메뉴 건너뛰기




Volumn 13, Issue 2, 2005, Pages 583-594

High speed full range complex spectral domain optical coherence tomography

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; BIOLOGICAL ORGANS; COHERENT LIGHT; FOURIER TRANSFORMS; INTERFEROMETERS; MEDICAL IMAGING; OPHTHALMOLOGY; PHASE MODULATION; PHASE SHIFT; SPECTROMETERS;

EID: 13544261674     PISSN: 10944087     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OPEX.13.000583     Document Type: Article
Times cited : (124)

References (23)
  • 4
    • 0038618462 scopus 로고    scopus 로고
    • Performance of Fourier Domain vs. Time Domain optical coherence tomography
    • R. A. Leitgeb, C. K. Hitzenberger, and A. F. Fercher, "Performance of Fourier Domain vs. Time Domain optical coherence tomography," Opt. Express 11, 889-894 (2003), http://www.opticsexpress.org/abstract.cfm?URI=OPEX-11-8-889.
    • (2003) Opt. Express , vol.11 , pp. 889-894
    • Leitgeb, R.A.1    Hitzenberger, C.K.2    Fercher, A.F.3
  • 5
    • 0242301675 scopus 로고    scopus 로고
    • Improved signal to noise ratio in spectral domain compared with time domain optical coherence tomography
    • J. F. de Boer, B. Cense, B. H. Park, M. C. Pierce, G. J. Tearney, and B. E. Bouma, "Improved signal to noise ratio in spectral domain compared with time domain optical coherence tomography," Opt. Lett. 28, 2067-2069 (2003).
    • (2003) Opt. Lett. , vol.28 , pp. 2067-2069
    • De Boer, J.F.1    Cense, B.2    Park, B.H.3    Pierce, M.C.4    Tearney, G.J.5    Bouma, B.E.6
  • 6
    • 2942703878 scopus 로고    scopus 로고
    • Sensitivity advantage of swept source and Fourier domain optical coherence tomography
    • M. A. Choma, M. V. Sarunic, C. Yang, and J. A. Izatt, "Sensitivity advantage of swept source and Fourier domain optical coherence tomography, " Opt. Express 11, 2183-2189 (2003), http://www.opticsexpress.org/abstract.cfm?URI=OPEX-11-18-2183.
    • (2003) Opt. Express , vol.11 , pp. 2183-2189
    • Choma, M.A.1    Sarunic, M.V.2    Yang, C.3    Izatt, J.A.4
  • 8
    • 0001936881 scopus 로고
    • Measurement of intraocular distances by backscattering spectral interferometry
    • A. F. Fercher, C. K. Hitzenberger, G. Kamp, and S. Y. El- Zaiat, "Measurement of intraocular distances by backscattering spectral interferometry," Opt. Commun. 117, 43-48 (1995).
    • (1995) Opt. Commun. , vol.117 , pp. 43-48
    • Fercher, A.F.1    Hitzenberger, C.K.2    Kamp, G.3    El-Zaiat, S.Y.4
  • 9
    • 0031695986 scopus 로고    scopus 로고
    • Coherence radar and spectral radar - New tools for dermatological diagnosis
    • G. Häusler and M. W. Lindner, "Coherence radar and spectral radar - new tools for dermatological diagnosis," J. Biomed. Opt. 3, 21-31 (1998).
    • (1998) J. Biomed. Opt. , vol.3 , pp. 21-31
    • Häusler, G.1    Lindner, M.W.2
  • 12
    • 0037103599 scopus 로고    scopus 로고
    • Full range complex spectral optical coherence tomography technique in eye imaging
    • M. Wojtkowski, A. Kowalczyk, R. Leitgeb, and A. F. Fercher, "Full range complex spectral optical coherence tomography technique in eye imaging," Opt. Lett. 27, 1415-1417 (2002).
    • (2002) Opt. Lett. , vol.27 , pp. 1415-1417
    • Wojtkowski, M.1    Kowalczyk, A.2    Leitgeb, R.3    Fercher, A.F.4
  • 14
    • 0242662006 scopus 로고    scopus 로고
    • Phase shifting algorithm to achieve high speed long depth range probing by frequency domain optical coherence tomography
    • R. A. Leitgeb, C. K. Hitzenberger, A. F. Fercher, and T. Bajraszewski, "Phase shifting algorithm to achieve high speed long depth range probing by frequency domain optical coherence tomography," Opt. Lett. 28, 2201-2003 (2003).
    • (2003) Opt. Lett. , vol.28 , pp. 2201-12003
    • Leitgeb, R.A.1    Hitzenberger, C.K.2    Fercher, A.F.3    Bajraszewski, T.4
  • 16
    • 2942720818 scopus 로고    scopus 로고
    • In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve
    • N. A. Nassif, B. Cense, B. H. Park, M. C. Pierce, S. H. Yun, B. E. Bouma, G. J. Tearney, T. C. Chen, and J. F. de Boer, "In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve," Opt. Express 12, 367-376 (2004), http://www.opticsexpress.org/abstract.cfm?URI=OPEX-12-3-367.
    • (2004) Opt. Express , vol.12 , pp. 367-376
    • Nassif, N.A.1    Cense, B.2    Park, B.H.3    Pierce, M.C.4    Yun, S.H.5    Bouma, B.E.6    Tearney, G.J.7    Chen, T.C.8    De Boer, J.F.9
  • 18
    • 2942701942 scopus 로고    scopus 로고
    • Ultrahigh-resolution high speed retinal imaging using spectral-domain optical coherence tomography
    • B. Cense, N. A. Nassif, T. C. Chen, M. C. Pierce, S. H. Yun, B. H. Park, B. E. Bouma, G. J. Tearney, and J. F. de Boer, "Ultrahigh-resolution high speed retinal imaging using spectral-domain optical coherence tomography," Opt. Express 12, 2435-2447 (2004), http://www.opticsexpress.org/abstract.cfm?URI=OPEX-12-11-2435.
    • (2004) Opt. Express , vol.12 , pp. 2435-2447
    • Cense, B.1    Nassif, N.A.2    Chen, T.C.3    Pierce, M.C.4    Yun, S.H.5    Park, B.H.6    Bouma, B.E.7    Tearney, G.J.8    De Boer, J.F.9
  • 19
    • 2942726216 scopus 로고    scopus 로고
    • Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation
    • M. Wojtkowski, V. J. Srinivasan, T. H. Ko, J. G. Fujimoto, A. Kowalczyk, and J. S. Duker, "Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation," Opt. Express 12, 2404-2422 (2004), http://www.opticsexpress.org/abstract.cfm?URI=OPEX-12-11-2404.
    • (2004) Opt. Express , vol.12 , pp. 2404-2422
    • Wojtkowski, M.1    Srinivasan, V.J.2    Ko, T.H.3    Fujimoto, J.G.4    Kowalczyk, A.5    Duker, J.S.6
  • 20
    • 0001203103 scopus 로고    scopus 로고
    • Coherence imaging by use of a Newton rings sampling function
    • A. G. Podoleanu, G. M. Dobre, D. J. Webb, and D. A. Jackson, "Coherence imaging by use of a Newton rings sampling function," Opt. Lett. 21, 1789-1791 (1996).
    • (1996) Opt. Lett. , vol.21 , pp. 1789-1791
    • Podoleanu, A.G.1    Dobre, G.M.2    Webb, D.J.3    Jackson, D.A.4
  • 21
    • 0001673882 scopus 로고    scopus 로고
    • En face coherence imaging using galvanometer scanner modulation
    • A. G. Podoleanu, G. M. Dobre, and D. A. Jackson, "En face coherence imaging using galvanometer scanner modulation," Opt. Lett. 23, 147-149 (1998).
    • (1998) Opt. Lett. , vol.23 , pp. 147-149
    • Podoleanu, A.G.1    Dobre, G.M.2    Jackson, D.A.3
  • 22
    • 4644298765 scopus 로고    scopus 로고
    • Motion artifacts in optical coherence tomography with frequency domain ranging
    • S. H. Yun, G. J. Tearney, J. F. de Boer, and B. E. Bouma, "Motion artifacts in optical coherence tomography with frequency domain ranging," Opt Express 12, 2977-2998 (2004), http://www.opticsexpress.org/abstract.cfm?URI=OPEX-12-13-2977.
    • (2004) Opt Express , vol.12 , pp. 2977-2998
    • Yun, S.H.1    Tearney, G.J.2    De Boer, J.F.3    Bouma, B.E.4
  • 23
    • 0003492957 scopus 로고    scopus 로고
    • ANSI Z136.1-2000. Orlando, Laser Institute of America
    • American National Standards Institute: "American National Standard for Safe Use of Lasers," ANSI Z136.1-2000. Orlando, Laser Institute of America, 35-49 (2000).
    • (2000) American National Standard for Safe Use of Lasers , pp. 35-49


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.