메뉴 건너뛰기




Volumn 5140, Issue , 2003, Pages 125-132

Application of optical coherence tomography for diagnosis and measurements of glycated hemoglobin

Author keywords

Glycated hemoglobin; Optical coherence tomography; Refractive index

Indexed keywords

BLOOD; DIAGNOSIS; GLUCOSE; HEMOGLOBIN; LIGHT SCATTERING; REFRACTIVE INDEX;

EID: 1342288725     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.500532     Document Type: Conference Paper
Times cited : (7)

References (28)
  • 2
    • 0035153678 scopus 로고    scopus 로고
    • Advanced glycation end products, their receptors and diabetic angiopathy
    • J.L. Wautier, P.J. Guillausseau, "Advanced glycation end products, their receptors and diabetic angiopathy," Diabetes Metab. 27, 535-542, 2001.
    • (2001) Diabetes Metab. , vol.27 , pp. 535-542
    • Wautier, J.L.1    Guillausseau, P.J.2
  • 3
    • 0036525878 scopus 로고    scopus 로고
    • Properties of erythrocyte light refraction in diabetic patients
    • G. Mazarevica, T. Freivalds, A. Jurka, "Properties of erythrocyte light refraction in diabetic patients," J. Biomed. Opt. 7, 244-247, 2002.
    • (2002) J. Biomed. Opt. , vol.7 , pp. 244-247
    • Mazarevica, G.1    Freivalds, T.2    Jurka, A.3
  • 5
    • 0037077797 scopus 로고    scopus 로고
    • Glycated hemoglobin: A useful post-mortem reference marker in determining diabetes
    • J.P. Goulle, C. Lacroix, D. Bouige, "Glycated hemoglobin: a useful post-mortem reference marker in determining diabetes," Forensic. Sci. Int. 128, 44-49, 2002.
    • (2002) Forensic. Sci. Int. , vol.128 , pp. 44-49
    • Goulle, J.P.1    Lacroix, C.2    Bouige, D.3
  • 7
    • 0036741885 scopus 로고    scopus 로고
    • High and low hemoglobin glycation phenotypes in type 1 diabetes. A challenge for interpretation of glycemic control
    • J. Hempe, R. Gomez, R. McCarter, S. Chalew, "High and low hemoglobin glycation phenotypes in type 1 diabetes. A challenge for interpretation of glycemic control," J. Diabetes Complications 16, 313, 2002.
    • (2002) J. Diabetes Complications , vol.16 , pp. 313
    • Hempe, J.1    Gomez, R.2    McCarter, R.3    Chalew, S.4
  • 8
    • 0018547911 scopus 로고
    • Hemoglobin A1c values in children with Overt diabetes maintained in varying degrees of control
    • R.L. Jackson, R.L. Hess, J.D. England, "Hemoglobin A1c values in children with Overt diabetes maintained in varying degrees of control," Diabetes Care 2, 391-395, 1979.
    • (1979) Diabetes Care , vol.2 , pp. 391-395
    • Jackson, R.L.1    Hess, R.L.2    England, J.D.3
  • 10
    • 0032714683 scopus 로고    scopus 로고
    • Optical properties of circulating human blood in the waveleght Range 400-2500nm
    • A. Roggan, M. Friebel, K. Dorschel, A. Hahn, G. Muller, "Optical Properties of Circulating Human Blood in the Waveleght Range 400-2500nm," J. Biomed. Opt. 4, 36-46, 1999.
    • (1999) J. Biomed. Opt. , vol.4 , pp. 36-46
    • Roggan, A.1    Friebel, M.2    Dorschel, K.3    Hahn, A.4    Muller, G.5
  • 11
    • 0031185616 scopus 로고    scopus 로고
    • Monte Carlo modeling studies of the effect of physiological factors and other analytes on the determination of glucose concentration in vivo by near infrared optical absorption and scattering measurements
    • J.Qu, B.C.Wilson, "Monte Carlo Modeling Studies of the Effect of Physiological Factors and Other Analytes on the Determination of Glucose Concentration In Vivo by Near Infrared Optical Absorption and Scattering Measurements," J. Biomed. Opt. 2, 319-325, 1997.
    • (1997) J. Biomed. Opt. , vol.2 , pp. 319-325
    • Qu, J.1    Wilson, B.C.2
  • 12
    • 0000869903 scopus 로고    scopus 로고
    • Correlation between blood glucose concentration in diabetics and noninvasively measured tissue optical scattering coefficient
    • J.T. Bruulsema, J.E. Hayward, T.J. Farrell et al., "Correlation between blood glucose concentration in diabetics and noninvasively measured tissue optical scattering coefficient," Opt. Lett. 22, 190-192, 1997.
    • (1997) Opt. Lett. , vol.22 , pp. 190-192
    • Bruulsema, J.T.1    Hayward, J.E.2    Farrell, T.J.3
  • 13
    • 0034789744 scopus 로고    scopus 로고
    • Use of osmotically active agents to alter optical properties of tissue: Effects on the detected fluorescence signal measured through skin
    • G. Vargas, K.F. Chan, S.L. Thomsen, A.J. Welch, "Use of Osmotically Active Agents to Alter Optical Properties of Tissue: Effects on the Detected Fluorescence Signal Measured Through Skin," Lasers Surg. Med. 29, 213-220, 2001.
    • (2001) Lasers Surg. Med. , vol.29 , pp. 213-220
    • Vargas, G.1    Chan, K.F.2    Thomsen, S.L.3    Welch, A.J.4
  • 14
    • 0041929010 scopus 로고    scopus 로고
    • The action of osmotically active drugs on optical properties of skin and state of microcirculation in experiments
    • E.I. Galanzha, V.V. Tuchin, Q. Luo, H. Cheng, A.V. Solov'eva, "The action of osmotically active drugs on optical properties of skin and state of microcirculation in experiments," Asian J. Phys. 10, 2001.
    • (2001) Asian J. Phys. , vol.10
    • Galanzha, E.I.1    Tuchin, V.V.2    Luo, Q.3    Cheng, H.4    Solov'eva, A.V.5
  • 15
    • 0035186554 scopus 로고    scopus 로고
    • Dynamic optical coherence tomography of blood layer
    • in Imaging of Tissue Structure and Function, V.V. Tuchin, Q. Luo and S.S. Ulyanov, eds.
    • V.V. Tuchin, X. Xu, R.K. Wang, "Dynamic optical coherence tomography of blood layer," in Imaging of Tissue Structure and Function, V.V. Tuchin, Q. Luo and S.S. Ulyanov, eds., Proc SPIE 4427, 47-52, 2001.
    • (2001) Proc SPIE , vol.4427 , pp. 47-52
    • Tuchin, V.V.1    Xu, X.2    Wang, R.K.3
  • 16
    • 0036017339 scopus 로고    scopus 로고
    • Dynamic optical coherence tomography in optical clearing, sedimentation and aggregation study of immersed blood
    • V.V. Tuchin, X. Xu, and R.K. Wang, "Dynamic optical coherence tomography in optical clearing, sedimentation and aggregation study of immersed blood," Appl. Opt. 41 (1), 258-271, 2002.
    • (2002) Appl. Opt. , vol.41 , Issue.1 , pp. 258-271
    • Tuchin, V.V.1    Xu, X.2    Wang, R.K.3
  • 17
    • 0000186093 scopus 로고    scopus 로고
    • Noninvasive monitoring of glucose concentration with optical coherence tomography
    • R.O. Esenaliev, K.V. Larin, IV. Larina, M. Motamedi, "Noninvasive monitoring of glucose concentration with optical coherence tomography," Opt. Lett. 26, 992-994, 2001.
    • (2001) Opt. Lett. , vol.26 , pp. 992-994
    • Esenaliev, R.O.1    Larin, K.V.2    Larina, I.V.3    Motamedi, M.4
  • 18
    • 0000315830 scopus 로고
    • Refractometry of living cells
    • R. Barer, K.F.A. Ross and S. Tkaczyk, "Refractometry of living cells," Nature 171, 720-724, 1953.
    • (1953) Nature , vol.171 , pp. 720-724
    • Barer, R.1    Ross, K.F.A.2    Tkaczyk, S.3
  • 19
    • 0033624456 scopus 로고    scopus 로고
    • Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomography
    • A. Knuettel and M. Boehlau-Godau, "Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomography," J. Biomed. Opt. 5, 83-92, 2000.
    • (2000) J. Biomed. Opt. , vol.5 , pp. 83-92
    • Knuettel, A.1    Boehlau-Godau, M.2
  • 20
    • 0003601061 scopus 로고
    • D.N. Sci diss., Institute of Biomedical Engineering, Zurich, Switzerland
    • P.O. Rol, Optics for Transscleral Laser Applications, D.N. Sci diss., Institute of Biomedical Engineering, Zu. rich, Switzerland, 1992.
    • (1992) Optics for Transscleral Laser Applications
    • Rol, P.O.1
  • 21
    • 0028731080 scopus 로고
    • Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissues in the near infrared
    • J.S. Maier, S.A. Walker, S. Fantini, M.A. Franceschini, and E. Gratton, 'Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissues in the near infrared,' Opt. Lett. 19, 2062-2064, 1994.
    • (1994) Opt. Lett. , vol.19 , pp. 2062-2064
    • Maier, J.S.1    Walker, S.A.2    Fantini, S.3    Franceschini, M.A.4    Gratton, E.5
  • 22
    • 0028730887 scopus 로고
    • Influence of glucose concentration on light scattering in tissue simulating phantoms
    • M. Kohl, M. Cope, M. Essenpreis, and D. Bocker, 'Influence of glucose concentration on light scattering in tissue simulating phantoms,' Opt. Lett. 19, 2170-2172, 1994.
    • (1994) Opt. Lett. , vol.19 , pp. 2170-2172
    • Kohl, M.1    Cope, M.2    Essenpreis, M.3    Bocker, D.4
  • 25
    • 1342312851 scopus 로고    scopus 로고
    • Dependence of the index of refraction of hemoglobin solutions on oxygen saturation
    • FORTH IESL, Crete, Greece, Abstracts, 3
    • D. Faber, "Dependence of the index of refraction of hemoglobin solutions on oxygen saturation," Biophotonics-2002, FORTH IESL, Crete, Greece, Abstracts, 3, 2002.
    • (2002) Biophotonics-2002
    • Faber, D.1
  • 27
    • 0033086268 scopus 로고    scopus 로고
    • Measuring glycated proteins: Clinical and methodological aspects
    • M.P. Cohen, R.S. Clements, "Measuring glycated proteins: clinical and methodological aspects," Diabetes Technol. Ther. 1, 57-70, 1999.
    • (1999) Diabetes Technol. Ther. , vol.1 , pp. 57-70
    • Cohen, M.P.1    Clements, R.S.2
  • 28
    • 0031892091 scopus 로고    scopus 로고
    • Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulin
    • D.W. Schmidtke, A.C. Freeland, A. Heller and R.T. Bonnecaze, "Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulin," Proc. Natl. Acad. Sci. 95, 294-299, 1998.
    • (1998) Proc. Natl. Acad. Sci. , vol.95 , pp. 294-299
    • Schmidtke, D.W.1    Freeland, A.C.2    Heller, A.3    Bonnecaze, R.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.