메뉴 건너뛰기




Volumn 22, Issue 2, 2005, Pages 111-119

Freehand three-dimensional echocardiography with rotational scanning for measurements of left ventricular volume and ejection fraction in patients with coronary artery disease

Author keywords

Coronary artery disease; Ejection fraction; Three dimensional echocardiography

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CORONARY ARTERY DISEASE; CORRELATION ANALYSIS; DIAGNOSTIC ACCURACY; FEASIBILITY STUDY; FEMALE; GEOMETRY; HEART LEFT VENTRICLE CONTRACTION; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE VOLUME; HEART VENTRICLE ENDDIASTOLIC PRESSURE; HUMAN; IMAGE ANALYSIS; MALE; OBSERVER VARIATION; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; ROTATION; SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY; THREE DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 13444280031     PISSN: 07422822     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.0742-2822.2005.03168.x     Document Type: Article
Times cited : (11)

References (24)
  • 1
    • 0031454710 scopus 로고    scopus 로고
    • Tomographic three-dimensional echocardiographic determination of chamber size and systolic function in patients with left ventricular aneurysm: Comparison to magnetic resonance imaging, cineventriculography, and two-dimensional echocardiography
    • Buck T, Hunold P, Wentz KU, et al: Tomographic three-dimensional echocardiographic determination of chamber size and systolic function in patients with left ventricular aneurysm: Comparison to magnetic resonance imaging, cineventriculography, and two-dimensional echocardiography. Circulation 1997;96:4286-4297.
    • (1997) Circulation , vol.96 , pp. 4286-4297
    • Buck, T.1    Hunold, P.2    Wentz, K.U.3
  • 2
    • 0029812979 scopus 로고    scopus 로고
    • Accurate measurement of left ventricular ejection fraction by three-dimensional echocardiography. A comparison with radionuclide angiography
    • Nosir YF, Fioretti PM, Vletter WB, et al: Accurate measurement of left ventricular ejection fraction by three- dimensional echocardiography. A comparison with radionuclide angiography. Circulation 1996;94:460-466.
    • (1996) Circulation , vol.94 , pp. 460-466
    • Nosir, Y.F.1    Fioretti, P.M.2    Vletter, W.B.3
  • 3
    • 0029117112 scopus 로고
    • Assessment of cardiac function by three-dimensional echocardiography compared with conventional noninvasive methods
    • Gopal AS, Shen Z, Sapin PM, et al: Assessment of cardiac function by three-dimensional echocardiography compared with conventional noninvasive methods. Circulation 1995;92:842-853.
    • (1995) Circulation , vol.92 , pp. 842-853
    • Gopal, A.S.1    Shen, Z.2    Sapin, P.M.3
  • 4
    • 0028094704 scopus 로고
    • Comparison of two- and three-dimensional echocardiography with cineventriculography for measurement of left ventricular volume in patients
    • Sapin PM, Schroder KM, Gopal AS, et al: Comparison of two- and three-dimensional echocardiography with cineventriculography for measurement of left ventricular volume in patients. J Am Coll Cardiol 1994;24:1054-1063.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 1054-1063
    • Sapin, P.M.1    Schroder, K.M.2    Gopal, A.S.3
  • 5
    • 0027367635 scopus 로고
    • Three-dimensional echocardiographic measurement of left ventricular volume in vitro: Comparison with two-dimensional echocardiography and cineventriculography
    • Sapin PM, Schroeder KD, Smith MD, et al: Three-dimensional echocardiographic measurement of left ventricular volume in vitro: Comparison with two-dimensional echocardiography and cineventriculography. J Am Coll Cardiol 1993;22:1530-1537.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1530-1537
    • Sapin, P.M.1    Schroeder, K.D.2    Smith, M.D.3
  • 6
    • 0030292333 scopus 로고    scopus 로고
    • Three-dimensional echocardiographic measurement of left ventricular volumes and ejection fraction using a multiplane transesophageal probe in patients
    • Hozumi T, Yoshikawa J, Yoshida K, et al: Three-dimensional echocardiographic measurement of left ventricular volumes and ejection fraction using a multiplane transesophageal probe in patients. Am J Cardiol 1996;78:1077-1080.
    • (1996) Am J Cardiol , vol.78 , pp. 1077-1080
    • Hozumi, T.1    Yoshikawa, J.2    Yoshida, K.3
  • 7
    • 0028541228 scopus 로고
    • A new method for echocardiographic computerized three-dimensional reconstruction of left ventricular endocardial surface: In vitro accuracy and clinical repeatability of volumes
    • Aakhus S, Maehle J, Bjoernstad K: A new method for echocardiographic computerized three-dimensional reconstruction of left ventricular endocardial surface: In vitro accuracy and clinical repeatability of volumes. J Am Soc Echocardiogr 1994;7:571-581.
    • (1994) J Am Soc Echocardiogr , vol.7 , pp. 571-581
    • Aakhus, S.1    Maehle, J.2    Bjoernstad, K.3
  • 8
    • 0031665957 scopus 로고    scopus 로고
    • Three-dimensional echocardiography: Precision and accuracy of left ventricular volume measurement using rotational geometry with variable numbers of slice resolution
    • Tanabe K, Belohlavek M, Jakrapanichakul D, et al: Three-dimensional echocardiography: Precision and accuracy of left ventricular volume measurement using rotational geometry with variable numbers of slice resolution. Echocardiography 1998;15:575-580.
    • (1998) Echocardiography , vol.15 , pp. 575-580
    • Tanabe, K.1    Belohlavek, M.2    Jakrapanichakul, D.3
  • 9
    • 0034811509 scopus 로고    scopus 로고
    • Three-dimensional transesophageal echocardiographic measurement of left ventricular volumes using the average rotation method: Comparison with the disk summation method
    • Kawai J, Yoshida K, Hozumi T, et al: Three-dimensional transesophageal echocardiographic measurement of left ventricular volumes using the average rotation method: Comparison with the disk summation method. J Cardiol 2001;38:153-161.
    • (2001) J Cardiol , vol.38 , pp. 153-161
    • Kawai, J.1    Yoshida, K.2    Hozumi, T.3
  • 10
    • 0037134836 scopus 로고    scopus 로고
    • Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: A meta-analysis
    • Ioannidis JP, Trikalinos TA, Danias PG: Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: A meta-analysis. J Am Coll Cardiol 2002;39:2059-2068.
    • (2002) J Am Coll Cardiol , vol.39 , pp. 2059-2068
    • Ioannidis, J.P.1    Trikalinos, T.A.2    Danias, P.G.3
  • 11
    • 18044368618 scopus 로고    scopus 로고
    • Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: Comparison of two methods
    • Faber TL, Vansant JP, Pettigrew RI, et al: Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: Comparison of two methods. J Nucl Cardiol 2001;8:645-651.
    • (2001) J Nucl Cardiol , vol.8 , pp. 645-651
    • Faber, T.L.1    Vansant, J.P.2    Pettigrew, R.I.3
  • 12
    • 0028807605 scopus 로고
    • Automatic quantification of ejection fraction from gated myocardial perfusion SPECT
    • Germano G, Kiat H, Kavanagh PB, et al: Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995;36:2138-2147.
    • (1995) J Nucl Med , vol.36 , pp. 2138-2147
    • Germano, G.1    Kiat, H.2    Kavanagh, P.B.3
  • 13
    • 0030810148 scopus 로고    scopus 로고
    • Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography
    • Germano G, Erel J, Lewin H, et al: Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 1997;30:1360-1367.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1360-1367
    • Germano, G.1    Erel, J.2    Lewin, H.3
  • 14
    • 0024723470 scopus 로고
    • Recommendations for quantitation of the left ventricle by two-dimensional echocardiography
    • American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms
    • Schiller NB, Shah PM, Crawford M, et al: Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr 1989;2:358-367.
    • (1989) J Am Soc Echocardiogr , vol.2 , pp. 358-367
    • Schiller, N.B.1    Shah, P.M.2    Crawford, M.3
  • 15
    • 0036169405 scopus 로고    scopus 로고
    • Incremental value of left ventricular ejection fraction for detection of multivessel coronary artery disease in exercise (201)Tl gated myocardial perfusion imaging
    • Yamagishi H, Shirai N, Yoshiyama M, et al: Incremental value of left ventricular ejection fraction for detection of multivessel coronary artery disease in exercise (201)Tl gated myocardial perfusion imaging. J Nucl Med 2002;43:131-139.
    • (2002) J Nucl Med , vol.43 , pp. 131-139
    • Yamagishi, H.1    Shirai, N.2    Yoshiyama, M.3
  • 16
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altaian DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altaian, D.G.2
  • 17
    • 0020666789 scopus 로고
    • Echoventriculography - A simultaneous analysis of two-dimensional echocardiography and cineventriculography
    • Erbel R, Schweizer P, Lambertz H, et al: Echoventriculography - a simultaneous analysis of two-dimensional echocardiography and cineventriculography. Circulation 1983;67:205-215.
    • (1983) Circulation , vol.67 , pp. 205-215
    • Erbel, R.1    Schweizer, P.2    Lambertz, H.3
  • 18
    • 0019498258 scopus 로고
    • Reproducibility of left ventricular internal dimensions with M mode echocardiography: Effects of heart size, body position and transducer angulation
    • Wong M, Shah PM, Taylor RD. Reproducibility of left ventricular internal dimensions with M mode echocardiography: Effects of heart size, body position and transducer angulation. Am J Cardiol 1981;47:1068-1074.
    • (1981) Am J Cardiol , vol.47 , pp. 1068-1074
    • Wong, M.1    Shah, P.M.2    Taylor, R.D.3
  • 19
    • 0017279676 scopus 로고
    • Problems in echocardiographic volume determinations: Echocardiographic- angiographic correlations in the presence of absence of asynergy
    • Teichholz LE, Kreulen T, Herman MV, et al: Problems in echocardiographic volume determinations: Echocardiographic-angiographic correlations in the presence of absence of asynergy. Am J Cardiol 1976;37:7-11.
    • (1976) Am J Cardiol , vol.37 , pp. 7-11
    • Teichholz, L.E.1    Kreulen, T.2    Herman, M.V.3
  • 20
    • 0029362281 scopus 로고
    • Three-dimensional echocardiography: Limitations of apical biplane imaging for measurement of left ventricular volume
    • Sapin PM, Schroeder KM, Gopal AS, et al: Three-dimensional echocardiography: Limitations of apical biplane imaging for measurement of left ventricular volume. J Am Soc Echocardiogr 1995;8:576-584.
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 576-584
    • Sapin, P.M.1    Schroeder, K.M.2    Gopal, A.S.3
  • 21
    • 0030090116 scopus 로고    scopus 로고
    • Three-dimensional echocardiography: The influence of number of component images on accuracy of left ventricular volume quantitation
    • Siu SC, Rivera JM, Handschumacher MD, et al: Three-dimensional echocardiography: The influence of number of component images on accuracy of left ventricular volume quantitation. J Am Soc Echocardiogr 1996;9:147-155.
    • (1996) J Am Soc Echocardiogr , vol.9 , pp. 147-155
    • Siu, S.C.1    Rivera, J.M.2    Handschumacher, M.D.3
  • 22
    • 0032374077 scopus 로고    scopus 로고
    • Relation between the number of image planes and the accuracy of three-dimensional echocardiography for measuring left ventricular volumes and ejection fraction
    • Danias PG, Chuang ML, Parker RA, et al: Relation between the number of image planes and the accuracy of three-dimensional echocardiography for measuring left ventricular volumes and ejection fraction. Am J Cardiol 1998;82:1431-1434, A9.
    • (1998) Am J Cardiol , vol.82 , pp. 1431-1434
    • Danias, P.G.1    Chuang, M.L.2    Parker, R.A.3
  • 23
    • 0345701206 scopus 로고    scopus 로고
    • Rapid freehand scanning three-dimensional echocardiography: Accurate measurement of left ventricular volumes and ejection fraction compared with quantitative gated scintigraphy
    • Kawai J, Tanabe K, Morioka S, et al: Rapid freehand scanning three-dimensional echocardiography: Accurate measurement of left ventricular volumes and ejection fraction compared with quantitative gated scintigraphy. J Am Soc Echocardiogr 2003;16:110-115.
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 110-115
    • Kawai, J.1    Tanabe, K.2    Morioka, S.3
  • 24
    • 10744230374 scopus 로고    scopus 로고
    • Rapid and accurate noninvasive assessment of global left ventricular systolic function using biplane advanced automated contour tracking method
    • Sugioka K, Hozumi T, Watanabe H, et al: Rapid and accurate noninvasive assessment of global left ventricular systolic function using biplane advanced automated contour tracking method. J Am Soc Echocardiogr 2003;16:1237-1243.
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 1237-1243
    • Sugioka, K.1    Hozumi, T.2    Watanabe, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.