Volumn 20, Issue 4, 2004, Pages 503-507

Hologamous integrating strategies for incipient fault diagnosis of transformer

Author keywords

Fault diagnosis; Hologamous system; Integrating; Power transformer

Indexed keywords

DATABASE SYSTEMS; EXPERT SYSTEMS; FOURIER TRANSFORMS; FUZZY CONTROL; MONITORING; NEURAL NETWORKS; PROGRAM DIAGNOSTICS;

EID: 13444311701     PISSN: 10037985     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (8)
  • 1
    • 0029407969 scopus 로고
    • Proposals for an improvement in transformers diagnosis using dissolved gas analysis (DGA)
    • Kan Hisao, Miyamoto Teruo. Proposals for an improvement in transformers diagnosis using dissolved gas analysis (DGA)[J]. IEEE Trans on Electrical Insulation Magazine, 1995, 11(6): 15-21.
    • (1995) IEEE Trans on Electrical Insulation Magazine , vol.11 , Issue.6 , pp. 15-21
    • Hisao, K.1    Teruo, M.2
  • 2
    • 0032627149 scopus 로고    scopus 로고
    • On-line partial discharge calibration and monitoring for power transformers
    • Farag A S, Shewhdi M H, Jin X, et al. On-line partial discharge calibration and monitoring for power transformers[J]. Electric Power Systems Research, 1999, 50(1): 47-54.
    • (1999) Electric Power Systems Research , vol.50 , Issue.1 , pp. 47-54
    • Farag, A.S.1    Shewhdi, M.H.2    Jin, X.3
  • 3
    • 13444265338 scopus 로고    scopus 로고
    • A database-based diagnostic expert system of transformer's faults
    • Chinese source
    • Zhou Jianhua, Hu Minqiang. A database-based diagnostic expert system of transformer's faults[J]. Journal of Southeast University (Natural Science Edition), 1998, 28(6): 68-73. (in Chinese)
    • (1998) Journal of Southeast University (Natural Science Edition) , vol.28 , Issue.6 , pp. 68-73
    • Zhou, J.1    Hu, M.2
  • 5
    • 2542455882 scopus 로고    scopus 로고
    • On the application of CP-BP algorithm for DGA-NN diagnosis in power transformer
    • Chinese source
    • Zhou Jianhua, Hu Minqiang, Zhou E. On the application of CP-BP algorithm for DGA-NN diagnosis in power transformer[J]. Proceedings of the CSEE, 1999, 19(3): 41-45. (in Chinese)
    • (1999) Proceedings of the CSEE , vol.19 , Issue.3 , pp. 41-45
    • Zhou, J.1    Hu, M.2    Zhou, E.3
  • 6
    • 0035392173 scopus 로고    scopus 로고
    • Condition monitoring of power transformer on-load tap-changers, Part 1: Automatic condition diagnostics
    • Kang P, Birtwhistle D. Condition monitoring of power transformer on-load tap-changers, part 1: automatic condition diagnostics[J]. IEE Proceedings of Generation, Transmission and Distribution, 2001, 148(4): 301-306.
    • (2001) IEE Proceedings of Generation, Transmission and Distribution , vol.148 , Issue.4 , pp. 301-306
    • Kang, P.1    Birtwhistle, D.2
  • 7
    • 0141527662 scopus 로고    scopus 로고
    • Integrating ES with ANN in fault diagnosis based on thinking-pattern
    • Chinese source
    • Zhou Jianhua, Hu Minqiang, Zhou E. Integrating ES with ANN in fault diagnosis based on thinking-pattern[J]. Transactions of China Electrotechnical Society, 1999, 12(2): 1-4. (in Chinese)
    • (1999) Transactions of China Electrotechnical Society , vol.12 , Issue.2 , pp. 1-4
    • Zhou, J.1    Hu, M.2    Zhou, E.3
  • 8
    • 4444357679 scopus 로고    scopus 로고
    • A study on synthetic diagnosis method for insulation of power transformers
    • Chinese source
    • Qian Zheng, Yan Zhang, Luo Chengmu. A study on synthetic diagnosis method for insulation of power transformers[J]. Power System Technology, 2002, 26(2): 32-36. (in Chinese)
    • (2002) Power System Technology , vol.26 , Issue.2 , pp. 32-36
    • Qian, Z.1    Yan, Z.2    Luo, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.