메뉴 건너뛰기




Volumn 45, Issue 5, 1999, Pages 471-477

Progress of an electrohydraulic total artificial heart system with a separate energy converter

Author keywords

[No Author keywords available]

Indexed keywords

LITHIUM ION;

EID: 12944265463     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002480-199909000-00020     Document Type: Article
Times cited : (10)

References (10)
  • 1
    • 0027454370 scopus 로고
    • In vivo testing of a completely implantable total artificial heart system
    • Snyder AJ, Rosenberg G, Weiss WJ, et al: In vivo testing of a completely implantable total artificial heart system. ASAIO J 39: M177-M184, 1993.
    • (1993) ASAIO J , vol.39
    • Snyder, A.J.1    Rosenberg, G.2    Weiss, W.J.3
  • 2
    • 0343650607 scopus 로고
    • Development of an implantable total artificial heart: Initial animal experiments
    • Akutsu T, Koyanagi H (eds), Tokyo, Springer-Verlag
    • Harasaki H, Fukumachi K, Massiello A, et al: Development of an implantable total artificial heart: initial animal experiments, in Akutsu T, Koyanagi H (eds), Heart Replacement: Artificial Heart, Volume 4.Tokyo, Springer-Verlag, 1993, pp.173-179.
    • (1993) Heart Replacement: Artificial Heart , vol.4 , pp. 173-179
    • Harasaki, H.1    Fukumachi, K.2    Massiello, A.3
  • 4
    • 0027377874 scopus 로고
    • In vivo long-term evaluation of the Utah electrohydraulic total artificial heart
    • Tatsumi E, Khanwilkar PS, Rowles JR, ef al: In vivo long-term evaluation of the Utah electrohydraulic total artificial heart. ASAIO J 39: M373-M380, 1993.
    • (1993) ASAIO J , vol.39
    • Tatsumi, E.1    Khanwilkar, P.S.2    Rowles, J.R.3
  • 5
    • 0025457785 scopus 로고
    • An electrohydraulic total artificial heart with a separately placed actuator
    • Taenaka Y, Sekii H, Tatsumi E, et al: An electrohydraulic total artificial heart with a separately placed actuator. Trans ASAIO 36: M242-M245, 1990.
    • (1990) Trans ASAIO , vol.36
    • Taenaka, Y.1    Sekii, H.2    Tatsumi, E.3
  • 6
    • 85135705031 scopus 로고
    • Performance of the periphery pump
    • Iversen HW: Performance of the periphery pump. Trans Am Soc Mechan Eng 77: 19-28, 1955.
    • (1955) Trans Am Soc Mechan Eng , vol.77 , pp. 19-28
    • Iversen, H.W.1
  • 7
    • 85135751530 scopus 로고
    • A theory of the fluid-dynamic mechanism of regenerative pumps
    • Wilson WA, Santalo MA: A theory of the fluid-dynamic mechanism of regenerative pumps. Trans Am Soc Mechan Eng 77: 1303-1316, 1955.
    • (1955) Trans Am Soc Mechan Eng , vol.77 , pp. 1303-1316
    • Wilson, W.A.1    Santalo, M.A.2
  • 8
    • 10244260616 scopus 로고
    • Research on the characteristics of regenerative pump
    • Shimosaka M, Yamazaki S: Research on the characteristics of regenerative pump. Trans Soc Mechan Eng Japan 25: 943-950, 1959.
    • (1959) Trans Soc Mechan Eng Japan , vol.25 , pp. 943-950
    • Shimosaka, M.1    Yamazaki, S.2
  • 9
    • 18144441792 scopus 로고    scopus 로고
    • In vitro and in vivo evaluation of a left-right balancing capacity of an interatrial shunt in an electrohydraulic total artificial heart system
    • Tatsumi E, Nakamura M, Masuzawa T, ef al: In vitro and in vivo evaluation of a left-right balancing capacity of an interatrial shunt in an electrohydraulic total artificial heart system. ASAIO J 43: M619-M625, 1997.
    • (1997) ASAIO J , vol.43
    • Tatsumi, E.1    Nakamura, M.2    Masuzawa, T.3
  • 10
    • 18144445205 scopus 로고    scopus 로고
    • In vitro and in vivo heat dissipation of an electrohydraulic totally implantable artificial heart
    • Endo S, Masuzawa T, Tatsumi E, et al: In vitro and in vivo heat dissipation of an electrohydraulic totally implantable artificial heart. ASAIO J 43: M592-M597, 1997.
    • (1997) ASAIO J , vol.43
    • Endo, S.1    Masuzawa, T.2    Tatsumi, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.