메뉴 건너뛰기




Volumn 30, Issue 10, 2005, Pages 1747-1758

Experimental determination of the energy efficiency of an air-cooled chiller under part load conditions

Author keywords

[No Author keywords available]

Indexed keywords

BUILDINGS; CLIMATOLOGY; CONDENSATION; ELECTRIC LOADS; ELECTRICITY; ENERGY EFFICIENCY;

EID: 12444262196     PISSN: 03605442     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.energy.2004.11.007     Document Type: Article
Times cited : (57)

References (18)
  • 1
    • 0037409653 scopus 로고    scopus 로고
    • Strategy for prioritising interactive measures for enhancing energy efficiency of air-conditioned buildings
    • Lee WL, Yik FWH, Jones P. A strategy for prioritising interactive measures for enhancing energy efficiency of air-conditioned buildings. Energy 2003;28:877-93.
    • (2003) Energy , vol.28 , pp. 877-893
    • Lee, W.L.1    Yik, F.W.H.2    Jones, P.A.3
  • 2
    • 0035197414 scopus 로고    scopus 로고
    • Predicting air-conditioning energy consumption of a group of buildings using different heat rejection methods
    • Yik FWH, Burnett J, Prescott I. Predicting air-conditioning energy consumption of a group of buildings using different heat rejection methods. Energy Build 2001;33:151-66.
    • (2001) Energy Build , vol.33 , pp. 151-166
    • Yik, F.W.H.1    Burnett, J.2    Prescott, I.3
  • 3
    • 0141887711 scopus 로고    scopus 로고
    • Energy analysis of commercial buildings in subtropical climates
    • Lam JC. Energy analysis of commercial buildings in subtropical climates. Build Environ 2000;35:19-26.
    • (2000) Build Environ , vol.35 , pp. 19-26
    • Lam, J.C.1
  • 4
    • 0348042926 scopus 로고    scopus 로고
    • Electricity use characteristics of purpose-built office buildings in subtropical climates
    • Lam JC, Chan RYC, Tsang CL, Li DHW. Electricity use characteristics of purpose-built office buildings in subtropical climates. Energy Convers Manage 2004;45(6):829-44.
    • (2004) Energy Convers Manage , vol.45 , Issue.6 , pp. 829-844
    • Lam, J.C.1    Chan, R.Y.C.2    Tsang, C.L.3    Li, D.H.W.4
  • 5
    • 0035450132 scopus 로고    scopus 로고
    • Energy saving by realistic design data for commercial buildings in Hong Kong
    • Lee WL, Yik FWH, Jones P, Burnett J. Energy saving by realistic design data for commercial buildings in Hong Kong. Appl Energy 2001:70:59-75.
    • (2001) Appl Energy , vol.70 , pp. 59-75
    • Lee, W.L.1    Yik, F.W.H.2    Jones, P.3    Burnett, J.4
  • 6
    • 0036106462 scopus 로고    scopus 로고
    • Part load efficiency of air-cooled multiple-chiller plant
    • Chan KT, Yu FW. Part load efficiency of air-cooled multiple-chiller plant. Building Serv Eng Res Technol 2002;23(1): 29-39.
    • (2002) Building Serv Eng Res Technol , vol.23 , Issue.1 , pp. 29-39
    • Chan, K.T.1    Yu, F.W.2
  • 8
    • 0026193946 scopus 로고
    • Optimum chiller loading
    • Austin SB. Optimum chiller loading. ASHRAE J 1991;33(7):40-3.
    • (1991) ASHRAE J , vol.33 , Issue.7 , pp. 40-43
    • Austin, S.B.1
  • 9
    • 0034831397 scopus 로고    scopus 로고
    • Measurement considerations for the determination of central plant efficiency
    • Treado SJ, Snouffer T. Measurement considerations for the determination of central plant efficiency. ASHRAE Trans 2001;107(1):401-6.
    • (2001) ASHRAE Trans , vol.107 , Issue.1 , pp. 401-406
    • Treado, S.J.1    Snouffer, T.2
  • 10
    • 58949096973 scopus 로고    scopus 로고
    • Performance evaluation of air-cooled chiller plants for improving design and operation
    • part 2 [On-line publications]
    • Yu FW, Chan KT. Performance evaluation of air-cooled chiller plants for improving design and operation. In: CIBSE national technical conference, 2002, part 2 [On-line publications]. Available at: http://www.cibse.org.
    • (2002) CIBSE National Technical Conference
    • Yu, F.W.1    Chan, K.T.2
  • 12
    • 85018031591 scopus 로고    scopus 로고
    • Heating piping air conditioning engineering
    • forum on ARI 550/590-98. May, [On-line serial]
    • Heating piping air conditioning engineering. forum on ARI 550/590-98. HPAC interactive feature May, 1999 [On-line serial]. Available at: http://hpac.com.
    • (1999) HPAC Interactive Feature
  • 14
    • 0036630063 scopus 로고    scopus 로고
    • Applying condensing-temperature control in air-cooled reciprocating water chillers for energy efficiency
    • Chan KT, Yu FW. Applying condensing-temperature control in air-cooled reciprocating water chillers for energy efficiency. Appl Energy 2002;72:565-81.
    • (2002) Appl Energy , vol.72 , pp. 565-581
    • Chan, K.T.1    Yu, F.W.2
  • 15
    • 2942733574 scopus 로고    scopus 로고
    • Optimum set point of condensing temperature for air-cooled chillers
    • Chan KT, Yu FW. Optimum set point of condensing temperature for air-cooled chillers. Int J HVAC&R Res 2004;10(2):113-27.
    • (2004) Int J HVAC&R Res , vol.10 , Issue.2 , pp. 113-127
    • Chan, K.T.1    Yu, F.W.2
  • 16
    • 11144251431 scopus 로고    scopus 로고
    • Condensing temperature control to enhance the efficiency of air-cooled chillers
    • Yu FW, Chan KT. Condensing temperature control to enhance the efficiency of air-cooled chillers. Build Services Eng Res Technol 2004;25(4):1-16.
    • (2004) Build Services Eng Res Technol , vol.25 , Issue.4 , pp. 1-16
    • Yu, F.W.1    Chan, K.T.2
  • 18
    • 0002618691 scopus 로고    scopus 로고
    • Energy saving controls for air-cooled water chillers
    • Smith M, King G. Energy saving controls for air-cooled water chillers. Build Services J 1998;47-8.
    • (1998) Build Services J , pp. 47-48
    • Smith, M.1    King, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.