메뉴 건너뛰기




Volumn 4, Issue , 2004, Pages

Non-invasive monitoring of diaphragmatic timing by means of surface contact sensors: An experimental study in dogs

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; CONTROLLED STUDY; CORRELATION COEFFICIENT; DEVICE; DIAPHRAGM MOVEMENT; DOG; LUNG FUNCTION TEST; MONITORING; MUSCLE CONTRACTION; MUSCLE FUNCTION; MUSCLE LENGTH; NONHUMAN; PIEZOELECTRICITY; PRESSURE; RESPIRATORY AIRFLOW; SENSOR; SIGNAL PROCESSING; THORAX WALL; TIME;

EID: 13144307190     PISSN: 14712466     EISSN: None     Source Type: Journal    
DOI: 10.1186/1471-2466-4-8     Document Type: Article
Times cited : (7)

References (13)
  • 1
    • 0028028458 scopus 로고
    • Evaluation of three different techniques used to measure chest wall movements in children
    • Ross RI, Helms PJ: Evaluation of three different techniques used to measure chest wall movements in children. Eur Respir J 1994, 7:2073-76.
    • (1994) Eur. Respir. J. , vol.7 , pp. 2073-2076
    • Ross, R.I.1    Helms, P.J.2
  • 2
    • 0015384501 scopus 로고
    • Changes in tidal volume, frequency and ventilation induced by their measurement
    • Gilbert R, Auchincloss JH, Brodsky J, Boden W: Changes in tidal volume, frequency and ventilation induced by their measurement. J Appl Physiol 1972, 33:252-254.
    • (1972) J. Appl. Physiol. , vol.33 , pp. 252-254
    • Gilbert, R.1    Auchincloss, J.H.2    Brodsky, J.3    Boden, W.4
  • 5
    • 1542284753 scopus 로고
    • Non invasive respiratory monitoring of diaphragm muscle with surface accelerometers. Animal model (Dogs)
    • Fiz JA, Comptois N, Salazkin I, Galdiz B, Morera J, Grassino AE: Non invasive respiratory monitoring of diaphragm muscle with surface accelerometers. Animal model (Dogs). Europ Resp J 1995, 8(19):1014.
    • (1995) Eur. Resp. J. , vol.8 , Issue.19 , pp. 1014
    • Fiz, J.A.1    Comptois, N.2    Salazkin, I.3    Galdiz, B.4    Morera, J.5    Grassino, A.E.6
  • 9
    • 33644485934 scopus 로고
    • Improved technique for estimating pleural pressure from esophageal ballons
    • Milic-Emili J, Turner JM, Galuser EM: Improved technique for estimating pleural pressure from esophageal ballons. J Appl Physiol 1964, 19:207-211.
    • (1964) J. Appl. Physiol. , vol.19 , pp. 207-211
    • Milic-Emili, J.1    Turner, J.M.2    Galuser, E.M.3
  • 10
    • 0030053687 scopus 로고    scopus 로고
    • Effects of diaphragm shortening on the mean action potential conduction velocity in canines
    • Sinderby C, Lindström L, Comtois N, Grassino AE: Effects of diaphragm shortening on the mean action potential conduction velocity in canines. J Physiol 1996, 490.1:207-214.
    • (1996) J. Physiol. , vol.490 , Issue.1 , pp. 207-214
    • Sinderby, C.1    Lindström, L.2    Comtois, N.3    Grassino, A.E.4
  • 12
    • 84908219488 scopus 로고
    • Statistical methods fot assessing agrrement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods fot assessing agrrement between two methods of clinical measurement. Lancet 1986, I:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 0026527803 scopus 로고
    • Vector analysis in partitioning of inspiratory muscle action in dogs
    • Ward ME, Paiva M, Macklem PT: Vector analysis in partitioning of inspiratory muscle action in dogs. Eur respir J 1992, 5:219-227.
    • (1992) Eur. Respir. J. , vol.5 , pp. 219-227
    • Ward, M.E.1    Paiva, M.2    Macklem, P.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.