메뉴 건너뛰기




Volumn 98, Issue 2-3, 2004, Pages 115-121

A novel renewable plant tissue-based electrochemiluminescent biosensor for glycolic acid

Author keywords

Biosensor; Electrochemiluminescence; Flow injection analysis; Glycolic acid; Luminol; Plant tissue

Indexed keywords

CHEMILUMINESCENCE; ELECTROLUMINESCENCE; ELECTROLYSIS; ENZYMES; GAS CHROMATOGRAPHY; HYDROGEN PEROXIDE; ORGANIC ACIDS; TISSUE;

EID: 1342264300     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(03)00640-3     Document Type: Article
Times cited : (11)

References (27)
  • 2
    • 0012284480 scopus 로고
    • Colorimetric determination of glycolic acid with β-naphthol
    • Viccaro J.P., Ambye E.L. Colorimetric determination of glycolic acid with β-naphthol. Microchem. J. 17:1972;710-718.
    • (1972) Microchem. J. , vol.17 , pp. 710-718
    • Viccaro, J.P.1    Ambye, E.L.2
  • 3
    • 0026684318 scopus 로고
    • Comparison of two extraction procedures for urinary organic acids prior to gas chromatography-mass spectrometry
    • Mardens Y., Kumps A., Planchon C., Wurth C. Comparison of two extraction procedures for urinary organic acids prior to gas chromatography-mass spectrometry. J. Chromatogr. 577:1992;341-345.
    • (1992) J. Chromatogr. , vol.577 , pp. 341-345
    • Mardens, Y.1    Kumps, A.2    Planchon, C.3    Wurth, C.4
  • 4
    • 0032488849 scopus 로고    scopus 로고
    • Determination of glycolic acid in cosmetic products by solid-phase extraction and reversed-phase ion-pair high performance liquid chromatography
    • Scalia S., Callegari R., Villani S. Determination of glycolic acid in cosmetic products by solid-phase extraction and reversed-phase ion-pair high performance liquid chromatography. J. Chromatogr. A. 795:1998;219-225.
    • (1998) J. Chromatogr. A , vol.795 , pp. 219-225
    • Scalia, S.1    Callegari, R.2    Villani, S.3
  • 5
    • 0028022672 scopus 로고
    • An amperometric bi-enzyme sensor for glycolic acid determination based on spinach tissue and ferrocence-mediation
    • Oungpipat W., Alexander P.W. An amperometric bi-enzyme sensor for glycolic acid determination based on spinach tissue and ferrocence-mediation. Anal. Chim. Acta. 295:1994;37-46.
    • (1994) Anal. Chim. Acta , vol.295 , pp. 37-46
    • Oungpipat, W.1    Alexander, P.W.2
  • 6
    • 0035866657 scopus 로고    scopus 로고
    • Plant tissue-based chemiluminescence flow biosensor for glycoolic acid
    • Li B., Zhang Z., Jin Y. Plant tissue-based chemiluminescence flow biosensor for glycoolic acid. Anal. Chem. 73:2001;1203-1206.
    • (2001) Anal. Chem. , vol.73 , pp. 1203-1206
    • Li, B.1    Zhang, Z.2    Jin, Y.3
  • 7
    • 0032513097 scopus 로고    scopus 로고
    • Liquid chromatography with luminol-based electrochemiluminscence detection determination of histamine
    • Steijger O.M., Kamminga D.A., Brummelhuis A., Lingeman H. Liquid chromatography with luminol-based electrochemiluminscence detection determination of histamine. J. Chromatogr. A. 799:1998;57-66.
    • (1998) J. Chromatogr. A , vol.799 , pp. 57-66
    • Steijger, O.M.1    Kamminga, D.A.2    Brummelhuis, A.3    Lingeman, H.4
  • 8
    • 0000539864 scopus 로고
    • Investigation of electrochemiluminescence of luminol in aqueous alkaline solution
    • An J., Chen X., Chen H. Investigation of electrochemiluminescence of luminol in aqueous alkaline solution. Chin. J. Anal. Chem. 16:1988;127-132.
    • (1988) Chin. J. Anal. Chem. , vol.16 , pp. 127-132
    • An, J.1    Chen, X.2    Chen, H.3
  • 9
    • 0002181101 scopus 로고
    • Determination of sub-nmol hydrogen peroxide by electrochemiluminscence of luminol in aqueous solution
    • Sakura S., Imai H. Determination of sub-nmol hydrogen peroxide by electrochemiluminscence of luminol in aqueous solution. Anal. Sci. 4:1988;9-12.
    • (1988) Anal. Sci. , vol.4 , pp. 9-12
    • Sakura, S.1    Imai, H.2
  • 10
    • 0026607189 scopus 로고
    • Electrochemiluminescence of hydrogen peroxide-luminol at a carbon electrode
    • Sakura S. Electrochemiluminescence of hydrogen peroxide-luminol at a carbon electrode. Anal. Chim. Acta. 262:1992;49-57.
    • (1992) Anal. Chim. Acta , vol.262 , pp. 49-57
    • Sakura, S.1
  • 11
    • 0001423553 scopus 로고    scopus 로고
    • An electrogenerated chemiluminescence probe and its application utilizing tris (2,2′-bipyridyl) ruthenium and luminol chemiluminescence without a flowing stream
    • Preston J.P., Nieman T.A. An electrogenerated chemiluminescence probe and its application utilizing tris (2,2′-bipyridyl) ruthenium and luminol chemiluminescence without a flowing stream. Anal. Chem. 68:1996;966-970.
    • (1996) Anal. Chem. , vol.68 , pp. 966-970
    • Preston, J.P.1    Nieman, T.A.2
  • 12
    • 0030578377 scopus 로고    scopus 로고
    • Electroluminescent detection of enzymatically generated hydrogen peroxide
    • Laespada M.E.F., Pavon J.L.P., Cordero B.M. Electroluminescent detection of enzymatically generated hydrogen peroxide. Anal. Chim. Acta. 327:1996;253-260.
    • (1996) Anal. Chim. Acta , vol.327 , pp. 253-260
    • Laespada, M.E.F.1    Pavon, J.L.P.2    Cordero, B.M.3
  • 14
    • 0032927649 scopus 로고    scopus 로고
    • A review of recent trends in analytical applications of electrogenerated chemiluminescence
    • Knight A.W. A review of recent trends in analytical applications of electrogenerated chemiluminescence. Trends Anal. Chem. 18:1999;47-62.
    • (1999) Trends Anal. Chem. , vol.18 , pp. 47-62
    • Knight, A.W.1
  • 15
    • 0037830049 scopus 로고    scopus 로고
    • Recent applications of electrogenerated chemiluminescence in chemical analysis
    • Fahnrich K.A., Pravda M., Guilbault G.G. Recent applications of electrogenerated chemiluminescence in chemical analysis. Talanta. 54:2001;531-559.
    • (2001) Talanta , vol.54 , pp. 531-559
    • Fahnrich, K.A.1    Pravda, M.2    Guilbault, G.G.3
  • 16
    • 0034120173 scopus 로고    scopus 로고
    • Luminol electrochemiluminescence-based biosensor for total cholesterol determination in natural samples
    • Marquette C.A., Ravaud S., Blum L.J. Luminol electrochemiluminescence-based biosensor for total cholesterol determination in natural samples. Anal. Lett. 33:2000;1779-1796.
    • (2000) Anal. Lett. , vol.33 , pp. 1779-1796
    • Marquette, C.A.1    Ravaud, S.2    Blum, L.J.3
  • 17
    • 0032967364 scopus 로고    scopus 로고
    • Luminol electrochemiluminescence-based fiber optical biosensors for flow injection analysis of glucose and lactate in natural samples
    • Marquette C.A., Blum L.J. Luminol electrochemiluminescence-based fiber optical biosensors for flow injection analysis of glucose and lactate in natural samples. Anal. Chim. Acta. 381:1999;1-10.
    • (1999) Anal. Chim. Acta , vol.381 , pp. 1-10
    • Marquette, C.A.1    Blum, L.J.2
  • 18
    • 0033964870 scopus 로고    scopus 로고
    • An electrochemiluminescence-based fiber optical biosensor for choline flow injection analysis
    • Tsafack V.C., Marquette C.A., Leca B., Blum L.J. An electrochemiluminescence-based fiber optical biosensor for choline flow injection analysis. Analyst. 125:2000;151-155.
    • (2000) Analyst , vol.125 , pp. 151-155
    • Tsafack, V.C.1    Marquette, C.A.2    Leca, B.3    Blum, L.J.4
  • 20
    • 0343157662 scopus 로고    scopus 로고
    • Electrochemiluminescence detection of glucose oxidase as a model for flow injection immunoassays
    • Wilson R., Kremeskotter J., Schiffrin D.J. Electrochemiluminescence detection of glucose oxidase as a model for flow injection immunoassays. Biosens. Bioelectron. 11:1996;805-810.
    • (1996) Biosens. Bioelectron. , vol.11 , pp. 805-810
    • Wilson, R.1    Kremeskotter, J.2    Schiffrin, D.J.3
  • 21
    • 0034032566 scopus 로고    scopus 로고
    • Luminol electrochemiluminescence with screen-printed electrodes for low-cost disposable oxidase-based optical sensors
    • Leca B., Blum L.J. Luminol electrochemiluminescence with screen-printed electrodes for low-cost disposable oxidase-based optical sensors. Analyst. 125:2000;789-791.
    • (2000) Analyst , vol.125 , pp. 789-791
    • Leca, B.1    Blum, L.J.2
  • 22
    • 0037095340 scopus 로고    scopus 로고
    • Electrochemiluminescent determination of glucose with a sol-gel derived ceramic-carbon composite electrode as a renewable optical fiber biosensor
    • Zhu L., Li Y., Tian F., Xu B., Zhu G. Electrochemiluminescent determination of glucose with a sol-gel derived ceramic-carbon composite electrode as a renewable optical fiber biosensor. Sens. Actuators B. 84:2002;265-300.
    • (2002) Sens. Actuators B , vol.84 , pp. 265-300
    • Zhu, L.1    Li, Y.2    Tian, F.3    Xu, B.4    Zhu, G.5
  • 23
    • 84987492148 scopus 로고
    • Carbon paste electrodes modified with enzymes, tissues, and cells
    • Gorton L. Carbon paste electrodes modified with enzymes, tissues, and cells. Electroanalysis. 7:1995;23-45.
    • (1995) Electroanalysis , vol.7 , pp. 23-45
    • Gorton, L.1
  • 26
    • 0347120700 scopus 로고    scopus 로고
    • Plant tissue-based chemiluminescence flow biosensor for the determination of oxalate
    • Peng Y.Y., Qin W., Zhang Z.J. Plant tissue-based chemiluminescence flow biosensor for the determination of oxalate. Chem. J. Chin. Univ. 22:2001;215-217.
    • (2001) Chem. J. Chin. Univ. , vol.22 , pp. 215-217
    • Peng, Y.Y.1    Qin, W.2    Zhang, Z.J.3
  • 27
    • 77049145814 scopus 로고
    • Oxidation and reduction of glycolic and glycolic acid in plants
    • Zelitch I., Ochoa S. Oxidation and reduction of glycolic and glycolic acid in plants. J. Biol. Chem. 201:1953;707-709.
    • (1953) J. Biol. Chem. , vol.201 , pp. 707-709
    • Zelitch, I.1    Ochoa, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.