-
1
-
-
0034110544
-
Partial dislocation of laser in situ keratomileusis flap by air bag injury
-
Lemley H.L., Chodosh J., Wolf T.C.et al. Partial dislocation of laser in situ keratomileusis flap by air bag injury. J Refract Surg. 16:2000;373-374.
-
(2000)
J Refract Surg
, vol.16
, pp. 373-374
-
-
Lemley, H.L.1
Chodosh, J.2
Wolf, T.C.3
-
2
-
-
0033955050
-
Traumatic partial unfolding of laser in situ keratomileusis flap with severe epithelial ingrowth
-
Leung A.T.S., Rao S.K., Lam D.S.C. Traumatic partial unfolding of laser in situ keratomileusis flap with severe epithelial ingrowth. J Cataract Refract Surg. 26:2000;135-139.
-
(2000)
J Cataract Refract Surg
, vol.26
, pp. 135-139
-
-
Leung, A.T.S.1
Rao, S.K.2
Lam, D.S.C.3
-
3
-
-
0033653323
-
Late traumatic dislocation of laser in situ keratomileusis corneal flaps
-
Melki S.A., Talamo J.H., Demetriades A.-M.et al. Late traumatic dislocation of laser in situ keratomileusis corneal flaps. Ophthalmology. 107:2000;2136-2139.
-
(2000)
Ophthalmology
, vol.107
, pp. 2136-2139
-
-
Melki, S.A.1
Talamo, J.H.2
Demetriades, A.-M.3
-
4
-
-
0035098201
-
Late dislocation of a LASIK flap caused by a fingernail
-
correction, 1565 and 2002; 120:180
-
Patel C.K., Hanson R., McDonald B., Cox N. Late dislocation of a LASIK flap caused by a fingernail. Arch Ophthalmol. 119:2001;447-448. correction, 1565 and 2002; 120:180.
-
(2001)
Arch Ophthalmol
, vol.119
, pp. 447-448
-
-
Patel, C.K.1
Hanson, R.2
McDonald, B.3
Cox, N.4
-
6
-
-
0034996413
-
Traumatic flap displacement and subsequent diffuse lamellar keratitis after laser in situ keratomileusis
-
Schwartz G.S., Park D.H., Schloff S., Lane S.S. Traumatic flap displacement and subsequent diffuse lamellar keratitis after laser in situ keratomileusis. J Cataract Refract Surg. 27:2001;781-783.
-
(2001)
J Cataract Refract Surg
, vol.27
, pp. 781-783
-
-
Schwartz, G.S.1
Park, D.H.2
Schloff, S.3
Lane, S.S.4
-
7
-
-
0034762119
-
Accidental self-removal of a flap - A rare complication of laser in situ keratomileusis surgery
-
Sridhar M.S., Rapuano C.J., Cohen E.J. Accidental self-removal of a flap - a rare complication of laser in situ keratomileusis surgery. Am J Ophthalmol. 132:2001;780-782.
-
(2001)
Am J Ophthalmol
, vol.132
, pp. 780-782
-
-
Sridhar, M.S.1
Rapuano, C.J.2
Cohen, E.J.3
-
8
-
-
0030985492
-
Quantification of stromal thinning, epithelial thickness, and corneal haze after photorefractive keratectomy using in vivo confocal microscopy
-
Møller-Pedersen T., Vogel M., Li H.F.et al. Quantification of stromal thinning, epithelial thickness, and corneal haze after photorefractive keratectomy using in vivo confocal microscopy. Ophthalmology. 104:1997;360-368.
-
(1997)
Ophthalmology
, vol.104
, pp. 360-368
-
-
Møller-Pedersen, T.1
Vogel, M.2
Li, H.F.3
-
9
-
-
0029942577
-
Quantitative three-dimensional confocal imaging of the cornea in situ and in vivo: System design and calibration
-
Petroll W.M., Jester JV Cavanagh HD Quantitative three-dimensional confocal imaging of the cornea in situ and in vivo. system design and calibration Scanning. 18:1996;45-49.
-
(1996)
Scanning
, vol.18
, pp. 45-49
-
-
Petroll, W.M.1
Jv Cavanagh Hd, J.2
-
10
-
-
0034896487
-
Late partial dislocation of a laser in situ keratomileusis flap
-
Lombardo A.J., Katz H.R. Late partial dislocation of a laser in situ keratomileusis flap. J Cataract Refract Surg. 27:2001;1108-1110.
-
(2001)
J Cataract Refract Surg
, vol.27
, pp. 1108-1110
-
-
Lombardo, A.J.1
Katz, H.R.2
-
12
-
-
0034007261
-
Confocal microscopy of a patient with irregular astigmatism after LASIK reoperations and relaxation incisions
-
Linna T.U., Vesaluoma M.H., Petroll W.M.et al. Confocal microscopy of a patient with irregular astigmatism after LASIK reoperations and relaxation incisions. Cornea. 19:2000;163-169.
-
(2000)
Cornea
, vol.19
, pp. 163-169
-
-
Linna, T.U.1
Vesaluoma, M.H.2
Petroll, W.M.3
|