-
1
-
-
0031389996
-
Medical aerosols: Techniques for particle size evaluation
-
Mitchell, J.P.; Nagel, M.W. Medical aerosols: techniques for particle size evaluation. Part. Sci. Technol. 1997, 15, 217-241.
-
(1997)
Part. Sci. Technol.
, vol.15
, pp. 217-241
-
-
Mitchell, J.P.1
Nagel, M.W.2
-
2
-
-
0032781887
-
Aerodynamic particle size of metered-dose inhalers determined by the quartz crystal microbalance and the Andersen cascade impactor
-
Tzou, T.-Z. Aerodynamic particle size of metered-dose inhalers determined by the quartz crystal microbalance and the Andersen cascade impactor. Int. J. Pharm. 1999, 186, 71-79.
-
(1999)
Int. J. Pharm.
, vol.186
, pp. 71-79
-
-
Tzou, T.-Z.1
-
3
-
-
0030969821
-
Metered dose inhalers. II. Particle size measurement variation
-
LeBelle, M.J.; Graham, S.J.; Ormsby, E.D.; Duhaime, R.M.; Lawrence, R.C. ; Pike, R.K. Metered dose inhalers. II. Particle size measurement variation. Int. J. Pharm. 1997, 151, 209-221.
-
(1997)
Int. J. Pharm.
, vol.151
, pp. 209-221
-
-
LeBelle, M.J.1
Graham, S.J.2
Ormsby, E.D.3
Duhaime, R.M.4
Lawrence, R.C.5
Pike, R.K.6
-
4
-
-
0002464443
-
Sampling inlet considerations in inertial particle-size analysis of inhalation aerosols
-
Hickey, A.J. Sampling inlet considerations in inertial particle-size analysis of inhalation aerosols. Pharm. Technol. 1995, 3, 58-67.
-
(1995)
Pharm. Technol.
, vol.3
, pp. 58-67
-
-
Hickey, A.J.1
-
5
-
-
0000913821
-
Effect of inlet throat on the correlation between measured fine particle dose and lung deposition
-
Dalby, R.N., Byron, P.R., Farr, S.J., Eds.; Interpharm Press: Buffalo Grove, IL
-
Olsson, B.; Borgstrom, L.; Asking, L.; Bondesson, E. Effect of inlet throat on the correlation between measured fine particle dose and lung deposition. In Respiratory Drug Delivery V; Dalby, R.N., Byron, P.R., Farr, S.J., Eds.; Interpharm Press: Buffalo Grove, IL, 1996; 273-281.
-
(1996)
Respiratory Drug Delivery V.
, pp. 273-281
-
-
Olsson, B.1
Borgstrom, L.2
Asking, L.3
Bondesson, E.4
-
6
-
-
1242349621
-
Understanding throat deposition during cascade impactor testing
-
Byron, P.R., Dalby, R.N., Peart, J., Farr, S.J., Eds.; DHI Publishing: Raleigh, NC
-
Stein, S.W.; Gabrio, B.J. Understanding throat deposition during cascade impactor testing. In Respiratory Drug Delivery VII; Byron, P.R., Dalby, R.N., Peart, J., Farr, S.J., Eds.; DHI Publishing: Raleigh, NC, 2000; 287-290.
-
(2000)
Respiratory Drug Delivery VII.
, pp. 287-290
-
-
Stein, S.W.1
Gabrio, B.J.2
-
7
-
-
0031832650
-
Metered dose inhaler aerosol deposition in a model of the human respiratory system and a comparison with clinical deposition studies
-
Velasquez, D.J.; Gabrio, B. Metered dose inhaler aerosol deposition in a model of the human respiratory system and a comparison with clinical deposition studies. J. Aerosol Med. 1998, 11 (Suppl. 1), S23-S28.
-
(1998)
J. Aerosol Med.
, vol.11
, Issue.SUPPL. 1
-
-
Velasquez, D.J.1
Gabrio, B.2
-
8
-
-
1242304605
-
-
United States Pharmacopeial Convention; Rockville, MD
-
USP25-NF20. In 〈601〉 General Chapter on Aerosols; United States Pharmacopeial Convention; Rockville, MD, 2002; 1964-1980.
-
(2002)
〈601〉 General Chapter on Aerosols
, pp. 1964-1980
-
-
-
9
-
-
0028807044
-
Particle size distribution of single and multiple sprays of salbutamol metered dose inhalers (MDIs)
-
Graham, S.J.; Lawrence, R.C.; Ormsby, E.D.; Pike, R.K. Particle size distribution of single and multiple sprays of salbutamol metered dose inhalers (MDIs). Pharm. Res. 1995, 12, 1380-1384.
-
(1995)
Pharm. Res.
, vol.12
, pp. 1380-1384
-
-
Graham, S.J.1
Lawrence, R.C.2
Ormsby, E.D.3
Pike, R.K.4
-
10
-
-
1242282308
-
-
California Measurements: Sierra Madre, CA
-
Impaq-6 Operating Manual; California Measurements: Sierra Madre, CA.
-
Impaq-6 Operating Manual
-
-
-
11
-
-
0004251768
-
-
Apparatus A (Glass Impinger)
-
European Pharmacopoeia. Apparatus A (Glass Impinger); 1997.
-
(1997)
European Pharmacopoeia
-
-
-
12
-
-
0028346278
-
Effects of chamber volume and geometry on aero-dynamic size distributions of metered dose inhalation aerosols measured using cascade impactor
-
Van Oort, M.; Gollmar, R.O.; Bohinski, R.J. Effects of chamber volume and geometry on aero-dynamic size distributions of metered dose inhalation aerosols measured using cascade impactor. Pharm. Res. 1994, 11, 604-607.
-
(1994)
Pharm. Res.
, vol.11
, pp. 604-607
-
-
Van Oort, M.1
Gollmar, R.O.2
Bohinski, R.J.3
-
13
-
-
0344172594
-
Micronization of pharmaceutical substances in a spiral jet mill
-
Midoux, N.; Hosek, P.; Pailleres, L.; Authelin, J.R. Micronization of pharmaceutical substances in a spiral jet mill. Powder Technol. 1999, 104, 113-120.
-
(1999)
Powder Technol.
, vol.104
, pp. 113-120
-
-
Midoux, N.1
Hosek, P.2
Pailleres, L.3
Authelin, J.R.4
-
14
-
-
0028146350
-
Surfactant promoted crystal growth of micronized methylprednisolone in trichloromonfluoromethane
-
Phillips, E.M.; Byron, P.R. Surfactant promoted crystal growth of micronized methylprednisolone in trichloromonfluoromethane. Int. J. Pharm. 1994, 110, 9-19.
-
(1994)
Int. J. Pharm.
, vol.110
, pp. 9-19
-
-
Phillips, E.M.1
Byron, P.R.2
|