메뉴 건너뛰기




Volumn 60, Issue 2, 2005, Pages 184-188

Comparison of fibreoptic-guided orotracheal intubation through classic and single-use laryngeal mask airways

Author keywords

[No Author keywords available]

Indexed keywords

FENTANYL; ISOFLURANE; MIDAZOLAM; OXYGEN; PROPOFOL; VECURONIUM;

EID: 13544254550     PISSN: 00032409     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1365-2044.2004.04045.x     Document Type: Article
Times cited : (41)

References (19)
  • 1
    • 0036174227 scopus 로고    scopus 로고
    • Comparison of times to achieve tracheal intubation using the laryngeal or intubating laryngeal mask airway
    • Pandit JJ, MacLachlan K, Dravid RM, Popat MT. Comparison of times to achieve tracheal intubation using the laryngeal or intubating laryngeal mask airway. Anaesthesia 2002; 57: 128-32.
    • (2002) Anaesthesia , vol.57 , pp. 128-132
    • Pandit, J.J.1    MacLachlan, K.2    Dravid, R.M.3    Popat, M.T.4
  • 2
    • 3242884152 scopus 로고    scopus 로고
    • Difficult Airway Society guidelines for management of the unanticipated difficult intubation
    • Henderson JJ, Popat MT, Latto IP, Pearce AC. Difficult Airway Society guidelines for management of the unanticipated difficult intubation. Anaesthesia 2004; 59: 675-94.
    • (2004) Anaesthesia , vol.59 , pp. 675-694
    • Henderson, J.J.1    Popat, M.T.2    Latto, I.P.3    Pearce, A.C.4
  • 3
    • 0037406762 scopus 로고    scopus 로고
    • Practice guidelines for management of the difficult airway. An updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway
    • Anonymous
    • Anonymous. Practice guidelines for management of the difficult airway. An updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology 2003; 98: 1269-77.
    • (2003) Anesthesiology , vol.98 , pp. 1269-1277
  • 4
    • 0034762389 scopus 로고    scopus 로고
    • Presence of protein deposits on 'cleaned' re-usable anaesthetic equipment
    • Miller DM, Youkhama I, Karunaratne WU, Pearce A. Presence of protein deposits on 'cleaned' re-usable anaesthetic equipment. Anaesthesia 2001; 56: 1069-72.
    • (2001) Anaesthesia , vol.56 , pp. 1069-1072
    • Miller, D.M.1    Youkhama, I.2    Karunaratne, W.U.3    Pearce, A.4
  • 5
    • 0141681086 scopus 로고    scopus 로고
    • Routine cleaning and autoclaving does not remove protein deposits from reusable laryngeal mask devices
    • Clery G, Brimacombe J, Stone T, Keller C, Curtis S. Routine cleaning and autoclaving does not remove protein deposits from reusable laryngeal mask devices. Anesthesia and Analgesia 2003; 97: 1189-91.
    • (2003) Anesthesia and Analgesia , vol.97 , pp. 1189-1191
    • Clery, G.1    Brimacombe, J.2    Stone, T.3    Keller, C.4    Curtis, S.5
  • 6
    • 0242269043 scopus 로고    scopus 로고
    • Comparison of the LMA-classic with the new disposable soft laryngeal mask in spontaneously breathing adult patients
    • Van Zundert AA, Fonck K, Al-Shaikh B, Mortier E. Comparison of the LMA-classic with the new disposable soft laryngeal mask in spontaneously breathing adult patients. Anesthesiology 2003; 99 1066-71.
    • (2003) Anesthesiology , vol.99 , pp. 1066-1071
    • Van Zundert, A.A.1    Fonck, K.2    Al-Shaikh, B.3    Mortier, E.4
  • 8
    • 0023238545 scopus 로고
    • Difficult tracheal intubation: A retrospective study
    • Samsoon GLT, Young JRB. Difficult tracheal intubation: a retrospective study. Anaesthesia 1987; 42: 487-90.
    • (1987) Anaesthesia , vol.42 , pp. 487-490
    • Samsoon, G.L.T.1    Young, J.R.B.2
  • 9
    • 0020562072 scopus 로고
    • Predicting the difficulty of tracheal intubation utilizing an intubation guide
    • Patil UV, Stehling LC, Zauder HL. Predicting the difficulty of tracheal intubation utilizing an intubation guide. Anesthesiology Review 1983; 10: 32-3.
    • (1983) Anesthesiology Review , vol.10 , pp. 32-33
    • Patil, U.V.1    Stehling, L.C.2    Zauder, H.L.3
  • 10
    • 0026350145 scopus 로고
    • Management of the difficult airway with special emphasis on awake tracheal intubation
    • Benumof JL. Management of the difficult airway with special emphasis on awake tracheal intubation. Anesthesiology 1991; 75 1087-110.
    • (1991) Anesthesiology , vol.75 , pp. 1087-1110
    • Benumof, J.L.1
  • 12
    • 0021701206 scopus 로고
    • Difficult tracheal intubation in obstetrics
    • Cormack RS, Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia 1984; 39: 1105-11.
    • (1984) Anaesthesia , vol.39 , pp. 1105-1111
    • Cormack, R.S.1    Lehane, J.2
  • 13
    • 0027528467 scopus 로고
    • A proposed fibre-optic scoring system to standardise the assessment of laryngeal mask airway position
    • Brimacombe J, Berry A. A proposed fibre-optic scoring system to standardise the assessment of laryngeal mask airway position. Anesthesia and Analgesia 1993; 76: 457.
    • (1993) Anesthesia and Analgesia , vol.76 , pp. 457
    • Brimacombe, J.1    Berry, A.2
  • 14
    • 0026653725 scopus 로고
    • Sixteen s squared over d squared: A relation for crude sample size estimates
    • Lehr S. Sixteen s squared over d squared: a relation for crude sample size estimates. Statistics in Medicine 1992; 11: 1099-102.
    • (1992) Statistics in Medicine , vol.11 , pp. 1099-1102
    • Lehr, S.1
  • 15
    • 0034104349 scopus 로고    scopus 로고
    • A new practical classification of laryngeal view
    • Cook TM. A new practical classification of laryngeal view. Anaesthesia 2000; 55: 274-9.
    • (2000) Anaesthesia , vol.55 , pp. 274-279
    • Cook, T.M.1
  • 16
    • 0034939042 scopus 로고    scopus 로고
    • A manoeuvre for using the flexible fibreoptic bronchoscope through the intubating laryngeal mask airway
    • Panjwani S, Seymour P, Pandit JJ. A manoeuvre for using the flexible fibreoptic bronchoscope through the intubating laryngeal mask airway. Anaesthesia 2001; 56: 696-7.
    • (2001) Anaesthesia , vol.56 , pp. 696-697
    • Panjwani, S.1    Seymour, P.2    Pandit, J.J.3
  • 17
    • 85046173570 scopus 로고    scopus 로고
    • Usable versus overall tracheal tube length: The difference may be critical
    • Harvey SC, Bailey MK, Cooke JE. Usable versus overall tracheal tube length: the difference may be critical. Anesthesiology 1997; 87: 173.
    • (1997) Anesthesiology , vol.87 , pp. 173
    • Harvey, S.C.1    Bailey, M.K.2    Cooke, J.E.3
  • 18
    • 0027202276 scopus 로고
    • The distance between the grille of the laryngeal mask airway and the vocal cords. Is conventional intubation through the laryngeal mask safe?
    • Asai T, Latto P, Vaughan RS. The distance between the grille of the laryngeal mask airway and the vocal cords. Is conventional intubation through the laryngeal mask safe? Anaesthesia 1993; 48 667-9.
    • (1993) Anaesthesia , vol.48 , pp. 667-669
    • Asai, T.1    Latto, P.2    Vaughan, R.S.3
  • 19
    • 0031794505 scopus 로고    scopus 로고
    • A prospective evaluation of clinical tests for placement of laryngeal mask airways
    • Joshi S, Sciacca RR, Solanki DR, Young WL, Mathru MM. A prospective evaluation of clinical tests for placement of laryngeal mask airways. Anesthesiology 1998; 89: 1141-6.
    • (1998) Anesthesiology , vol.89 , pp. 1141-1146
    • Joshi, S.1    Sciacca, R.R.2    Solanki, D.R.3    Young, W.L.4    Mathru, M.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.