메뉴 건너뛰기




Volumn 102, Issue 2, 2005, Pages 481-483

Use of the laryngeal Tube-S™ for airway management and prevention of aspiration after a failed tracheal intubation in a parturient [5]

Author keywords

[No Author keywords available]

Indexed keywords

SUXAMETHONIUM; THIOPENTAL;

EID: 13244251400     PISSN: 00033022     EISSN: None     Source Type: Journal    
DOI: 10.1097/00000542-200502000-00039     Document Type: Letter
Times cited : (18)

References (21)
  • 2
    • 0003307725 scopus 로고    scopus 로고
    • Difficult and failed intubation in obstetrics
    • Edited by Latto IP, Vaughan RS. London, WB Saunders
    • Harmer M: Difficult and failed intubation in obstetrics. Difficulties in Tracheal Intubation, 2nd edition. Edited by Latto IP, Vaughan RS. London, WB Saunders, 1997; pp 309-10
    • (1997) Difficulties in Tracheal Intubation, 2nd Edition , pp. 309-310
    • Harmer, M.1
  • 3
    • 0034754907 scopus 로고    scopus 로고
    • National survey of rapid sequence induction
    • Morris J, Cook TM: National survey of rapid sequence induction. Anaesthesia 2001; 56:1090-7
    • (2001) Anaesthesia , vol.56 , pp. 1090-1097
    • Morris, J.1    Cook, T.M.2
  • 4
    • 0031844409 scopus 로고    scopus 로고
    • Clinical pharmacokinetics of neuromuscular relaxants in pregnancy
    • Guay J, Grenier Y, Varin F: Clinical pharmacokinetics of neuromuscular relaxants in pregnancy. Clin Pharmacokinet 1998; 34:483
    • (1998) Clin Pharmacokinet , vol.34 , pp. 483
    • Guay, J.1    Grenier, Y.2    Varin, F.3
  • 6
    • 0346368289 scopus 로고
    • The laryngeal mask in failed intubation
    • DeMello WF, Konan M: The laryngeal mask in failed intubation [letter]. Anaesthesia 1991; 45:227-8
    • (1991) Anaesthesia , vol.45 , pp. 227-228
    • DeMello, W.F.1    Konan, M.2
  • 7
    • 0026566956 scopus 로고
    • Laryngeal mask for failed intubation in emergency caesarean section
    • Pricus V, Pricus L, Sorkor D: Laryngeal mask for failed intubation in emergency caesarean section. Can J Anaesth 1992; 39:893
    • (1992) Can J Anaesth , vol.39 , pp. 893
    • Pricus, V.1    Pricus, L.2    Sorkor, D.3
  • 8
    • 0026813943 scopus 로고
    • Laryngeal mask for failed intubation at caesarean section
    • Storey J: Laryngeal mask for failed intubation at caesarean section. Anaesth Intens Care 1992; 20:118-9
    • (1992) Anaesth Intens Care , vol.20 , pp. 118-119
    • Storey, J.1
  • 9
    • 0033939084 scopus 로고    scopus 로고
    • Failed tracheal intubation in obstetrics: A 6-year review in a UK hospital
    • Barnardo PD, Jenkins JG: Failed tracheal intubation in obstetrics: A 6-year review in a UK hospital. Anaesthesia 2000; 55:685-94
    • (2000) Anaesthesia , vol.55 , pp. 685-694
    • Barnardo, P.D.1    Jenkins, J.G.2
  • 10
    • 0034743737 scopus 로고    scopus 로고
    • Is it safe to artificially ventilate a paralyzed patient through the laryngeal mask? The injury is still out
    • Sideras G, Hunter JM: Is it safe to artificially ventilate a paralyzed patient through the laryngeal mask? The injury is still out. Br J Anaesth 2001; 86:749-53
    • (2001) Br J Anaesth , vol.86 , pp. 749-753
    • Sideras, G.1    Hunter, J.M.2
  • 11
    • 0348227668 scopus 로고    scopus 로고
    • Use of a ProSeal™ laryngeal mask airway for airway maintenance during emergency caesarean section after failed tracheal intubation
    • Awan R, Nolan JP, Cook TM: Use of a ProSeal™ laryngeal mask airway for airway maintenance during emergency caesarean section after failed tracheal intubation. Br J Anaesth 2004; 92:144-6
    • (2004) Br J Anaesth , vol.92 , pp. 144-146
    • Awan, R.1    Nolan, J.P.2    Cook, T.M.3
  • 12
    • 0036098954 scopus 로고    scopus 로고
    • Aspiration prevented by the ProSeal™ laryngeal mask airway: A case report
    • Evans NR, Llewellyn RL, Gardner SV, James MFM: Aspiration prevented by the ProSeal™ laryngeal mask airway: A case report. Can J Anaesth 2002; 49:413-6
    • (2002) Can J Anaesth , vol.49 , pp. 413-416
    • Evans, N.R.1    Llewellyn, R.L.2    Gardner, S.V.3    James, M.F.M.4
  • 13
    • 0037285949 scopus 로고    scopus 로고
    • Protection from aspiration with the LMA-ProSeal™ after vomiting: A case report
    • Mark DA: Protection from aspiration with the LMA-ProSeal™ after vomiting: A case report. Can J Anesth 2003; 50:78-80
    • (2003) Can J Anesth , vol.50 , pp. 78-80
    • Mark, D.A.1
  • 14
    • 0030880769 scopus 로고    scopus 로고
    • Prevention of tracheal aspiration in a patient with a high risk of regurgitation using a new double-lumen gastric laryngeal mask airway
    • Agro F, Brain A, Gabbrielli A, Alloni R, Pellegrino P, Cataldo R, Costamagna G, Carassiti M: Prevention of tracheal aspiration in a patient with a high risk of regurgitation using a new double-lumen gastric laryngeal mask airway. Gastrointest Endosc 1997; 46:257-8
    • (1997) Gastrointest Endosc , vol.46 , pp. 257-258
    • Agro, F.1    Brain, A.2    Gabbrielli, A.3    Alloni, R.4    Pellegrino, P.5    Cataldo, R.6    Costamagna, G.7    Carassiti, M.8
  • 15
    • 0030161634 scopus 로고    scopus 로고
    • Airway protection with the new laryngeal mask prototype
    • Brimacombe J: Airway protection with the new laryngeal mask prototype. Anaesthesia 1996; 51:602-3
    • (1996) Anaesthesia , vol.51 , pp. 602-603
    • Brimacombe, J.1
  • 18
    • 13244270446 scopus 로고    scopus 로고
    • Supraglottic airway devices with oesophageal access: Comparison of combitube, LMA proseal and LTS in a resuscitation model
    • Genzwürker HV, Finteis T, Krieter H, Ellinger K: Supraglottic airway devices with oesophageal access: Comparison of combitube, LMA proseal and LTS in a resuscitation model. Eur J Anaesth 2003; 20:171
    • (2003) Eur J Anaesth , vol.20 , pp. 171
    • Genzwürker, H.V.1    Finteis, T.2    Krieter, H.3    Ellinger, K.4
  • 19
    • 18244414462 scopus 로고    scopus 로고
    • First clinical experiences with the new LTS, a laryngeal tube with an esophageal drain
    • Genzwürker HV, Finteis T, Hinkelbein J, Ellinger K: First clinical experiences with the new LTS, a laryngeal tube with an esophageal drain. Anesthesist 2003; 52:697-702
    • (2003) Anesthesist , vol.52 , pp. 697-702
    • Genzwürker, H.V.1    Finteis, T.2    Hinkelbein, J.3    Ellinger, K.4
  • 21
    • 0036234840 scopus 로고    scopus 로고
    • The influence of cuff volume and anatomic location on pharyngeal, esophageal and tracheal mucosal pressure with the esophageal tracheal combitube
    • Keller C, Brimacombe J, Boehler M, Loeckinger A, Puehringer F: The influence of cuff volume and anatomic location on pharyngeal, esophageal and tracheal mucosal pressure with the esophageal tracheal combitube. ANESTHESIOLOGY 2002; 96:1074-7
    • (2002) Anesthesiology , vol.96 , pp. 1074-1077
    • Keller, C.1    Brimacombe, J.2    Boehler, M.3    Loeckinger, A.4    Puehringer, F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.