메뉴 건너뛰기




Volumn 12, Issue 3, 2004, Pages 256-259

A new computer-assisted method for measuring the tibio-femoral angle in patients with osteoarthritis of the knee

Author keywords

Computed radiography; Radiographic measurement; Tibio femoral angle

Indexed keywords

ADULT; AGED; ANALYTIC METHOD; ANTERIOR POSTERIOR AXIS; ARTICLE; COMPUTER ANALYSIS; COMPUTER SYSTEM; CONTROLLED STUDY; CORRELATION ANALYSIS; FEMALE; FEMUR; HUMAN; IMAGE ANALYSIS; IMAGE DISPLAY; INTERMETHOD COMPARISON; KNEE OSTEOARTHRITIS; KNEE RADIOGRAPHY; MAJOR CLINICAL STUDY; MALE; MANUAL LABOR; MEASUREMENT; MONITOR; OBSERVER VARIATION; OUTPATIENT; PRIORITY JOURNAL; STANDING; TIBIA; WEIGHT BEARING;

EID: 1342325722     PISSN: 10634584     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.joca.2003.10.005     Document Type: Article
Times cited : (29)

References (15)
  • 1
    • 0025360761 scopus 로고
    • Normal axial alignment of the lower extremity and load-bearing distribution at the knee
    • Hsu RWW, Himeno S, Coventry MB, Chao EYS. Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop 1990;255:215-27.
    • (1990) Clin. Orthop. , vol.255 , pp. 215-227
    • Hsu, R.W.W.1    Himeno, S.2    Coventry, M.B.3    Chao, E.Y.S.4
  • 2
    • 0015303701 scopus 로고
    • A method for quantitative analysis of medial and lateral compression forces at the knee during standing
    • Kettelkamp DB, Chao EY. A method for quantitative analysis of medial and lateral compression forces at the knee during standing. Clin Orthop 1972; 83:202-13.
    • (1972) Clin. Orthop. , vol.83 , pp. 202-213
    • Kettelkamp, D.B.1    Chao, E.Y.2
  • 3
    • 0027453062 scopus 로고
    • Proximal tibial osteotomy. A critical long-term study of eighty-seven cases
    • Coventry MB, Ilstrup DM, Wallrichs SL. Proximal tibial osteotomy. A critical long-term study of eighty-seven cases. J Bone Joint Surg 1993;75-A:196-201.
    • (1993) J. Bone Joint Surg. , vol.75 A , pp. 196-201
    • Coventry, M.B.1    Ilstrup, D.M.2    Wallrichs, S.L.3
  • 4
    • 0023893141 scopus 로고
    • Radiographic assessment of knee alignment after total knee arthroplasty
    • Petersen TL, Engh GA. Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty. 1988;3:67-72.
    • (1988) J. Arthroplasty , vol.3 , pp. 67-72
    • Petersen, T.L.1    Engh, G.A.2
  • 5
    • 0028044658 scopus 로고
    • Post-operative alignment of total knee replacement: Its effect on survival
    • Ritter MA, Faris PM, Keating EM, Meding JB. Post-operative alignment of total knee replacement: its effect on survival. Clin Orthop 1994;299:153-6.
    • (1994) Clin. Orthop. , vol.299 , pp. 153-156
    • Ritter, M.A.1    Faris, P.M.2    Keating, E.M.3    Meding, J.B.4
  • 6
    • 0035460557 scopus 로고    scopus 로고
    • Inter- and intra-observer variability of radiographic measurements of knee alignment
    • Ilahi OA, Kasakia NR, Huo MH. Inter- and intra-observer variability of radiographic measurements of knee alignment. Am J Knee Surg. 2001;14:238-42.
    • (2001) Am. J. Knee Surg. , vol.14 , pp. 238-242
    • Ilahi, O.A.1    Kasakia, N.R.2    Huo, M.H.3
  • 7
    • 84907107526 scopus 로고
    • Filmless digital radiology-feasibility and 20-month experience in clinical routine
    • Mosser H, Urban M, Hruby W. Filmless digital radiology-feasibility and 20-month experience in clinical routine. Med Inform 1994;19:149-59.
    • (1994) Med. Inform. , vol.19 , pp. 149-159
    • Mosser, H.1    Urban, M.2    Hruby, W.3
  • 9
    • 0034222423 scopus 로고    scopus 로고
    • Radiation dose and image information in computed radiography. A phantom study of angle measurements in the weight-bearing knee
    • Sanfridsson J, Holje G, Svahn G, Ryd L, Jonsson K. Radiation dose and image information in computed radiography. A phantom study of angle measurements in the weight-bearing knee. Acta Radiol 2000; 41:310-6.
    • (2000) Acta Radiol. , vol.41 , pp. 310-316
    • Sanfridsson, J.1    Holje, G.2    Svahn, G.3    Ryd, L.4    Jonsson, K.5
  • 10
    • 0025781618 scopus 로고
    • Photostimulable phosphor digital radiography of the extremities: Diagnostic accuracy compared with conventional radiography
    • Wilson AJ, Mann FA, Murphy WA Jr., Monsees BS, Linn MR. Photostimulable phosphor digital radiography of the extremities: diagnostic accuracy compared with conventional radiography. Am J Roentgenol 1991;157:533-8.
    • (1991) Am. J. Roentgenol. , vol.157 , pp. 533-538
    • Wilson, A.J.1    Mann, F.A.2    Murphy Jr., W.A.3    Monsees, B.S.4    Linn, M.R.5
  • 11
    • 0031180458 scopus 로고    scopus 로고
    • Computed radiography for characterization of the weight-bearing knee
    • Sanfridsson J, Svahn G, Jonsson K, Ryd L. Computed radiography for characterization of the weight-bearing knee. Acta Radiol 1997;38:514-9.
    • (1997) Acta Radiol. , vol.38 , pp. 514-519
    • Sanfridsson, J.1    Svahn, G.2    Jonsson, K.3    Ryd, L.4
  • 12
    • 0023221260 scopus 로고
    • Computed radiographic imaging. Use in low-dose leg length radiography
    • Kogutt MS. Computed radiographic imaging. Use in low-dose leg length radiography. Am J Roentgenol 1987;148:1205-6.
    • (1987) Am. J. Roentgenol. , vol.148 , pp. 1205-1206
    • Kogutt, M.S.1
  • 14
    • 0021339071 scopus 로고
    • Alignment of total knee components
    • Laskin LS. Alignment of total knee components. Orthopaedics 1984;7:62-72.
    • (1984) Orthopaedics , vol.7 , pp. 62-72
    • Laskin, L.S.1
  • 15
    • 0025859647 scopus 로고
    • Measurement of lower limb alignment using long radiographs
    • Wright JG, Treble A, Feinstein AR. Measurement of lower limb alignment using long radiographs. J Bone Joint Surg 1991;73-B:721-3.
    • (1991) J. Bone Joint Surg. , vol.73 B , pp. 721-723
    • Wright, J.G.1    Treble, A.2    Feinstein, A.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.