메뉴 건너뛰기




Volumn 22, Issue SUPPL. 2, 2004, Pages 60-66

New trends in HDF therapies: Validity of internal filtration-enhanced hemodialysis

Author keywords

Fiber, density ratio; Fiber, effective length; Fiber, inner diameter; Internal filtration enhanced hemodialysis; Solute clearance

Indexed keywords

ENDOTOXIN;

EID: 12544254813     PISSN: 02535068     EISSN: None     Source Type: Journal    
DOI: 10.1159/000081877     Document Type: Conference Paper
Times cited : (7)

References (8)
  • 1
    • 0023709458 scopus 로고
    • Clinical experience with a new hemodiafiltration system
    • Rindi P, Pilone N, Ricco V, Cioni L: Clinical experience with a new hemodiafiltration system. ASAIO Trans 1988;34:765-768.
    • (1988) ASAIO Trans , vol.34 , pp. 765-768
    • Rindi, P.1    Pilone, N.2    Ricco, V.3    Cioni, L.4
  • 4
    • 0029880481 scopus 로고    scopus 로고
    • Evaluation of a new dialyzer that can substitute much fluid - Plug dialyzer
    • Hosoya N, Sasaki M, Takesawa S: Evaluation of a new dialyzer that can substitute much fluid - plug dialyzer (in Japanese). Jpn J Artif Organs 1996;25:107-112.
    • (1996) Jpn J Artif Organs , vol.25 , pp. 107-112
    • Hosoya, N.1    Sasaki, M.2    Takesawa, S.3
  • 5
    • 0017801107 scopus 로고
    • Simultaneous hemofiltration/hemodialysis: An effective alternative to hemofiltration and conventional hemodialysis in the treatment of uremic patients
    • Leber HW, Wizemann V, Goubeaud G, Rawer P, Schutterle G: Simultaneous hemofiltration/hemodialysis: An effective alternative to hemofiltration and conventional hemodialysis in the treatment of uremic patients. Clin Nephrol 1978;9:115-121.
    • (1978) Clin Nephrol , vol.9 , pp. 115-121
    • Leber, H.W.1    Wizemann, V.2    Goubeaud, G.3    Rawer, P.4    Schutterle, G.5
  • 7
    • 0037591826 scopus 로고    scopus 로고
    • Effect of hollow fiber length on solute removal and quantification of internal filtration rate by Doppler ultrasound
    • Sato Y, Mineshima M, Ishimori I, Kaneko I, Akiba T, Teraoka S: Effect of hollow fiber length on solute removal and quantification of internal filtration rate by Doppler ultrasound. Int J Artif Organs 2003;26:129-134.
    • (2003) Int J Artif Organs , vol.26 , pp. 129-134
    • Sato, Y.1    Mineshima, M.2    Ishimori, I.3    Kaneko, I.4    Akiba, T.5    Teraoka, S.6
  • 8
    • 0027453650 scopus 로고
    • Bulk mass transport limitations during high-flux hemodialysis
    • Zydney AL: Bulk mass transport limitations during high-flux hemodialysis. Artif Organs 1993;17:919-924.
    • (1993) Artif Organs , vol.17 , pp. 919-924
    • Zydney, A.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.