메뉴 건너뛰기




Volumn 59, Issue 3, 2004, Pages 309-310

Cerebral oximetry and an unanticipated circulatory arrest [14]

Author keywords

[No Author keywords available]

Indexed keywords

CARBON DIOXIDE; DESFLURANE; FENTANYL; HEMOGLOBIN; OXYGEN; PHENYLEPHRINE;

EID: 1342305080     PISSN: 00032409     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1365-2044.2004.03697.x     Document Type: Letter
Times cited : (7)

References (12)
  • 1
    • 0017571334 scopus 로고
    • Noninvasive infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters
    • Jobsis FE. Noninvasive infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science 1977; 198: 1264-7.
    • (1977) Science , vol.198 , pp. 1264-1267
    • Jobsis, F.E.1
  • 3
    • 0002480057 scopus 로고    scopus 로고
    • Theoretical and experimental investigation of near-infrared light propagation in a model of the adult head
    • Okada K, Firbank M, Schweiger M. Theoretical and experimental investigation of near-infrared light propagation in a model of the adult head. Applied Optics 1997; 36: 21-31.
    • (1997) Applied Optics , vol.36 , pp. 21-31
    • Okada, K.1    Firbank, M.2    Schweiger, M.3
  • 4
    • 0003300437 scopus 로고    scopus 로고
    • Maintaining cerebral oxygen saturation during cardiac surgery shortened ICU and hospital stays
    • SCA
    • Yao FS, Levin SK, Wu D. Maintaining cerebral oxygen saturation during cardiac surgery shortened ICU and hospital stays. Anesthesia and Analgesia, 2001: 92: SCA 96.
    • (2001) Anesthesia and Analgesia , vol.92 , pp. 96
    • Yao, F.S.1    Levin, S.K.2    Wu, D.3
  • 6
    • 0032957316 scopus 로고    scopus 로고
    • Retrograde cerebral perfusion versus selective cerebral perfusion as evaluated by oxygen saturation during aortic arch reconstruction
    • Higami T, Kozawa S, Asada T et al. Retrograde cerebral perfusion versus selective cerebral perfusion as evaluated by oxygen saturation during aortic arch reconstruction. Annals of Thoracic Surgery 1999; 67: 1091-6.
    • (1999) Annals of Thoracic Surgery , vol.67 , pp. 1091-1096
    • Higami, T.1    Kozawa, S.2    Asada, T.3
  • 7
    • 0033801501 scopus 로고    scopus 로고
    • Correlation of cerebral oximetry measurement with carotid artery stump pressures during carotid endarterectomy
    • Lee ES, Melnyk DL, Kuskowski MA, Santilli SM. Correlation of cerebral oximetry measurement with carotid artery stump pressures during carotid endarterectomy. Vascular Surgery 2000; 93: 403-9.
    • (2000) Vascular Surgery , vol.93 , pp. 403-409
    • Lee, E.S.1    Melnyk, D.L.2    Kuskowski, M.A.3    Santilli, S.M.4
  • 8
    • 0036100138 scopus 로고    scopus 로고
    • Use of cerebral oximetry to detect and manage cerebral desaturation with a rapidly expanding neck hematoma
    • Acka O. Sessler DI. Use of cerebral oximetry to detect and manage cerebral desaturation with a rapidly expanding neck hematoma. Acta Anaesthesiologica Scandinavica 2002; 46: 607-8.
    • (2002) Acta Anaesthesiologica Scandinavica , vol.46 , pp. 607-608
    • Acka, O.1    Sessler, D.I.2
  • 9
    • 0031127284 scopus 로고    scopus 로고
    • Transcranial cerebral oximetry - Is it clinically useless at this moment to interpret absolute values obtained by the INVOS 3100 cerebral oximeter?
    • Litscher G, Schwarz G. Transcranial cerebral oximetry - is it clinically useless at this moment to interpret absolute values obtained by the INVOS 3100 cerebral oximeter? Biomedizinische Technik (Biomedical Engineering) 1997; 42: 74-7.
    • (1997) Biomedizinische Technik (Biomedical Engineering) , vol.42 , pp. 74-77
    • Litscher, G.1    Schwarz, G.2
  • 10
    • 0032995148 scopus 로고    scopus 로고
    • Cerebral oximetry by near infrared spectroscopy measures cerebral haemoglobin oxygen saturation and the balance between supply and demand, not cerebral blood flow
    • Nemoto EM. Cerebral oximetry by near infrared spectroscopy measures cerebral haemoglobin oxygen saturation and the balance between supply and demand, not cerebral blood flow. British Journal of Neurosurgery 1999; 13: 93-5.
    • (1999) British Journal of Neurosurgery , vol.13 , pp. 93-95
    • Nemoto, E.M.1
  • 11
    • 0036402677 scopus 로고    scopus 로고
    • Multi-modality neurophysiologic monitoring for cardiac surgery
    • Edmonds HL. Multi-modality neurophysiologic monitoring for cardiac surgery. Heart Surgery Forum 2002; 5: 225-8.
    • (2002) Heart Surgery Forum , vol.5 , pp. 225-228
    • Edmonds, H.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.