메뉴 건너뛰기




Volumn 25, Issue 1, 2005, Pages 26-29

Agreement of carbon dioxide levels measured by arterial, transcutaneous and end tidal methods in preterm infants ≤ 28 weeks gestation

Author keywords

[No Author keywords available]

Indexed keywords

ARTERIAL CARBON DIOXIDE TENSION; ARTICLE; ARTIFICIAL VENTILATION; CLINICAL ARTICLE; CORRELATION COEFFICIENT; END TIDAL CARBON DIOXIDE TENSION; FEMALE; HUMAN; INTERMETHOD COMPARISON; MALE; NEONATAL RESPIRATORY DISTRESS SYNDROME; NEWBORN; NON INVASIVE MEASUREMENT; PREMATURITY; TRANSCUTANEOUS CARBON DIOXIDE MONITORING;

EID: 13444271044     PISSN: 07438346     EISSN: None     Source Type: Journal    
DOI: 10.1038/sj.jp.7211202     Document Type: Article
Times cited : (50)

References (18)
  • 1
    • 0024405425 scopus 로고
    • Discrepancies between transcutaneous and end tidal carbon dioxide monitoring in critically ill neonate with respiratory distress syndrome
    • Hand IL, Shepard E, Krauss AN, Auld PA. Discrepancies between transcutaneous and end tidal carbon dioxide monitoring in critically ill neonate with respiratory distress syndrome. Crit Care Med 1989;17:556-9.
    • (1989) Crit. Care Med. , vol.17 , pp. 556-559
    • Hand, I.L.1    Shepard, E.2    Krauss, A.N.3    Auld, P.A.4
  • 2
    • 0023087357 scopus 로고
    • Combined transcutaneous oxygen, carbon dioxide tensions and end-expired CO2 levels in severely ill newborns
    • Geven WB, Nagler E, de Boo T, Lemmens W. Combined transcutaneous oxygen, carbon dioxide tensions and end-expired CO2 levels in severely ill newborns. Adv Exp Med Biol 1987;220:115-20.
    • (1987) Adv. Exp. Med. Biol. , vol.220 , pp. 115-120
    • Geven, W.B.1    Nagler, E.2    de Boo, T.3    Lemmens, W.4
  • 3
    • 0023239492 scopus 로고
    • Monitoring of end tidal CO2 in neonatal intensive care
    • Watkins AM, Weindling AM. Monitoring of end tidal CO2 in neonatal intensive care. Arch Dis Child 1987;62:837-9.
    • (1987) Arch. Dis. Child , vol.62 , pp. 837-839
    • Watkins, A.M.1    Weindling, A.M.2
  • 4
    • 0037384489 scopus 로고    scopus 로고
    • Good estimation of arterial carbon dioxide by end tidal carbon dioxide monitoring in the neonatal intensive care unit
    • Wu CH, Chou HC, Hsieh WS, Chen WK, Huang PY, Tsao PN. Good estimation of arterial carbon dioxide by end tidal carbon dioxide monitoring in the neonatal intensive care unit. Pediatric Pulmonol 2003;35:292-5.
    • (2003) Pediatric Pulmonol. , vol.35 , pp. 292-295
    • Wu, C.H.1    Chou, H.C.2    Hsieh, W.S.3    Chen, W.K.4    Huang, P.Y.5    Tsao, P.N.6
  • 5
    • 0031128863 scopus 로고    scopus 로고
    • End tidal carbon dioxide monitoring - Its reliability in neonates
    • Nangia S, Saili A, Dutta AK. End tidal carbon dioxide monitoring - its reliability in neonates. Indian J Pediatr 1997;64:389-94.
    • (1997) Indian J. Pediatr. , vol.64 , pp. 389-394
    • Nangia, S.1    Saili, A.2    Dutta, A.K.3
  • 6
    • 0342547313 scopus 로고    scopus 로고
    • Noninvasive monitoring of carbon dioxide during respiratory failure in toddlers and infants: End-tidal versus transcutaneous carbon dioxide
    • Tobias JD, Meyer DJ. Noninvasive monitoring of carbon dioxide during respiratory failure in toddlers and infants: end-tidal versus transcutaneous carbon dioxide. Anesth Analg 1997;85:55-8.
    • (1997) Anesth. Analg. , vol.85 , pp. 55-58
    • Tobias, J.D.1    Meyer, D.J.2
  • 7
    • 0023607877 scopus 로고
    • Comparison of noninvasive measurements of carbon dioxide tensions during withdrawal from mechanical ventilation
    • Healey CJ, Fedullo AJ, Swinburne AJ, Wahl GA. Comparison of noninvasive measurements of carbon dioxide tensions during withdrawal from mechanical ventilation. Crit Care Med 1987;15(8):764-8.
    • (1987) Crit. Care Med. , vol.15 , Issue.8 , pp. 764-768
    • Healey, C.J.1    Fedullo, A.J.2    Swinburne, A.J.3    Wahl, G.A.4
  • 8
    • 0026517541 scopus 로고
    • Comparison of transcutaneous end tidal and arterial measurements of carbon dioxide during general anesthesia
    • Reid CW, Martineua RJ, Miller DR, Hull KA, Baines J, Sullivan PJ. Comparison of transcutaneous end tidal and arterial measurements of carbon dioxide during general anesthesia. Can J Anesth 1992;39:31-6.
    • (1992) Can. J. Anesth. , vol.39 , pp. 31-36
    • Reid, C.W.1    Martineua, R.J.2    Miller, D.R.3    Hull, K.A.4    Baines, J.5    Sullivan, P.J.6
  • 9
    • 0023485723 scopus 로고
    • 2 difference and dead space/tidal volume ratio in respiratory failure
    • 2 difference and dead space/tidal volume ratio in respiratory failure. Chest 1987;92:832-5.
    • (1987) Chest , vol.92 , pp. 832-835
    • Yamanaka, M.K.1    Sue, D.Y.2
  • 10
    • 0021049394 scopus 로고
    • Transcutaneous monitoring in the newborn infant
    • Cassady G. Transcutaneous monitoring in the newborn infant. J Pediatr 1983;103:837-48.
    • (1983) J. Pediatr. , vol.103 , pp. 837-848
    • Cassady, G.1
  • 11
    • 0018908605 scopus 로고
    • Erythema following transcutaneous PO2 monitoring
    • Boyle RJ, Oh W. Erythema following transcutaneous PO2 monitoring. Pediatrics 1980;65:333-4.
    • (1980) Pediatrics , vol.65 , pp. 333-334
    • Boyle, R.J.1    Oh, W.2
  • 12
    • 0019481691 scopus 로고
    • Skin craters - A complication of transcutaneous oxygen monitoring
    • Golden SM. Skin craters - a complication of transcutaneous oxygen monitoring. Pediatrics 1981;67:514-6.
    • (1981) Pediatrics , vol.67 , pp. 514-516
    • Golden, S.M.1
  • 13
    • 0032518974 scopus 로고    scopus 로고
    • Sample size and optimal designs for reliability studies
    • Walter SD, Eliasziw M. Sample size and optimal designs for reliability studies. Stat Med 1998;17:101-10.
    • (1998) Stat. Med. , vol.17 , pp. 101-110
    • Walter, S.D.1    Eliasziw, M.2
  • 14
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 15
    • 1642451930 scopus 로고    scopus 로고
    • How safe is intermittent positive pressure ventilation in preterm babies ventilated from delivery to newborn intensive care unit?
    • Tracy M, Downe L, Holberton J. How safe is intermittent positive pressure ventilation in preterm babies ventilated from delivery to newborn intensive care unit? Arch Dis Child Fetal Neonatal Ed 2004;89:F84-7.
    • (2004) Arch. Dis. Child Fetal Neonatal Ed. , vol.89
    • Tracy, M.1    Downe, L.2    Holberton, J.3
  • 16
    • 0025684958 scopus 로고
    • Evaluation of a mainstream capnometer and end-tidal carbon dioxide monitoring in mechanically ventilated infants
    • Meredith KS, Monaco FJ. Evaluation of a mainstream capnometer and end-tidal carbon dioxide monitoring in mechanically ventilated infants. Pediatr Pulmon 1990;9:254-9.
    • (1990) Pediatr. Pulmon. , vol.9 , pp. 254-259
    • Meredith, K.S.1    Monaco, F.J.2
  • 18
    • 0019626016 scopus 로고
    • Simultaneous tissue pH and transcutaneous carbon dioxide monitoring in critically ill neonates
    • Bhat R, Kim WD, Shukla A, et al. Simultaneous tissue pH and transcutaneous carbon dioxide monitoring in critically ill neonates. Crit Care Med 1981;9:744.
    • (1981) Crit. Care Med. , vol.9 , pp. 744
    • Bhat, R.1    Kim, W.D.2    Shukla, A.3