메뉴 건너뛰기




Volumn 38, Issue 1, 2005, Pages 111-132

Potentiometric flow injection analysis of drotaverine hydrochloride in pharmaceutical preparations

Author keywords

Drotaverine hydrochloride; Flow injection analysis; Ion exchanger; Ion selective electrode; PVC membrane; Urine

Indexed keywords

AMINO ACID; CATION; DROTAVERINE; MOLYBDIC ACID; PHOSPHOTUNGSTIC ACID; PHTHALIC ACID DIBUTYL ESTER; PLASTICIZER; POLYVINYLCHLORIDE; SUGAR; TETRAPHENYLBORON;

EID: 13144281711     PISSN: 00032719     EISSN: None     Source Type: Journal    
DOI: 10.1081/AL-200043465     Document Type: Article
Times cited : (20)

References (34)
  • 1
    • 0035124042 scopus 로고    scopus 로고
    • Flow Injection Potentiometric Determination of Pipazethate Hydrochloride
    • Abdel-Ghani, N.T., Shoukry, A.F., and El-Nashar, R.M. 2001. Flow Injection Potentiometric Determination of Pipazethate Hydrochloride. Analyst, 126: 79-85.
    • (2001) Analyst , vol.126 , pp. 79-85
    • Abdel-Ghani, N.T.1    Shoukry, A.F.2    El-Nashar, R.M.3
  • 2
    • 0034080040 scopus 로고    scopus 로고
    • Salbutamol Plastic Membrane Electrodes Based on Individual and Mixed Ion-Exchangers of Salbutamolium Phosphotungstate and Phosphomolybdate
    • Abdel-Ghani, N.T., Rizk, M.S., and El-Nashar, R.M. 2000. Salbutamol Plastic Membrane Electrodes Based on Individual and Mixed Ion-Exchangers of Salbutamolium Phosphotungstate and Phosphomolybdate. Analyst, 125: 1129-1133.
    • (2000) Analyst , vol.125 , pp. 1129-1133
    • Abdel-Ghani, N.T.1    Rizk, M.S.2    El-Nashar, R.M.3
  • 3
    • 0001309716 scopus 로고
    • Trace Fluoride Determination with Specific Ion Electrode
    • Baumann, E. 1968. Trace Fluoride Determination with Specific Ion Electrode. Anal. Chim. Acta, 42: 127-132.
    • (1968) Anal. Chim. Acta , vol.42 , pp. 127-132
    • Baumann, E.1
  • 4
    • 0027332409 scopus 로고
    • High-Performance Liquid-Chromatographic Method for the Determination of Drotaverine in Human Plasma and Urine
    • Bolaji, O.O., Onyeji, C.O., Ogungbamila, F.O., Ogunbona, F.A. and Ogunlana, E.O. 1993. High-Performance Liquid-Chromatographic Method for the Determination of Drotaverine in Human Plasma and Urine. J. Chromatogr., 622: 93-97.
    • (1993) J. Chromatogr. , vol.622 , pp. 93-97
    • Bolaji, O.O.1    Onyeji, C.O.2    Ogungbamila, F.O.3    Ogunbona, F.A.4    Ogunlana, E.O.5
  • 5
    • 84930167786 scopus 로고
    • Recommendations for Nomenclature of Ion-Sensitive Electrodes (IUPAC Recommendations 1994)
    • Buck, R.P. and Lindner, E. 1994. Recommendations for Nomenclature of Ion-Sensitive Electrodes (IUPAC Recommendations 1994). Pure Appl. Chem., 66: 2527-2536.
    • (1994) Pure Appl. Chem. , vol.66 , pp. 2527-2536
    • Buck, R.P.1    Lindner, E.2
  • 6
    • 33847804944 scopus 로고
    • PVC Matrix Membrane Ion-Selective Electrodes Construction and Laboratory Experiments
    • Craggs, A., Moody, G.J., and Thomas, J.D.R. 1974. PVC Matrix Membrane Ion-Selective Electrodes Construction and Laboratory Experiments. J. Chem. Educ., 51: 541-547.
    • (1974) J. Chem. Educ. , vol.51 , pp. 541-547
    • Craggs, A.1    Moody, G.J.2    Thomas, J.D.R.3
  • 7
    • 0034108368 scopus 로고    scopus 로고
    • Selective Differential Spectrophotometric Methods for Determination of Niclosamide and Drotaverine Hydrochloride
    • Daabees, H.G. 2000. Selective Differential Spectrophotometric Methods for Determination of Niclosamide and Drotaverine Hydrochloride. Anal. Lett., 23: 639-656.
    • (2000) Anal. Lett. , vol.23 , pp. 639-656
    • Daabees, H.G.1
  • 8
    • 84988057773 scopus 로고
    • A Flow Injection/x-ray Photoelectron Spectroscopy Investigation of the Effect of Redox Equilibria on the Selectivity of an lodoide-Selective Electrode
    • Davey, D.E., Mulcahy, D.E., O'Connel, G.R., and Smart, R.S.C. 1995. A Flow Injection/x-ray Photoelectron Spectroscopy Investigation of the Effect of Redox Equilibria on the Selectivity of an lodoide-Selective Electrode. Electroanalysis, 7: 461-470.
    • (1995) Electroanalysis , vol.7 , pp. 461-470
    • Davey, D.E.1    Mulcahy, D.E.2    O'Connel, G.R.3    Smart, R.S.C.4
  • 9
    • 12444261319 scopus 로고    scopus 로고
    • + -Selective Potentiometric Sensor in Steady State and Transient Hydrodynamic Conditions
    • + -Selective Potentiometric Sensor in Steady State and Transient Hydrodynamic Conditions. Sensors and Actuators B, 91: 67-75.
    • (2003) Sensors and Actuators B , vol.91 , pp. 67-75
    • Dorneanu, S.A.1    Popescu, I.C.2    Fabry, P.3
  • 10
    • 0343226324 scopus 로고
    • Electrochemical Investigation of Drotaverine. I. Square-Wave Polarographic Measurement
    • Fulop, M., Kaloy, K., and Toth, A. 1986. Electrochemical Investigation of Drotaverine. I. Square-Wave Polarographic Measurement. Magy. Kem. Foly., 92: 468-473.
    • (1986) Magy. Kem. Foly. , vol.92 , pp. 468-473
    • Fulop, M.1    Kaloy, K.2    Toth, A.3
  • 12
    • 0023697047 scopus 로고
    • Computer-Aided Spectrophotometric of Multi-Component Drugs
    • Geher, J. and Szabo, E. 1988. Computer-Aided Spectrophotometric of Multi-Component Drugs. J. Pharm. Biomed. Anal., 6: 757-764.
    • (1988) J. Pharm. Biomed. Anal. , vol.6 , pp. 757-764
    • Geher, J.1    Szabo, E.2
  • 13
    • 0027158647 scopus 로고
    • Ion-Pair Reversed-Phase Liquid-Chromatographic Identification and Quantitation of Papaverine Congeners
    • Girgis, E.H. 1993. Ion-Pair Reversed-Phase Liquid-Chromatographic Identification and Quantitation of Papaverine Congeners. J. Pharm. Sci., 82: 503-505.
    • (1993) J. Pharm. Sci. , vol.82 , pp. 503-505
    • Girgis, E.H.1
  • 15
    • 0041473772 scopus 로고
    • Determination of Phosphorus and Tungsten in Heteropoly Acids by EDTA-Titration
    • Hayashi, H. and Moffat, J.B. 1982. Determination of Phosphorus and Tungsten in Heteropoly Acids by EDTA-Titration. Talanta, 29: 943-945.
    • (1982) Talanta , vol.29 , pp. 943-945
    • Hayashi, H.1    Moffat, J.B.2
  • 16
    • 0019602573 scopus 로고
    • Model for Treatment of Selectivity Coefficients for Solid-State Ion-Selective Electrodes
    • Hulanicki, A. and Lewenstam, A. 1981. Model for Treatment of Selectivity Coefficients for Solid-State Ion-Selective Electrodes. Anal. Chem., 53: 1401-1405.
    • (1981) Anal. Chem. , vol.53 , pp. 1401-1405
    • Hulanicki, A.1    Lewenstam, A.2
  • 17
    • 0343661955 scopus 로고
    • Application of Differential Spectrophotometry to Determination of No-Spa [Drotaverine] in Biological Materials
    • Knaub, V.A. and Kartashov, V.A. 1989. Application of Differential Spectrophotometry to Determination of No-Spa [Drotaverine] in Biological Materials. Farmatsiya (Moscow), 38: 46-49.
    • (1989) Farmatsiya (Moscow) , vol.38 , pp. 46-49
    • Knaub, V.A.1    Kartashov, V.A.2
  • 18
    • 0027197218 scopus 로고
    • Modified High-Performance Liquid Chromatographic Method for Analysis of Drotaverine in Human Plasma
    • Lalla, J.K., Shah, M.U., Jain, M.B., and Sharma, A.H. 1993. Modified High-Performance Liquid Chromatographic Method for Analysis of Drotaverine in Human Plasma. J. Pharm. Biomed. Anal., 11: 385-388.
    • (1993) J. Pharm. Biomed. Anal. , vol.11 , pp. 385-388
    • Lalla, J.K.1    Shah, M.U.2    Jain, M.B.3    Sharma, A.H.4
  • 21
    • 0021123739 scopus 로고
    • A New Method for High-Performance Liquid Chromatographic Determination of Drotaverine in Plasma
    • Mezel, J., Kuttel, S., Szentmiklosi, P., Marton, S., and Racz, I. 1984. A New Method for High-Performance Liquid Chromatographic Determination of Drotaverine in Plasma. J. Pharm. Sci., 73: 1489-1491.
    • (1984) J. Pharm. Sci. , vol.73 , pp. 1489-1491
    • Mezel, J.1    Kuttel, S.2    Szentmiklosi, P.3    Marton, S.4    Racz, I.5
  • 22
    • 0000565793 scopus 로고
    • Theoretical Treatment of the Dynamic Response of Ion-Selective Membrane Electrodes
    • Morf, W.E., Linder, E., and Simon, W. 1975. Theoretical Treatment of the Dynamic Response of Ion-Selective Membrane Electrodes. Anal. Chem., 47: 1596-1601.
    • (1975) Anal. Chem. , vol.47 , pp. 1596-1601
    • Morf, W.E.1    Linder, E.2    Simon, W.3
  • 23
    • 0022885504 scopus 로고
    • Ion-Selective Membrane Electrodes for Clinical Use
    • Oesch, V., Ammann, D., and Simon, W. 1986. Ion-Selective Membrane Electrodes for Clinical Use. Clin Chem., 32: 1448-1459.
    • (1986) Clin. Chem. , vol.32 , pp. 1448-1459
    • Oesch, V.1    Ammann, D.2    Simon, W.3
  • 24
    • 37049115296 scopus 로고
    • Ion-Selective Membrane Electrodes
    • Pungor, E. and Toth, K. 1970. Ion-Selective Membrane Electrodes. A Review. Analyst, 95: 625-648.
    • (1970) Analyst , vol.95 , pp. 625-648
    • Pungor, E.1    Toth, K.2
  • 25
    • 0034787624 scopus 로고    scopus 로고
    • Construction and Performance Characteristics of Terbutaline Plastic Membrane Electrode in Batch and FIA Conditions
    • Rizk, M.S., Abdel-Ghani, N.T., and El Nashar, R.M. 2001. Construction and Performance Characteristics of Terbutaline Plastic Membrane Electrode in Batch and FIA Conditions. Microchem. J., 70: 93-101.
    • (2001) Microchem. J. , vol.70 , pp. 93-101
    • Rizk, M.S.1    Abdel-Ghani, N.T.2    El Nashar, R.M.3
  • 26
    • 85013558450 scopus 로고
    • Potentiometric Titration of Thallium (I) with Sodium Tetraphenylborate, Using Ion Selective Electrodes
    • Selig, W. 1980. Potentiometric Titration of Thallium (I) with Sodium Tetraphenylborate, Using Ion Selective Electrodes. Talanta, 27: 914-916.
    • (1980) Talanta , vol.27 , pp. 914-916
    • Selig, W.1
  • 27
    • 0018643538 scopus 로고
    • The intestinal absorption and excretion of 14C Drotaverine in Rats
    • Simon, G., Vargay, Z., Winter, M., and Szuts, T. 1979. The intestinal absorption and excretion of 14C Drotaverine In Rats. Eur. J. Drug Metab. Pharmacokinet., 4(4): 213-217.
    • (1979) Eur. J. Drug Metab. Pharmacokinet. , vol.4 , Issue.4 , pp. 213-217
    • Simon, G.1    Vargay, Z.2    Winter, M.3    Szuts, T.4
  • 28
    • 0342285898 scopus 로고
    • Determination of Aqueous Phosphate by Ascorbic Acid Reduction of Phosphomolybdic Acid
    • Towns, T.G. 1986. Determination of Aqueous Phosphate by Ascorbic Acid Reduction of Phosphomolybdic Acid. Anal. Chem., 58: 223-229.
    • (1986) Anal. Chem. , vol.58 , pp. 223-229
    • Towns, T.G.1
  • 29
    • 0002128064 scopus 로고
    • Potentiometric Flow-Injection Determination of Chloride
    • Trojanowicz, M. and Matuszewski, W. 1983. Potentiometric Flow-Injection Determination of Chloride. Anal. Chim. Acta, 151: 77-84.
    • (1983) Anal. Chim. Acta , vol.151 , pp. 77-84
    • Trojanowicz, M.1    Matuszewski, W.2
  • 30
    • 0034583224 scopus 로고    scopus 로고
    • Potentiometric Selectivity Coefficients of Ion-Selective Electrodes. Part I. Inorganic Cations (Technical Report)
    • Umezawa, Y., Buhlmann, P., Umezawa. K., Tohda, K., and Amemiya, S. 2000. Potentiometric Selectivity Coefficients of Ion-Selective Electrodes. Part I. Inorganic Cations (Technical Report). Pure Appl. Chem., 72: 1851-2082.
    • (2000) Pure Appl. Chem. , vol.72 , pp. 1851-2082
    • Umezawa, Y.1    Buhlmann, P.2    Umezawa, K.3    Tohda, K.4    Amemiya, S.5
  • 31
    • 0037784479 scopus 로고
    • Selectivity Coefficients for Ion-Selective Electrodes; Recommended Methods for Reporting k(pot,a,b) Values (IUPAC Technical Report)
    • Umezawa, Y., Umezawa, K., and Sato, H. 1995. Selectivity Coefficients for Ion-Selective Electrodes; Recommended Methods for Reporting k(pot,a,b) Values (IUPAC Technical Report). Pure Appl. Chem., 67: 507-518.
    • (1995) Pure Appl. Chem. , vol.67 , pp. 507-518
    • Umezawa, Y.1    Umezawa, K.2    Sato, H.3
  • 33
    • 0018900684 scopus 로고
    • Qualitative and Quantitative Determination of Drotaverine Metabolites in Rat Bile
    • Vargay, Z., Simon, G., Winter, M., and Szuts, T. 1980. Qualitative And Quantitative Determination of Drotaverine Metabolites In Rat Bile. Eur. J. Drug Metab. Pharmacokinet., 5 (2): 69-74.
    • (1980) Eur. J. Drug Metab. Pharmacokinet. , vol.5 , Issue.2 , pp. 69-74
    • Vargay, Z.1    Simon, G.2    Winter, M.3    Szuts, T.4
  • 34
    • 0000644872 scopus 로고    scopus 로고
    • Lead-Selective Membrane Electrode Based on Dithiophene Diazacrown Ether Derivatives
    • Yang, X.H., Kumar, N.H., Hibbert, D.B., Hua, C., and Alexander, P.W. 1997. Lead-Selective Membrane Electrode Based on Dithiophene Diazacrown Ether Derivatives. Electroanalysis, 9: 549-553.
    • (1997) Electroanalysis , vol.9 , pp. 549-553
    • Yang, X.H.1    Kumar, N.H.2    Hibbert, D.B.3    Hua, C.4    Alexander, P.W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.