, Hammitt FG. Cavitation. Iowa City, IA, USA: Institute of Hydraulic Research, University of Iowa, 1979; 221-3.
-
(1979)
, pp. 221-223
-
-
Knapp, R.T.1
Daily, J.W.2
Hammitt, F.G.3
-
2
-
-
0024495078
-
Leaflet fracture in Edward-Duromedics bileaflet valves
-
Klepetko W, Moritz A, Mlczoch J, Schurawitzki H, Domanig E, Wolner E. Leaflet fracture in Edward-Duromedics bileaflet valves. J Thorac Cardiovasc Surg 1989; 97: 90-4.
-
(1989)
J. Thorac. Cardiovasc. Surg.
, vol.97
, pp. 90-94
-
-
Klepetko, W.1
Moritz, A.2
Mlczoch, J.3
Schurawitzki, H.4
Domanig, E.5
Wolner, E.6
-
3
-
-
0028231956
-
Cavitation damage of pyrolytic carbon in mechanical heart valves
-
Kafesjian R, Howanec M, Ward GD, et al. Cavitation damage of pyrolytic carbon in mechanical heart valves. J Heart Valve Dis 1994; 3 (suppl 1): S2-7.
-
(1994)
J. Heart Valve Dis.
, vol.3
, Issue.SUPPL. 1
-
-
Kafesjian, R.1
Howanec, M.2
Ward, G.D.3
-
4
-
-
0026911181
-
Cavitation at mechanical heart valves under simulated physiological conditions
-
Graf T, Reul H, Dietz W, Wilmes R, Rau G. Cavitation at mechanical heart valves under simulated physiological conditions. J Heart Valve Dis 1992; 1: 131-41.
-
(1992)
J. Heart Valve Dis.
, vol.1
, pp. 131-141
-
-
Graf, T.1
Reul, H.2
Dietz, W.3
Wilmes, R.4
Rau, G.5
-
5
-
-
0028333976
-
An in vitro investigation of prosthetic heart valve cavitation in blood
-
Garrison LA, Lamson TC, Deutsch S, Geselowitz DB, Gaumond RP, Tarbell JM. An in vitro investigation of prosthetic heart valve cavitation in blood. J Heart Valve Dis 1994; 3 (suppl 1): S8-24.
-
(1994)
J. Heart Valve Dis.
, vol.3
, Issue.SUPPL. 1
-
-
Garrison, L.A.1
Lamson, T.C.2
Deutsch, S.3
Geselowitz, D.B.4
Gaumond, R.P.5
Tarbell, J.M.6
-
6
-
-
0028216521
-
Causes and formation of cavitation in mechanical heart valve
-
Graf T, Reul H, Detlefs C, Wilmes R, Rau G. Causes and formation of cavitation in mechanical heart valve. J Heart Valve Dis 1994; 3 (suppl 1): S49-64.
-
(1994)
J. Heart Valve Dis.
, vol.3
, Issue.SUPPL. 1
-
-
Graf, T.1
Reul, H.2
Detlefs, C.3
Wilmes, R.4
Rau, G.5
-
8
-
-
0028287316
-
In vitro observations of mechanical heart valve cavitation
-
Shu MCS, Leuer LH, Armitage TL, Schneider TE, Christiansen DR. In vitro observations of mechanical heart valve cavitation. Heart Valve Dis 1994; 3 (suppl 1): S85-93.
-
(1994)
Heart Valve Dis.
, vol.3
, Issue.SUPPL. 1
-
-
Shu, M.C.S.1
Leuer, L.H.2
Armitage, T.L.3
Schneider, T.E.4
Christiansen, D.R.5
-
9
-
-
0030023102
-
Effect of valve holder flexibility on cavitation initiation with mechanical heart valve prostheses: An in vitro study
-
Lee CS, Aluri S, Chandran KB. Effect of valve holder flexibility on cavitation initiation with mechanical heart valve prostheses: An in vitro study. J Heart Valve Dis 1996; 5: 104-13.
-
(1996)
J. Heart Valve Dis.
, vol.5
, pp. 104-113
-
-
Lee, C.S.1
Aluri, S.2
Chandran, K.B.3
-
10
-
-
0034793868
-
Mechanisms of mechanical heart valve cavitation: Investigation using a tilting disk valve model
-
He Z, Xi B, Zhu K, Hwang NHC. Mechanisms of mechanical heart valve cavitation: Investigation using a tilting disk valve model. J Heart Valve Dis 2001; 10: 666-74.
-
(2001)
J. Heart Valve Dis.
, vol.10
, pp. 666-674
-
-
He, Z.1
Xi, B.2
Zhu, K.3
Hwang, N.H.C.4
-
11
-
-
0034566379
-
Surface pitting of heart valve disks tested in an accelerated fatigue tester
-
Lee HS, Shimooka T, Mitamura Y, Yamamoto K, Yuhta T. Surface pitting of heart valve disks tested in an accelerated fatigue tester. Front Med Biol Eng 2000; 10: 167-76.
-
(2000)
Front Med. Biol. Eng.
, vol.10
, pp. 167-176
-
-
Lee, H.S.1
Shimooka, T.2
Mitamura, Y.3
Yamamoto, K.4
Yuhta, T.5
-
12
-
-
0041828719
-
Measurement of the closing behavior of the Björk-Shiley monoleaflet mechanical heart valve with an electrohydraulic total artificial heart
-
Lee HS, Tsukiya T, Homma A, Taenaka Y, Tatsumi E, Takano H. Measurement of the closing behavior of the Björk-Shiley monoleaflet mechanical heart valve with an electrohydraulic total artificial heart. Artif Organs 2003; 27: 744-8.
-
(2003)
Artif. Organs
, vol.27
, pp. 744-748
-
-
Lee, H.S.1
Tsukiya, T.2
Homma, A.3
Taenaka, Y.4
Tatsumi, E.5
Takano, H.6
-
13
-
-
0038556975
-
The national cardiovascular center electrohydraulic total artificial heart and ventricular assist device systems: Current status of development
-
Tatsumi E, Taenaka Y, Homma A, et al. The national cardiovascular center electrohydraulic total artificial heart and ventricular assist device systems: Current status of development. ASAIO J 2003; 49: 243-9.
-
(2003)
ASAIO J.
, vol.49
, pp. 243-249
-
-
Tatsumi, E.1
Taenaka, Y.2
Homma, A.3
|