메뉴 건너뛰기




Volumn 90, Issue 1, 2004, Pages 79-82

Progressive intra-acetabular dislocation of bipolar hip prostheses: Four cases;Dissociation progressive intra prothétique d'une prothèse intermédiaire de hanche: À propos de 4 cas

Author keywords

Intermediary hip prosthesis; Mechanical complications

Indexed keywords

ACETABULUM; AGED; ARTICLE; BONE GRAFT; CASE REPORT; DISEASE COURSE; DISLOCATION; FEMALE; FEMUR HEAD; FEMUR NECK; FEMUR NECK FRACTURE; HIP ARTHROPLASTY; HIP DISLOCATION; HIP PROSTHESIS; HUMAN; JOINT INSTABILITY; METHODOLOGY; PATHOLOGY; PROSTHESIS; PROSTHESIS FAILURE; PROSTHESIS LOOSENING; REOPERATION; WEIGHT BEARING;

EID: 1242339747     PISSN: 00351040     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0035-1040(04)70011-2     Document Type: Article
Times cited : (7)

References (10)
  • 1
    • 0005400584 scopus 로고
    • La prothèse intermédiaire dans les fractures du col du fémur
    • MERLO L, AUGEREAU B, APOIL A: La prothèse intermédiaire dans les fractures du col du fémur. Rev Chir Orthop, 1992, 78, 536-543.
    • (1992) Rev Chir Orthop , vol.78 , pp. 536-543
    • Merlo, L.1    Augereau, B.2    Apoil, A.3
  • 2
    • 0031309275 scopus 로고    scopus 로고
    • Dissociation de la cupule au cours de la réduction d'une luxation de prothèse de hanche intermédiaire
    • LOUBIGNAC F, BOISSIER F: Dissociation de la cupule au cours de la réduction d'une luxation de prothèse de hanche intermédiaire. Rev Chir Orthop, 1997, 83, 469-472.
    • (1997) Rev Chir Orthop , vol.83 , pp. 469-472
    • Loubignac, F.1    Boissier, F.2
  • 4
    • 0023968986 scopus 로고
    • Interprosthetic dislocation of the Charnley Hastings prostheses: Brief report
    • RAE PJ, PATON RW: Interprosthetic dislocation of the Charnley Hastings prostheses: brief report. J Bone Joint Surg (Br), 1988, 70, 330.
    • (1988) J Bone Joint Surg (Br) , vol.70 , pp. 330
    • Rae, P.J.1    Paton, R.W.2
  • 6
    • 0023492448 scopus 로고
    • Batman hemiarthroplasty component disassembly: A report of three cases of high-density polyethylene failure
    • ARMADA R, MESS D: Batman hemiarthroplasty component disassembly: a report of three cases of high-density polyethylene failure. Clin Orthop, 1987, 224, 147-149.
    • (1987) Clin Orthop , vol.224 , pp. 147-149
    • Armada, R.1    Mess, D.2
  • 7
    • 0030236764 scopus 로고    scopus 로고
    • Luxation-dissociation d'une prothèse bi-articulée de hanche
    • CORTEEL J, PUTZ PH: Luxation-dissociation d'une prothèse bi-articulée de hanche. Acta Orthop Belg, 1996, 62, 173-176.
    • (1996) Acta Orthop Belg , vol.62 , pp. 173-176
    • Corteel, J.1    Putz, P.H.2
  • 8
    • 0020077904 scopus 로고
    • Use of the Giliberty bipolar endoprosthesis in femoral neck fractures
    • BHULLER GS: Use of the Giliberty bipolar endoprosthesis in femoral neck fractures. Clin Orthop, 1982, 162, 165-169.
    • (1982) Clin Orthop , vol.162 , pp. 165-169
    • Bhuller, G.S.1
  • 9
    • 0021672633 scopus 로고
    • Biomechanics of bipolar hip endoprostheses
    • KREIN SV, CHAO EYS: Biomechanics of bipolar hip endoprostheses. J Orthop Res, 1984, 2, 356-358.
    • (1984) J Orthop Res , vol.2 , pp. 356-358
    • Krein, S.V.1    Chao, E.Y.S.2
  • 10
    • 0029786789 scopus 로고    scopus 로고
    • Bipolar femoral head arthroplasty in osteoarthitis: A prospective study with a minimum of 5 year follow-up period
    • PANDIT R: Bipolar femoral head arthroplasty in osteoarthitis: a prospective study with a minimum of 5 year follow-up period. J Arthroplasty, 1996, 11, 560-564.
    • (1996) J Arthroplasty , vol.11 , pp. 560-564
    • Pandit, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.