Pitfalls in the diagnosis of acute pulmonary embolism on spiral computer tomography

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANALYTIC METHOD; ARTICLE; ARTIFACT REDUCTION; BREATHING MECHANICS; BRONCHUS MUCUS; CONTRAST ENHANCEMENT; DIAGNOSTIC ACCURACY; DIAGNOSTIC ERROR; DIAGNOSTIC VALUE; FEMALE; HUMAN; IMAGE ENHANCEMENT; LUNG BLOOD VESSEL; LUNG EMBOLISM; LUNG VASCULAR RESISTANCE; MALE; PATHOLOGICAL ANATOMY; PATIENT POSITIONING; SENSITIVITY AND SPECIFICITY; SIGNAL NOISE RATIO; SPIRAL COMPUTER ASSISTED TOMOGRAPHY;

EID: 1342307464     PISSN: 03630188     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cpradiol.2003.11.001     Document Type: Article
Times cited : (23)

References (14)
  • 1
  • 2
    • 0034330627 scopus 로고    scopus 로고
    • Multisection CT: Scanning techniques and clinical applications
    • Rydberg J. Buckwalter K.A. et al. Multisection CT: scanning techniques and clinical applications Radiographics 20 2000 1787-1806
    • (2000) Radiographics , vol.20 , pp. 1787-1806
    • Rydberg, J.1    Buckwalter, K.A.2
  • 3
    • 0036153994 scopus 로고    scopus 로고
    • Subsegmental pulmonary emboli: Improved detection with thin-collimation multi-detector spiral
    • Schoepf U.J. Holzknecht N. Helmberger T.K. et al. Subsegmental pulmonary emboli: Improved detection with thin-collimation multi-detector spiral CT Radiology 222 2002 483-490
    • (2002) Radiology , vol.222 , pp. 483-490
    • Schoepf, U.J.1    Holzknecht, N.2    Helmberger, T.K.3
  • 5
    • 24544461072 scopus 로고    scopus 로고
    • CT evaluation of pulmonary embolism: Significant advances, continuing challenges
    • Fishman JE. CT evaluation of pulmonary embolism: significant advances, continuing challenges. Diagn Imag 2001;Suppl:IR13-16
    • (2001) Diagn. Imag. , Issue.SUPPL.
    • Fishman, J.E.1
  • 6
    • 0030711577 scopus 로고    scopus 로고
    • Pulmonary embolism: Prospective comparison of spiral CT with ventilation-perfusion scintigraphy
    • Mayo J.R. Remy-Jardin M. Muller N.L. et al. Pulmonary embolism: prospective comparison of spiral CT with ventilation-perfusion scintigraphy Radiology 205 1997 447-452
    • (1997) Radiology , vol.205 , pp. 447-452
    • Mayo, J.R.1    Remy-Jardin, M.2    Muller, N.L.3
  • 7
    • 0033752851 scopus 로고    scopus 로고
    • Pulmonary embolism detection: Prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients
    • Qanadli S.D. Hajjam M.E. Mesurolle B. et al. Pulmonary embolism detection: prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients Radiology 217 2000 447-455
    • (2000) Radiology , vol.217 , pp. 447-455
    • Qanadli, S.D.1    Hajjam, M.E.2    Mesurolle, B.3
  • 8
    • 0032254225 scopus 로고    scopus 로고
    • Spiral CT of pulmonary embolism: Diagnostic approach, interpretive pitfalls and current indications
    • Remy-Jardin M. Remy J. Artaud D. et al. Spiral CT of pulmonary embolism: diagnostic approach, interpretive pitfalls and current indications Eur Radiol 8 1998 1376-1390
    • (1998) Eur. Radiol. , vol.8 , pp. 1376-1390
    • Remy-Jardin, M.1    Remy, J.2    Artaud, D.3
  • 9
    • 0031926547 scopus 로고    scopus 로고
    • Unsuspected pulmonary embolism: Prospective detection on routine helical CT scans
    • Gosselin M.V. Rubin G.D. Leung A.N. et al. Unsuspected pulmonary embolism: prospective detection on routine helical CT scans Radiology 208 1998 208-215
    • (1998) Radiology , vol.208 , pp. 208-215
    • Gosselin, M.V.1    Rubin, G.D.2    Leung, A.N.3
  • 10
    • 0026515509 scopus 로고
    • Complications and validity of pulmonary angiography in acute pulmonary embolism
    • Stein P.D. Athanasoulis C. Alavi A. et al. Complications and validity of pulmonary angiography in acute pulmonary embolism Circulation 85 1992 462-468
    • (1992) Circulation , vol.85 , pp. 462-468
    • Stein, P.D.1    Athanasoulis, C.2    Alavi, A.3
  • 11
    • 0030864179 scopus 로고    scopus 로고
    • Depiction of pulmonary emboli with spiral CT: Optimization of display window settings in a porcine model
    • Brink J.A. Woodard P.K. Horesh L. et al. Depiction of pulmonary emboli with spiral CT: optimization of display window settings in a porcine model Radiology 204 1997 703-708
    • (1997) Radiology , vol.204 , pp. 703-708
    • Brink, J.A.1    Woodard, P.K.2    Horesh, L.3
  • 12
    • 0029127974 scopus 로고
    • Hilar lymph nodes: Identification with spiral CT and histologic correlation
    • Remy-Jardin M. Duyck P. Remy J. et al. Hilar lymph nodes: identification with spiral CT and histologic correlation Radiology 196 1995 387-394
    • (1995) Radiology , vol.196 , pp. 387-394
    • Remy-Jardin, M.1    Duyck, P.2    Remy, J.3
  • 14
    • 0034466375 scopus 로고    scopus 로고
    • Helical CT for the evaluation of suspected acute pulmonary embolism: Diagnostic pitfalls
    • Gotway M.B. Patel R.A. Webb W.R. Helical CT for the evaluation of suspected acute pulmonary embolism: diagnostic pitfalls J Comput Assist Tomogr 24 2000 267-273
    • (2000) J. Comput. Assist. Tomogr. , vol.24 , pp. 267-273
    • Gotway, M.B.1    Patel, R.A.2    Webb, W.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.