-
1
-
-
0023457269
-
The response of the seated human to sinusoidal vibration and impact
-
Pope, M.H., Wilder, D.G., Jorneus, L., Broman, H., Svensson, M., and Andersson, G.B.J., "The Response of the Seated Human to Sinusoidal Vibration and Impact." Journal of Biomechanical Engineering, 109, 279-284 (1987).
-
(1987)
Journal of Biomechanical Engineering
, vol.109
, pp. 279-284
-
-
Pope, M.H.1
Wilder, D.G.2
Jorneus, L.3
Broman, H.4
Svensson, M.5
Andersson, G.B.J.6
-
3
-
-
1342333881
-
Measurement of implant stability and osseintegration: Non-linearities and resonance frequencies
-
Denayer, I., Jaeques, S.V.N., Burny, F., Puers, R., Borgwardt, A., and Van der Perre, G., "Measurement of Implant Stability and Osseintegration: Non-linearities and Resonance Frequencies." Proceedings of the 12th Conference of the European Society of Biomechanics, Dublin, 151 (2000).
-
(2000)
Proceedings of the 12th Conference of the European Society of Biomechanics, Dublin
, pp. 151
-
-
Denayer, I.1
Jaeques, S.V.N.2
Burny, F.3
Puers, R.4
Borgwardt, A.5
Van der Perre, G.6
-
4
-
-
2942522197
-
Experimental validation of an orthotropic FE model using modal analysis
-
Klabunde, R., Roland, E., Taylor, W.R., Clift, S.E., and Rakotomanana, L., "Experimental Validation of an Orthotropic FE Model Using Modal Analysis, "Proceedings of the 12th Conference of the European Society of Biomechanics, Dublin, 454 (2000).
-
(2000)
Proceedings of the 12th Conference of the European Society of Biomechanics, Dublin
, pp. 454
-
-
Klabunde, R.1
Roland, E.2
Taylor, W.R.3
Clift, S.E.4
Rakotomanana, L.5
-
6
-
-
0024863168
-
Synthetic composite femurs for use in evaluation of torsional stability of cementless femoral prosthesis
-
P. A. Torzilli and M. H. Friedman, editors, ASME AMD
-
Bianco, P.T., Bechtold, J.E., Kyle, R.F., and Gustilo, R.B., "Synthetic Composite Femurs for Use in Evaluation of Torsional Stability of Cementless Femoral Prosthesis," Proceedings of the Biomechanics Symposium. P. A. Torzilli and M. H. Friedman, editors, ASME AMD, 297-300 (1989).
-
(1989)
Proceedings of the Biomechanics Symposium
, pp. 297-300
-
-
Bianco, P.T.1
Bechtold, J.E.2
Kyle, R.F.3
Gustilo, R.B.4
-
7
-
-
0030131155
-
Mechanical validation of whole bone composite femur-models
-
Cristofolini, L., Viceconti, M., Cappello, A., and Toni, A., "Mechanical Validation of Whole Bone Composite Femur-Models," Journal of Biomechanics, 29 (4), 525-535 (1996).
-
(1996)
Journal of Biomechanics
, vol.29
, Issue.4
, pp. 525-535
-
-
Cristofolini, L.1
Viceconti, M.2
Cappello, A.3
Toni, A.4
-
8
-
-
0026131363
-
Comparison of the stability of press-fit hip prosthesis femoral stems using a synthetic model femur
-
McKellop, H., Ebramzdeh, E., Niederer, P.G., and Sarmiento, A., "Comparison of the Stability of Press-Fit Hip Prosthesis Femoral Stems Using a Synthetic Model Femur," Journal of Orthopedic Research, 9, 297-305 (1991).
-
(1991)
Journal of Orthopedic Research
, vol.9
, pp. 297-305
-
-
McKellop, H.1
Ebramzdeh, E.2
Niederer, P.G.3
Sarmiento, A.4
-
9
-
-
0002834055
-
Experimental and numerical pre-clinical evaluation relating to total hip arthroplasty
-
J. Middleton, editor, Gordon and Breach, the Netherlands
-
McNamara, B.P., Viceconti, M., Cristofolini, L., Toni, A., and Taylor, D., "Experimental and Numerical Pre-clinical Evaluation Relating to Total Hip Arthroplasty," Proceedings of the 2nd International Symposium on Computer Methods in Biomechanics and Biomedical Engineering, J. Middleton, editor, Gordon and Breach, the Netherlands, 1-10 (1996).
-
(1996)
Proceedings of the 2nd International Symposium on Computer Methods in Biomechanics and Biomedical Engineering
, pp. 1-10
-
-
McNamara, B.P.1
Viceconti, M.2
Cristofolini, L.3
Toni, A.4
Taylor, D.5
-
10
-
-
0027605117
-
Strain distribution in the proximal femur with flexible composite and metallic femoral components under axial and torsional loads
-
Otani, T., Whiteside, L.A., and White, S.E., "Strain Distribution in the Proximal Femur with Flexible Composite and Metallic Femoral Components Under Axial and Torsional Loads," Journal of Biomedical Material Research, 27, 575 (1993).
-
(1993)
Journal of Biomedical Material Research
, vol.27
, pp. 575
-
-
Otani, T.1
Whiteside, L.A.2
White, S.E.3
-
11
-
-
0012054912
-
Variability in the torsional and bending response of a commercially available composite femur
-
Szivek, J.A., Weng, M., and Karpman, R., "Variability in the Torsional and Bending Response of a Commercially Available Composite Femur," Journal of Applied Biomaterials, 1, 183-186 (1990).
-
(1990)
Journal of Applied Biomaterials
, vol.1
, pp. 183-186
-
-
Szivek, J.A.1
Weng, M.2
Karpman, R.3
-
12
-
-
0026311111
-
Comparison of the deformation response of synthetic and cadaveric femora during simulated one-legged stance
-
Szivek, J.A. and Gealer, R.L., "Comparison of the Deformation Response of Synthetic and Cadaveric Femora During Simulated One-Legged Stance," Journal of Applied Biomaterials, 2, 277-280 (1991).
-
(1991)
Journal of Applied Biomaterials
, vol.2
, pp. 277-280
-
-
Szivek, J.A.1
Gealer, R.L.2
-
13
-
-
0027078729
-
Development of synthetic bone models for the evaluation of fracture fixation devices
-
Uta, S., "Development of Synthetic Bone Models for the Evaluation of Fracture Fixation Devices," Nippon Seikegeka Gakkai Zasshi, 66 (11), 1156-1164 (1992).
-
(1992)
Nippon Seikegeka Gakkai Zasshi
, vol.66
, Issue.11
, pp. 1156-1164
-
-
Uta, S.1
-
14
-
-
0030229783
-
The 'standardized femur program'. Proposal for a reference geometry to be used for the creation of finite element models of the femur
-
Viceconti, M., Casali, M., Massari, B., Cristofolini, L., Bassini, S., and Toni, A., "The 'Standardized Femur Program'. Proposal for a Reference Geometry to be Used for the Creation of Finite Element Models of the Femur," Journal of Biomechanics, 29, 1241 (1996).
-
(1996)
Journal of Biomechanics
, vol.29
, pp. 1241
-
-
Viceconti, M.1
Casali, M.2
Massari, B.3
Cristofolini, L.4
Bassini, S.5
Toni, A.6
|