메뉴 건너뛰기




Volumn 26, Issue 1, 2005, Pages 49-60

A multi-centre study of dispensing methods and hand doses in uk hospital radiopharmacies

Author keywords

Hand dose; Radiopharmaceutical dispensing; Radiopharmaceutical preparation; Radiopharmacy

Indexed keywords

MOLYBDENUM 99; RADIOPHARMACEUTICAL AGENT; TECHNETIUM 99M;

EID: 13244272034     PISSN: 01433636     EISSN: 14735628     Source Type: Journal    
DOI: 10.1097/00006231-200501000-00009     Document Type: Article
Times cited : (20)

References (9)
  • 1
    • 85026145484 scopus 로고    scopus 로고
    • The Ionising Radiations Regulations. 1999 SI 1999/3232 London: Stationery Office.
    • The Ionising Radiations Regulations. 1999 SI 1999/3232 London: Stationery Office.
  • 2
    • 8544265433 scopus 로고
    • Radiation dose distribution to the hands of a radiopharmacist
    • Batchelor S, Baldock C, Webber D. Radiation dose distribution to the hands of a radiopharmacist. Pharm J Hosp Pharm 1991; 247(suppl):38-39.
    • (1991) Pharm J Hosp Pharm , vol.247 , pp. 38-39
    • Batchelor, S.1    Baldock, C.2    Webber, D.3
  • 3
    • 0034198858 scopus 로고    scopus 로고
    • A study of doses to the hands during dispensing of radiopharmaceuticals
    • Dhanse S, Martin CJ, Hilditch TE, Elliott AT. A study of doses to the hands during dispensing of radiopharmaceuticals. Nucl Med Commun 2000; 21:511-519.
    • (2000) Nucl Med Commun , vol.21 , pp. 511-519
    • Dhanse, S.1    Martin, C.J.2    Hilditch, T.E.3    Elliott, A.T.4
  • 4
    • 0025340652 scopus 로고
    • Fifteen years of radiological protection experience in a regional radiopharmacy
    • Hilditch TE, Elliott AT, Anstee DE. Fifteen years of radiological protection experience in a regional radiopharmacy. Health Phys 1990; 59:109-116.
    • (1990) Health Phys , vol.59 , pp. 109-116
    • Hilditch, T.E.1    Elliott, A.T.2    Anstee, D.E.3
  • 6
    • 0037356439 scopus 로고    scopus 로고
    • Investigation using AEGIS of options for shielding the hand during preparation and injection of radiopharmaceuticals
    • Whitby M, Martin CJ. Investigation using AEGIS of options for shielding the hand during preparation and injection of radiopharmaceuticals. J Radiol Prot 2003; 23:79-97.
    • (2003) J Radiol Prot , vol.23 , pp. 79-97
    • Whitby, M.1    Martin, C.J.2
  • 7
    • 0032893769 scopus 로고    scopus 로고
    • Reductions in finger doses for radiopharmaceutical dispensing afforded by a syringe shield and an automated dose dispenser
    • Montgomery A, Anstee DE, Martin CJ, Hilditch TE. Reductions in finger doses for radiopharmaceutical dispensing afforded by a syringe shield and an automated dose dispenser. Nucl Med Commun 1999; 20:189-194.
    • (1999) Nucl Med Commun , vol.20 , pp. 189-194
    • Montgomery, A.1    Anstee, D.E.2    Martin, C.J.3    Hilditch, T.E.4
  • 8
    • 85026142993 scopus 로고    scopus 로고
    • Martin CJ, Whitby M, Hilditch T, Anstee D. Use of an electronic finger dosemeter in optimisation of finger doses. In: Proc 6th European ALARA Madrid: Network Workshop. 2002, [online] pp. 149-158.
    • Martin CJ, Whitby M, Hilditch T, Anstee D. Use of an electronic finger dosemeter in optimisation of finger doses. In: Proc 6th European ALARA Madrid: Network Workshop. 2002, [online] pp. 149-158.
  • 9
    • 0030822845 scopus 로고    scopus 로고
    • Reduction of extremity dose in the radiopharmacy
    • McKenzie A. Reduction of extremity dose in the radiopharmacy. Nucl Med Commun 1997; 18:578-581.
    • (1997) Nucl Med Commun , vol.18 , pp. 578-581
    • McKenzie, A.1