메뉴 건너뛰기




Volumn 45, Issue 3, 2005, Pages 412-417

Current of injury predicts adequate active lead fixation in permanent pacemaker/defibrillation leads

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CONTROLLED STUDY; DEFIBRILLATOR; ELECTROCARDIOGRAPHY; FEMALE; HEART ATRIUM; HEART INJURY; HEART VENTRICLE; HUMAN; IMPLANTATION; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; PARAMETER; PATIENT; PREDICTION; PRIORITY JOURNAL; ST SEGMENT ELEVATION; TIME;

EID: 13244299253     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jacc.2004.10.045     Document Type: Article
Times cited : (70)

References (8)
  • 1
    • 0017706910 scopus 로고
    • Comparison of unipolar and bipolar electrograms for cardiac pacemaker
    • V. DeCaprio, P. Hurzeler, S. Furman Comparison of unipolar and bipolar electrograms for cardiac pacemaker Circulation 56 1977 750 755
    • (1977) Circulation , vol.56 , pp. 750-755
    • Decaprio, V.1    Hurzeler, P.2    Furman, S.3
  • 3
    • 10144253063 scopus 로고
    • Sensing and timing the cardiac electrogram
    • D.L. Hayes 3rd edition Futura Publishing Company Mount Kisco, NY
    • S. Furman Sensing and timing the cardiac electrogram D.L. Hayes A Practice of Cardiac Pacing 3rd edition 1993 Futura Publishing Company Mount Kisco, NY 89 132
    • (1993) A Practice of Cardiac Pacing , pp. 89-132
    • Furman, S.1
  • 4
    • 0018645630 scopus 로고
    • Early malfunction of transvenous pacemaker electrodes: A three-center study
    • V. Parsonnet, M. Bilitch, S. Furman Early malfunction of transvenous pacemaker electrodes A three-center study Circulation 60 1979 590 596
    • (1979) Circulation , vol.60 , pp. 590-596
    • Parsonnet, V.1    Bilitch, M.2    Furman, S.3
  • 6
    • 0017626244 scopus 로고
    • Cardiac pacing and pacemakers III: Sensing the cardiac electrogram
    • S. Furman, P. Hurzeler, V. DeCaprio Cardiac pacing and pacemakers III Sensing the cardiac electrogram Am Heart J 93 1977 794 801
    • (1977) Am Heart J , vol.93 , pp. 794-801
    • Furman, S.1    Hurzeler, P.2    Decaprio, V.3
  • 7
    • 13244269280 scopus 로고    scopus 로고
    • Time-related improvement in pacing parameters after active fixation lead implantation: Insights gained from injury current analysis
    • N. Avramovitch, M. Kim, R. Trohman Time-related improvement in pacing parameters after active fixation lead implantation: insights gained from injury current analysis (abstr) Heart Rhythm 71 2004 219
    • (2004) Heart Rhythm , vol.71 , pp. 219
    • Avramovitch, N.1    Kim, M.2    Trohman, R.3
  • 8
    • 0025239841 scopus 로고
    • Acute changes in pacing threshold and R- or P-wave amplitude during permanent pacemaker implantation
    • M. De Buitleir, W. Kou, S. Schmaltz, F. Morady Acute changes in pacing threshold and R- or P-wave amplitude during permanent pacemaker implantation Am J Cardiol 65 1990 999 1003
    • (1990) Am J Cardiol , vol.65 , pp. 999-1003
    • De Buitleir, M.1    Kou, W.2    Schmaltz, S.3    Morady, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.