메뉴 건너뛰기




Volumn 25, Issue 1, 2004, Pages 88-90

Effect of elevated-rim acetabular liner and 32-mm femoral head on stability in total hip arthroplasty

Author keywords

[No Author keywords available]

Indexed keywords

ACETABULUM; ADULT; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FEMUR HEAD; HOSPITAL SERVICE; HUMAN; JOINT MOBILITY; JOINT STABILITY; MALE; MEASUREMENT; ORTHOPEDIC EQUIPMENT; STATISTICAL SIGNIFICANCE; TOTAL HIP PROSTHESIS; UNITED STATES;

EID: 1342310740     PISSN: 03795284     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (12)
  • 2
    • 0017058695 scopus 로고
    • Dislocation and instability complicating low friction arthroplasty of the hip joint
    • Eftekhar NS. Dislocation and instability complicating low friction arthroplasty of the hip joint. Clin Orthop 1976; 121: 120-125.
    • (1976) Clin. Orthop. , vol.121 , pp. 120-125
    • Eftekhar, N.S.1
  • 3
    • 0030032266 scopus 로고    scopus 로고
    • The elevated-rim acetabular liner in total hip arthroplasty: Relationship to postoperative dislocation
    • Cobb TK, Morrey BF, Ilstrup DM. The elevated-rim acetabular liner in total hip arthroplasty: relationship to postoperative dislocation. J Bone Joint Surg 1996; 78-A: 80-86.
    • (1996) J. Bone Joint Surg. , vol.78 A , pp. 80-86
    • Cobb, T.K.1    Morrey, B.F.2    Ilstrup, D.M.3
  • 5
    • 0025838237 scopus 로고
    • Elevated-rim acetabular components. Effect on range of motion and stability in total hip arthroplasty
    • Krushell RJ, Burke DW, Harris WH. Elevated-rim acetabular components. Effect on range of motion and stability in total hip arthroplasty. J Arthroplasty 1991; 6 (Suppl 97): S53-S58.
    • (1991) J. Arthroplasty , vol.6 , Issue.SUPPL. 97
    • Krushell, R.J.1    Burke, D.W.2    Harris, W.H.3
  • 6
    • 0025282813 scopus 로고
    • Dislocation of total hip replacements. A comparative study of standard, long posterior wall and augmented acetabular components
    • Nicholas RM, Orr JF, Mollan RAB, Calderwood JW, Nixon JR, Watson P. Dislocation of total hip replacements. A comparative study of standard, long posterior wall and augmented acetabular components. J Bone Joint Surg 1990; 72-B: 418-422.
    • (1990) J. Bone Joint Surg. , vol.72 B , pp. 418-422
    • Nicholas, R.M.1    Orr, J.F.2    Mollan, R.A.B.3    Calderwood, J.W.4    Nixon, J.R.5    Watson, P.6
  • 7
    • 0027310322 scopus 로고
    • Loosening of a femoral stem associated with the use of an extended-lip acetabular cup liner. A case report
    • Bosco JA, Benjamin JB. Loosening of a femoral stem associated with the use of an extended-lip acetabular cup liner. A case report. J Arthroplasty 1993; 8: 91-93.
    • (1993) J. Arthroplasty , vol.8 , pp. 91-93
    • Bosco, J.A.1    Benjamin, J.B.2
  • 8
    • 0030817525 scopus 로고    scopus 로고
    • Effect of the elevated-rim acetabular liner on loosening after total hip arthroplasty
    • Cobb TK, Morrey BF, Ilstrup DM. Effect of the elevated-rim acetabular liner on loosening after total hip arthroplasty. J Bone Joint Surg 1997; 79-A: 1361-1364.
    • (1997) J. Bone Joint Surg. , vol.79 A , pp. 1361-1364
    • Cobb, T.K.1    Morrey, B.F.2    Ilstrup, D.M.3
  • 9
    • 0018093003 scopus 로고
    • Engineering considerations in the design of double-cup hip replacement prostheses
    • Swanson SAV, Mech MI. Engineering considerations in the design of double-cup hip replacement prostheses. Clin Orthop 1978; 134: 12-18.
    • (1978) Clin. Orthop. , vol.134 , pp. 12-18
    • Swanson, S.A.V.1    Mech, M.I.2
  • 10
  • 12


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.