-
1
-
-
0030926834
-
Use of motor current in flow rate measurement for the magnetically suspended centrifugal blood pump
-
T. Tsukiya, T. Akamatsu, K. Nishimura, T. Yamada, and T. Nakazeki. Use of motor current in flow rate measurement for the magnetically suspended centrifugal blood pump. Artificial Organs, Vol. 21, No. 5, pp. 396-401, 1997.
-
(1997)
Artificial Organs
, vol.21
, Issue.5
, pp. 396-401
-
-
Tsukiya, T.1
Akamatsu, T.2
Nishimura, K.3
Yamada, T.4
Nakazeki, T.5
-
2
-
-
0036430056
-
Flow rate and pressure head estimation in a centrifugal blood pump
-
A. Funakubo, S. Ahmed, I. Sakuma, and Y. Fukui. Flow rate and pressure head estimation in a centrifugal blood pump. Artificial Organ, Vol. 26, No. 11, pp. 985-990, 2002.
-
(2002)
Artificial Organ
, vol.26
, Issue.11
, pp. 985-990
-
-
Funakubo, A.1
Ahmed, S.2
Sakuma, I.3
Fukui, Y.4
-
3
-
-
0033848910
-
Physical model-based indirect measurements of blood pressure and flow using a centrifugal pump
-
T. Kitamura, Y. Matsushima, T. Tokuyama, S. Kono, K. Nishimura, M. Komeda, M. Yanai, T. Kijima, and C. Nojiri. Physical model-based indirect measurements of blood pressure and flow using a centrifugal pump. Artificial Organ, Vol. 24, No. 8, pp. 589-593, 2000.
-
(2000)
Artificial Organ
, vol.24
, Issue.8
, pp. 589-593
-
-
Kitamura, T.1
Matsushima, Y.2
Tokuyama, T.3
Kono, S.4
Nishimura, K.5
Komeda, M.6
Yanai, M.7
Kijima, T.8
Nojiri, C.9
-
4
-
-
0036630618
-
Sensorless estimation of pressure head and flow of a continuous flow artificial heart based on input power and rotational speed
-
M. Yoshizawa, T. Sato, A. Tanaka, K. Abe, H. Takeda, T. Yambe, S. Nitta, and Y. Nose. Sensorless estimation of pressure head and flow of a continuous flow artificial heart based on input power and rotational speed. ASAIO J., Vol. 48, No. 4, pp. 443-448, 2002.
-
(2002)
ASAIO J.
, vol.48
, Issue.4
, pp. 443-448
-
-
Yoshizawa, M.1
Sato, T.2
Tanaka, A.3
Abe, K.4
Takeda, H.5
Yambe, T.6
Nitta, S.7
Nose, Y.8
-
5
-
-
0031902721
-
Development of a flow estimation and control system of an implantable centrifugal blood pump for circulatory assist
-
Y. Wakisaka, Y. Okuzono, Y. Taenaka, K. Chikanari, S. Endo, T. Masuzawa, and H. Takano. Development of a flow estimation and control system of an implantable centrifugal blood pump for circulatory assist. Artificial Organ, Vol. 22, No. 6, pp. 488-492, 1998.
-
(1998)
Artificial Organ
, vol.22
, Issue.6
, pp. 488-492
-
-
Wakisaka, Y.1
Okuzono, Y.2
Taenaka, Y.3
Chikanari, K.4
Endo, S.5
Masuzawa, T.6
Takano, H.7
-
6
-
-
0035168270
-
Application of indirect flow rate measurement using motor driving signals to a centrifugal blood pump with an integrated motor
-
T. Tsukiya, Y. Taenaka, T. Nishinaka, M. Oshikawa, H. Ohnishi, E. Tatsumi, H. Takano, Y. Konishi, K. Ito, and M. Shimada. Application of indirect flow rate measurement using motor driving signals to a centrifugal blood pump with an integrated motor. Artificial Organs, Vol. 25, No. 9, pp. 692-696, 2001.
-
(2001)
Artificial Organs
, vol.25
, Issue.9
, pp. 692-696
-
-
Tsukiya, T.1
Taenaka, Y.2
Nishinaka, T.3
Oshikawa, M.4
Ohnishi, H.5
Tatsumi, E.6
Takano, H.7
Konishi, Y.8
Ito, K.9
Shimada, M.10
-
7
-
-
12244251401
-
In vivo test of pressure head and flow rate estimation in a continuous-flow artificial heart
-
A. Tanaka, M. Yoshizawa, K. Abe, H. Takeda, T. Yambe, and S. Nitta. In vivo test of pressure head and flow rate estimation in a continuous-flow artificial heart. Artificial Organ, Vol. 27, No. 1, pp. 99-103, 2003.
-
(2003)
Artificial Organ
, vol.27
, Issue.1
, pp. 99-103
-
-
Tanaka, A.1
Yoshizawa, M.2
Abe, K.3
Takeda, H.4
Yambe, T.5
Nitta, S.6
|