메뉴 건너뛰기




Volumn 15, Issue 2, 2004, Pages

The application of a simple algorithm to isotope ratio measurements by gas chromatography/combustion/isotope ratio mass spectrometry

Author keywords

GC C IRMS; Isotope ratio; Mass spectrometry; Ratio calculation

Indexed keywords

ALGORITHMS; COMBUSTION; COMPUTER SOFTWARE; GAS CHROMATOGRAPHY; ISOTOPES; MASS SPECTROMETRY;

EID: 1342333911     PISSN: 09570233     EISSN: None     Source Type: Journal    
DOI: 10.1088/0957-0233/15/2/N02     Document Type: Article
Times cited : (7)

References (9)
  • 1
    • 84989078032 scopus 로고
    • The measurement of stable isotope natural abundance variations
    • Preston T 1992 The measurement of stable isotope natural abundance variations Plant Cell Environ. 15 1091-7
    • (1992) Plant Cell Environ. , vol.15 , pp. 1091-1097
    • Preston, T.1
  • 2
    • 0028473209 scopus 로고
    • Mass-spectrometric analysis of stable-isotope-labeled amino-acid tracers
    • Preston T and Slater C 1994 Mass-spectrometric analysis of stable-isotope-labeled amino-acid tracers Proc. Nutr. Soc. 53 363-72
    • (1994) Proc. Nutr. Soc. , vol.53 , pp. 363-372
    • Preston, T.1    Slater, C.2
  • 3
    • 0028677318 scopus 로고
    • Nitrogen isotopic analyses by isotope-ratio-monitoring gas-chromatography mass-spectrometry
    • Merritt D A and Hayes J M 1994 Nitrogen isotopic analyses by isotope-ratio-monitoring gas-chromatography mass-spectrometry J. Am. Soc. Mass Spectrom. 5 387-97
    • (1994) J. Am. Soc. Mass Spectrom. , vol.5 , pp. 387-397
    • Merritt, D.A.1    Hayes, J.M.2
  • 4
    • 0003117911 scopus 로고
    • Instrumental peak distortion 1. Relaxation time effects
    • McWilliam I and Bolton H 1969 Instrumental peak distortion 1. Relaxation time effects Anal. Chem. 41 1755-62
    • (1969) Anal. Chem. , vol.41 , pp. 1755-1762
    • McWilliam, I.1    Bolton, H.2
  • 5
    • 0028773364 scopus 로고
    • Curve-fitting for restoration of accuracy for overlapping peaks in gas-chromatography combustion isotope ratio mass-spectrometry
    • Goodman K J and Brenna J T 1994 Curve-fitting for restoration of accuracy for overlapping peaks in gas-chromatography combustion isotope ratio mass-spectrometry Anal. Chem. 66 1294-301
    • (1994) Anal. Chem. , vol.66 , pp. 1294-1301
    • Goodman, K.J.1    Brenna, J.T.2
  • 6
    • 0030682193 scopus 로고    scopus 로고
    • Peak measurement in gas chromatographic mass spectrometric isotope studies
    • Bluck L J C and Coward W A 1997 Peak measurement in gas chromatographic mass spectrometric isotope studies J. Mass Spectrom. 32 1212-8
    • (1997) J. Mass Spectrom. , vol.32 , pp. 1212-1218
    • Bluck, L.J.C.1    Coward, W.A.2
  • 7
    • 0032947661 scopus 로고    scopus 로고
    • Applied gas chromatography coupled to isotope ratio mass spectrometry
    • Meier-Augenstein W 1999 Applied gas chromatography coupled to isotope ratio mass spectrometry J. Chromatogr. A 842 351-71
    • (1999) J. Chromatogr. A , vol.842 , pp. 351-371
    • Meier-Augenstein, W.1
  • 8
    • 0029683993 scopus 로고    scopus 로고
    • Measurement of ascorbic-acid kinetics in man using stable isotopes and gas-chromatography mass-spectrometry
    • Bluck L J C, Izzard A P and Bates C J 1996 Measurement of ascorbic-acid kinetics in man using stable isotopes and gas-chromatography mass-spectrometry J. Mass Spectrom. 31 741-8
    • (1996) J. Mass Spectrom. , vol.31 , pp. 741-748
    • Bluck, L.J.C.1    Izzard, A.P.2    Bates, C.J.3
  • 9
    • 39149130115 scopus 로고
    • Isotopic standards for carbon and oxygen and correction factors for mass spectrometric analysis of carbon dioxide
    • Craig H 1957 Isotopic standards for carbon and oxygen and correction factors for mass spectrometric analysis of carbon dioxide Geochim. Cosmochim. Acta 12 133-49
    • (1957) Geochim. Cosmochim. Acta , vol.12 , pp. 133-149
    • Craig, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.