메뉴 건너뛰기




Volumn 18, Issue 2, 2004, Pages 188-191

Endoscopic visualisation to aid deep anterior lamellar keratoplasty

Author keywords

Air dissection; DALK; Endoscopic; Keratoplasty

Indexed keywords

ANTERIOR EYE CHAMBER; ARTICLE; CONTROLLED STUDY; CORNEA STROMA; DESCEMET MEMBRANE; ENDOSCOPE; ENDOSCOPIC SURGERY; HUMAN; IMAGING SYSTEM; KERATOPLASTY; SURGICAL APPROACH; SURGICAL TECHNIQUE;

EID: 1342303846     PISSN: 0950222X     EISSN: None     Source Type: Journal    
DOI: 10.1038/sj.eye.6700601     Document Type: Article
Times cited : (11)

References (12)
  • 1
    • 0036186504 scopus 로고    scopus 로고
    • Big-bubble technique to bare Descemet's membrane in anterior lamellar keratoplasty
    • Anwar M, Teichmann KD. Big-bubble technique to bare Descemet's membrane in anterior lamellar keratoplasty. J Cataract Refract Surg 2002; 28(3): 398-403.
    • (2002) J. Cataract. Refract. Surg. , vol.28 , Issue.3 , pp. 398-403
    • Anwar, M.1    Teichmann, K.D.2
  • 2
    • 0021570097 scopus 로고
    • Deep lamellar keratoplasty dissection of host tissue with intrastromal air injection
    • Archila EA. Deep lamellar keratoplasty dissection of host tissue with intrastromal air injection. Cornea 1984; 3: 217-218.
    • (1984) Cornea , vol.3 , pp. 217-218
    • Archila, E.A.1
  • 4
    • 1342277810 scopus 로고    scopus 로고
    • Posterior lamellar keratoplasty
    • Melles GR. Posterior lamellar keratoplasty. Arch Soc Esp Oftalmol 2002; 77: 175-176.
    • (2002) Arch. Soc. Esp. Oftalmol. , vol.77 , pp. 175-176
    • Melles, G.R.1
  • 5
    • 0036199342 scopus 로고    scopus 로고
    • Sutureless, posterior lamellar keratoplasty: A case report of a modified technique
    • Melles GR, Lander F, Nieuwendaal C. Sutureless, posterior lamellar keratoplasty: a case report of a modified technique. Cornea 2002; 21: 325-327.
    • (2002) Cornea , vol.21 , pp. 325-327
    • Melles, G.R.1    Lander, F.2    Nieuwendaal, C.3
  • 6
    • 0036234416 scopus 로고    scopus 로고
    • Transplantation of Descemet's membrane carrying viable endothelium through a small scleral incision
    • Melles GR, Lander F, Rietveld FJ. Transplantation of Descemet's membrane carrying viable endothelium through a small scleral incision. Cornea 2002; 21: 415-418.
    • (2002) Cornea , vol.21 , pp. 415-418
    • Melles, G.R.1    Lander, F.2    Rietveld, F.J.3
  • 7
    • 85046913824 scopus 로고    scopus 로고
    • Comment on transplantation of Descemet's membrane carrying viable endothelium through a small scleral incision
    • Sharma A, Woodman A. Comment on transplantation of Descemet's membrane carrying viable endothelium through a small scleral incision. Cornea 2000; 21(8): 840.
    • (2000) Cornea , vol.21 , Issue.8 , pp. 840
    • Sharma, A.1    Woodman, A.2
  • 8
    • 0035139337 scopus 로고    scopus 로고
    • An ocular endoscope enables a goniotomy despite a cloudy cornea
    • Joos KM, Shen JH. An ocular endoscope enables a goniotomy despite a cloudy cornea. Arch Ophthalmol 2001; 119: 134-135.
    • (2001) Arch. Ophthalmol. , vol.119 , pp. 134-135
    • Joos, K.M.1    Shen, J.H.2
  • 9
    • 0035124887 scopus 로고    scopus 로고
    • Endoscopic vitreoretinal surgery for complicated proliferative diabetic retinopathy
    • Ciardella AP, Fisher YL, Carvalho C et al. Endoscopic vitreoretinal surgery for complicated proliferative diabetic retinopathy. Retina 2001; 21: 20-27.
    • (2001) Retina , vol.21 , pp. 20-27
    • Ciardella, A.P.1    Fisher, Y.L.2    Carvalho, C.3
  • 10
    • 0033406422 scopus 로고    scopus 로고
    • Application of a newly developed, highly sensitive camera and a 3-dimensional high-definition television system in experimental ophthalmic surgeries
    • Miyake K, Ota I, Miyake S, Tanioka K, Kubota M, Mochizuki R. Application of a newly developed, highly sensitive camera and a 3-dimensional high-definition television system in experimental ophthalmic surgeries. Arch Ophthalmol 1999; 117: 1623-1629.
    • (1999) Arch. Ophthalmol. , vol.117 , pp. 1623-1629
    • Miyake, K.1    Ota, I.2    Miyake, S.3    Tanioka, K.4    Kubota, M.5    Mochizuki, R.6
  • 11
    • 0032758670 scopus 로고    scopus 로고
    • Three-dimensional (3-D) video systems: Bi-channel or single-channel optics?
    • van Bergen P, Kunert W, Buess GF. Three-dimensional (3-D) video systems: bi-channel or single-channel optics? Endoscopy 1999; 3: 732-737.
    • (1999) Endoscopy , vol.3 , pp. 732-737
    • van Bergen, P.1    Kunert, W.2    Buess, G.F.3
  • 12
    • 0036518734 scopus 로고    scopus 로고
    • A new stereoscopic endoscopy system: Accurate 3-dimensional measurement in vitro and in vivo with distortion-correction function
    • Yao K, Matsui T, Furukawa H, Yao T, Sakurai T, Mitsuyasu T. A new stereoscopic endoscopy system: accurate 3-dimensional measurement in vitro and in vivo with distortion-correction function. Gastrointest Endosc 2002; 55: 412-420.
    • (2002) Gastrointest Endosc. , vol.55 , pp. 412-420
    • Yao, K.1    Matsui, T.2    Furukawa, H.3    Yao, T.4    Sakurai, T.5    Mitsuyasu, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.