메뉴 건너뛰기




Volumn 41, Issue 12, 2004, Pages 1255-1270

A thermohydraulic code for low temperature nuclear heating reactor and its passive residual heat removal systems

Author keywords

Code; Low temperature nuclear heating reactor (LTNHR); Natural circulation; Passive residual heat removal system (PRHRS); Thermohydraulic

Indexed keywords

LOW TEMPERATURE NUCLEAR HEATING REACTOR (LTNHR); NATURAL CIRCULATION; PASSIVE RESIDUAL HEAT REMOVAL SYSTEM (PRHRS); THERMOHYDRAULIC SAFETY ANALYSIS CODES;

EID: 13244292339     PISSN: 00223131     EISSN: None     Source Type: Journal    
DOI: 10.1080/18811248.2004.9726355     Document Type: Article
Times cited : (3)

References (24)
  • 1
    • 13244252991 scopus 로고
    • Safety aspects of the 200MWth siemens nuclear district heating plant
    • G. Andreas, “Safety aspects of the 200MWth siemens nuclear district heating plant,” Nucl. Eng. Des., 131, 129-138 (1991).
    • (1991) Nucl. Eng. Des. , vol.131 , pp. 129-138
    • Andreas, G.1
  • 2
    • 0346541599 scopus 로고    scopus 로고
    • Nuclear district heat plants AST-500, present status and prospects for future in Russia
    • B. S. Oleg, V. K. Andrey, “Nuclear district heat plants AST-500, present status and prospects for future in Russia,” Nucl. Eng. Des., 173, 109-117 (1997).
    • (1997) Nucl. Eng. Des. , vol.173 , pp. 109-117
    • Oleg, B.S.1    Andrey, V.K.2
  • 3
    • 0346541595 scopus 로고    scopus 로고
    • Inherently safe pool-type reactor as a generator of low grade heat for district heating, air conditioning and salt water desalination
    • E. O. Adamov, Y. M. Cherkashov, A. A. Romenkov, et al., “Inherently safe pool-type reactor as a generator of low grade heat for district heating, air conditioning and salt water desalination,” Nucl. Eng. Des., 173, 167-174 (1997).
    • (1997) Nucl. Eng. Des. , vol.173 , pp. 167-174
    • Adamov, E.O.1    Cherkashov, Y.M.2    Romenkov, A.A.3
  • 4
    • 43949162690 scopus 로고
    • Technical design features and safety analysis of the 200 MWt nuclear heating reactor
    • D. Z. Wang, Z. Y. Gao, W. X. Zheng, “Technical design features and safety analysis of the 200 MWt nuclear heating reactor,” Nucl. Eng. Des., 143, 1-7 (1993).
    • (1993) Nucl. Eng. Des. , vol.143 , pp. 1-7
    • Wang, D.Z.1    Gao, Z.Y.2    Zheng, W.X.3
  • 5
    • 43949162963 scopus 로고
    • The design characteristics and construction experiences of the 5MWt nuclear heating reactor
    • D. Z. Wang, “The design characteristics and construction experiences of the 5MWt nuclear heating reactor,” Nucl. Eng. Des., 143, 19-24 (1993).
    • (1993) Nucl. Eng. Des. , vol.143 , pp. 19-24
    • Wang, D.Z.1
  • 7
    • 85010613187 scopus 로고    scopus 로고
    • Modeling and dynamic simulation for emergency residual heat removal system of AC-600 (In Chinese)
    • S. Z. Qiu, T. Zhou, Y. J. Guo, et al., “Modeling and dynamic simulation for emergency residual heat removal system of AC-600 (In Chinese),” Chinese Nucl. Power Eng., 20, 143-147 (1999).
    • (1999) Chinese Nucl. Power Eng. , vol.20 , pp. 143-147
    • Qiu, S.Z.1    Zhou, T.2    Guo, Y.J.3
  • 9
    • 0035414143 scopus 로고    scopus 로고
    • Theoretical study on density wave oscillation of two-phase natural circulation under low quality conditions
    • G. H. Su, D. N. Jia, K. Fukuda, Y. J. Guo, “Theoretical study on density wave oscillation of two-phase natural circulation under low quality conditions,” J. Nucl. Sci. Technol., 38[8], 607-613 (2001).
    • (2001) J. Nucl. Sci. Technol. , vol.38 , Issue.8 , pp. 607-613
    • Su, G.H.1    Jia, D.N.2    Fukuda, K.3    Guo, Y.J.4
  • 10
    • 0036603713 scopus 로고    scopus 로고
    • Theoretical and experimental study on density wave oscillation of two-phase natural circulation of low equilibrium quality
    • G. H. Su, D. N. Jia, K. Fukuda, Y. J. Guo, “Theoretical and experimental study on density wave oscillation of two-phase natural circulation of low equilibrium quality,” Nucl. Eng. Des., 215, 187-198 (2002).
    • (2002) Nucl. Eng. Des. , vol.215 , pp. 187-198
    • Su, G.H.1    Jia, D.N.2    Fukuda, K.3    Guo, Y.J.4
  • 14
    • 33750603506 scopus 로고    scopus 로고
    • Haerbin Industry University Press, [in Chinese]
    • Y. W. Ma, Design and Utility of Air Cooler, Haerbin Industry University Press, (1998), [in Chinese].
    • (1998) Design and Utility of Air Cooler
    • Ma, Y.W.1
  • 17
    • 13244263398 scopus 로고
    • Chinese Atomic Energy Press, Beijing, [in Chinese]
    • S. H. Du, Nuclear Power Station, Chinese Atomic Energy Press, Beijing, 85-86 (1992), [in Chinese].
    • (1992) Nuclear Power Station , pp. 85-86
    • Du, S.H.1
  • 22
    • 0033877924 scopus 로고    scopus 로고
    • Thermalhydraulic inverstigation using a test facility simulating 200 MW integral heating reactor
    • H. J. Jia, S. R. Wu, H. X. Li, et al., “Thermalhydraulic inverstigation using a test facility simulating 200 MW integral heating reactor,” J. Nucl. Sci. Technol., 37[2], 202-208 (2000).
    • (2000) J. Nucl. Sci. Technol. , vol.37 , Issue.2 , pp. 202-208
    • Jia, H.J.1    Wu, S.R.2    Li, H.X.3
  • 23
    • 0035358340 scopus 로고    scopus 로고
    • Review of thermalhy-draulic experimental researches at INET,'
    • H. J. Jia, S. Y. Jiang, Y. H. Xu, et al., “Review of thermalhy-draulic experimental researches at INET,'' J. Nucl. Sci. Tech-nol., 38[6], 453-460 (2001).
    • (2001) J. Nucl. Sci. Tech-Nol. , vol.38 , Issue.6 , pp. 453-460
    • Jia, H.J.1    Jiang, S.Y.2    Xu, Y.H.3
  • 24
    • 13244290571 scopus 로고    scopus 로고
    • Analysis about residual heat process in 200MW heated reactor
    • [in Chinese]
    • H. T. Shun, M. Z. Peng, “Analysis about residual heat process in 200MW heated reactor,” Chinese Nucl. Power Eng., 19[1], 21-25 (1998), [in Chinese].
    • (1998) Chinese Nucl. Power Eng. , vol.19 , Issue.1 , pp. 21-25
    • Shun, H.T.1    Peng, M.Z.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.