메뉴 건너뛰기




Volumn 398, Issue 1-3, 2005, Pages 25-36

Statistical estimation with Kronecker products in positron emission tomography

Author keywords

Kronecker product; Linear models; Partial volume correction; Positron emission tomography

Indexed keywords

ALGORITHMS; BRAIN; DATA REDUCTION; MATRIX ALGEBRA; MEDICAL IMAGING; NEUROLOGY; POSITRON EMISSION TOMOGRAPHY; STATISTICAL METHODS;

EID: 13544274103     PISSN: 00243795     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.laa.2003.11.018     Document Type: Article
Times cited : (3)

References (15)
  • 1
    • 0034241796 scopus 로고    scopus 로고
    • Inaugural article: Positron emission tomography provides molecular imaging of biological processes
    • Phelps M.E. Inaugural article: positron emission tomography provides molecular imaging of biological processes. Proc. Natl. Acad. Sci. USA. 97(16):2000;9226-9233
    • (2000) Proc. Natl. Acad. Sci. USA , vol.97 , Issue.16 , pp. 9226-9233
    • Phelps, M.E.1
  • 2
    • 0033369820 scopus 로고    scopus 로고
    • Present and future capabilities of molecular imaging techniques to understand brain function
    • Jones T. Present and future capabilities of molecular imaging techniques to understand brain function. J. Psychopharmacol. 13(4):1999;324-329
    • (1999) J. Psychopharmacol. , vol.13 , Issue.4 , pp. 324-329
    • Jones, T.1
  • 3
    • 0035106182 scopus 로고    scopus 로고
    • Introduction to pet instrumentation
    • Turkington T.G. Introduction to pet instrumentation. J. Nucl. Med. Technol. 29(1):2001;4-11
    • (2001) J. Nucl. Med. Technol. , vol.29 , Issue.1 , pp. 4-11
    • Turkington, T.G.1
  • 4
    • 0041726159 scopus 로고    scopus 로고
    • Statistical approaches in quantitative positron emission tomography
    • Leahy R.M., Qi J.Y. Statistical approaches in quantitative positron emission tomography. Statist. Comput. 10(2):2000;147-165
    • (2000) Statist. Comput. , vol.10 , Issue.2 , pp. 147-165
    • Leahy, R.M.1    Qi, J.Y.2
  • 6
    • 0018367149 scopus 로고
    • Quantitation in positron emission computed tomography: 1. Effect of object size
    • Hoffman E.J., Huang S.C., Phelps M.E. Quantitation in positron emission computed tomography: 1. Effect of object size. J. Comput. Assist. Tomogr. 3(3):1979;299-308
    • (1979) J. Comput. Assist. Tomogr. , vol.3 , Issue.3 , pp. 299-308
    • Hoffman, E.J.1    Huang, S.C.2    Phelps, M.E.3
  • 8
    • 0031028413 scopus 로고    scopus 로고
    • Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures
    • Studholme C., Hill D.L., Hawkes D.J. Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures. Med. Phys. 24(1):1997;25-35
    • (1997) Med. Phys. , vol.24 , Issue.1 , pp. 25-35
    • Studholme, C.1    Hill, D.L.2    Hawkes, D.J.3
  • 10
  • 11
    • 0043080074 scopus 로고    scopus 로고
    • Kronecker product and svd approximations in image restoration
    • Kamm J., Nagy J.G. Kronecker product and svd approximations in image restoration. Linear Algebra Appl. 284:1998;177-192
    • (1998) Linear Algebra Appl. , vol.284 , pp. 177-192
    • Kamm, J.1    Nagy, J.G.2
  • 13
    • 0036898673 scopus 로고    scopus 로고
    • Correction of partial-volume effect for pet striatal imaging: Fast implementation and study of robustness
    • Frouin V., Comtat C., Reilhac A., Greǵoire M.-C. Correction of partial-volume effect for pet striatal imaging: fast implementation and study of robustness. J. Nucl. Med. 43(12):2002;1715-1726
    • (2002) J. Nucl. Med. , vol.43 , Issue.12 , pp. 1715-1726
    • Frouin, V.1    Comtat, C.2    Reilhac, A.3    Greǵoire, M.-C.4
  • 14
    • 0029792211 scopus 로고    scopus 로고
    • Positron emission tomography metabolic data corrected for cortical atrophy using magnetic resonance imaging
    • Labbé C., Froment J.C., Kennedy A., Ashburner J., Cinotti L. Positron emission tomography metabolic data corrected for cortical atrophy using magnetic resonance imaging. Alzheimer Dis. Assoc. Disord. 10(3):1996;141-170
    • (1996) Alzheimer Dis. Assoc. Disord. , vol.10 , Issue.3 , pp. 141-170
    • Labbé, C.1    Froment, J.C.2    Kennedy, A.3    Ashburner, J.4    Cinotti, L.5
  • 15
    • 0031955835 scopus 로고    scopus 로고
    • Correction for partial volume effects in PET: Principle and validation
    • Rousset O.G., Ma Y., Evans A.C. Correction for partial volume effects in PET: principle and validation. J. Nucl. Med. 39(5):1998;904-911
    • (1998) J. Nucl. Med. , vol.39 , Issue.5 , pp. 904-911
    • Rousset, O.G.1    Ma, Y.2    Evans, A.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.