메뉴 건너뛰기




Volumn 14, Issue 8, 1999, Pages 945-951

Design and application of combined hip-knee intramedullary joint replacements

Author keywords

Combination hip knee total joint; Finite element analysis; Hip arthroplasty; Knee arthroplasty; Massive prostheses

Indexed keywords

ADULT; ARTICLE; BIOMECHANICS; CASE REPORT; CLINICAL FEATURE; COMPUTER AIDED DESIGN; FEMALE; FEMUR FRACTURE; HIP ARTHROPLASTY; HIP PROSTHESIS; HUMAN; IMPLANTATION; KNEE ARTHROPLASTY; KNEE PROSTHESIS; MALE; MECHANICAL STRESS; RADIODIAGNOSIS; SURGICAL EQUIPMENT; SURGICAL TECHNIQUE; WEIGHT BEARING;

EID: 12944301120     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(99)90008-6     Document Type: Article
Times cited : (22)

References (10)
  • 1
    • 0025860449 scopus 로고
    • Revision of failed knee replacements using fixed axis hinges
    • Inglis AE, Walker PS: Revision of failed knee replacements using fixed axis hinges. J Bone Joint Surg Br 73:757, 1991
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 757
    • Inglis, A.E.1    Walker, P.S.2
  • 2
    • 0019990885 scopus 로고
    • Proximal femoral fractures following total hip arthroplasty
    • Bethea JS, DeAndrade JR, Fleming LL, et al: Proximal femoral fractures following total hip arthroplasty. Clin Orthop 170:95, 1982
    • (1982) Clin Orthop , vol.170 , pp. 95
    • Bethea, J.S.1    Deandrade, J.R.2    Fleming, L.L.3
  • 4
    • 0031239959 scopus 로고    scopus 로고
    • Internal forces and moments in the femur during walking
    • Duda GN, Schneider E, Chao EYS: Internal forces and moments in the femur during walking. J Biomech 30:933, 1997
    • (1997) J Biomech , vol.30 , pp. 933
    • Duda, G.N.1    Schneider, E.2    Chao, E.Y.S.3
  • 5
    • 0009483402 scopus 로고    scopus 로고
    • The forces in the distal femur and knee during different activities measured by telemetry
    • Taylor SJ, Walker PS, Perry J, et al: The forces in the distal femur and knee during different activities measured by telemetry. Trans Orthop Res Soc 22:259, 1997
    • (1997) Trans Orthop Res Soc , vol.22 , pp. 259
    • Taylor, S.J.1    Walker, P.S.2    Perry, J.3
  • 6
    • 0031838760 scopus 로고    scopus 로고
    • The forces in the distal femur and the knee during walking and other activities measured by telemetry
    • Taylor SJ, Walker PS, Perry J, et al: The forces in the distal femur and the knee during walking and other activities measured by telemetry. J Arthroplasty 13: 428, 1998
    • (1998) J Arthroplasty , vol.13 , pp. 428
    • Taylor, S.J.1    Walker, P.S.2    Perry, J.3
  • 7
    • 0024000434 scopus 로고
    • Fatigue properties of acrylic bone cements: Review of the literature
    • Krause W, Mathis RS: Fatigue properties of acrylic bone cements: review of the literature. J Biomed Mater Res 22(suppl A1):37, 1988
    • (1988) J Biomed Mater Res , vol.22 , Issue.SUPPL. A1 , pp. 37
    • Krause, W.1    Mathis, R.S.2
  • 8
    • 0018096055 scopus 로고
    • Some clinically relevant variables affecting the mechanical behaviour of bone cement
    • Lee AJC, Ling RSM, Vangala SS: Some clinically relevant variables affecting the mechanical behaviour of bone cement. Arch Orthop Traumat Surg 92:1, 1978
    • (1978) Arch Orthop Traumat Surg , vol.92 , pp. 1
    • Lee, A.J.C.1    Ling, R.S.M.2    Vangala, S.S.3
  • 9
    • 12944332455 scopus 로고
    • Time dependent mechanical properties of normal and carbon fiber reinforced bone cement
    • Saha S, Pal S, Albright JA: Time dependent mechanical properties of normal and carbon fiber reinforced bone cement. Trans Orthop Res Soc 6:296, 1981
    • (1981) Trans Orthop Res Soc , vol.6 , pp. 296
    • Saha, S.1    Pal, S.2    Albright, J.A.3
  • 10
    • 85031641273 scopus 로고    scopus 로고
    • Brochure. IMI Titanium Ltd, Birmingham, UK
    • Brochure. IMI Titanium Ltd, Birmingham, UK


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.