Volumn 84, Issue 1, 2004, Pages 91-123

Ventricular assist devices as destination therapy

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL HEART; ASSISTED CIRCULATION; BLOOD PUMP; CARDIOPULMONARY BYPASS; CIRCULATION; CONGESTIVE HEART FAILURE; DEVICE; HEART LEFT VENTRICLE; HEART TRANSPLANTATION; HUMAN; MEDICAL ASSESSMENT; MULTIPLE ORGAN FAILURE; PRIORITY JOURNAL; PROSPECTIVE STUDY; PULSE PRESSURE; RANDOMIZATION; RELIABILITY; REVIEW;

EID: 1242338882     PISSN: 00396109     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.suc.2003.12.010     Document Type: Review
Times cited : (26)

References (47)
  • 1
    • 0014985060 scopus 로고
    • Left ventricular bypass pump for cardiac assistance. Clinical experience
    • DeBakey M.E. Left ventricular bypass pump for cardiac assistance. Clinical experience. Am J Cardiol. 27:1971;3-11.
    • (1971) Am J Cardiol , vol.27 , pp. 3-11
    • Debakey, M.E.1
  • 2
    • 0014222051 scopus 로고
    • The operation. A human cardiac transplant: An interim report of a successful operation performed at Groote Schuur Hospital, Cape Town
    • Barnard C.N. The operation. A human cardiac transplant: an interim report of a successful operation performed at Groote Schuur Hospital, Cape Town. S Afr Med J. 41:1967;1271-1274.
    • (1967) S Afr Med J , vol.41 , pp. 1271-1274
    • Barnard, C.N.1
  • 3
    • 1242266769 scopus 로고    scopus 로고
    • Mechanical circulatory support
    • Oxford (United Kingdom): Isis Medical Media
    • Westaby S. Mechanical circulatory support. Landmarks in cardiac surgery. 1997;279-305 Isis Medical Media, Oxford (United Kingdom).
    • (1997) Landmarks in Cardiac Surgery , pp. 279-305
    • Westaby, S.1
  • 4
    • 0021335346 scopus 로고
    • Clinical use of the total artificial heart
    • Devries W.C., Anderson J.L., Joyce L.D., et al. Clinical use of the total artificial heart. N Engl J Med. 310:1984;273-278.
    • (1984) N Engl J Med , vol.310 , pp. 273-278
    • Devries, W.C.1    Anderson, J.L.2    Joyce, L.D.3
  • 5
    • 0030813936 scopus 로고    scopus 로고
    • International experience with the Cardio West total artificial heart as a bridge to heart transplantation
    • Arabia F.A., Copeland J.B., Smith R.G., et al. International experience with the Cardio West total artificial heart as a bridge to heart transplantation. Euro J Cardiothorac Surg. 11:(Suppl):1997;S5-S10.
    • (1997) Euro J Cardiothorac Surg , vol.11 , Issue.SUPPL
    • Arabia, F.A.1    Copeland, J.B.2    Smith, R.G.3
  • 6
    • 0036151079 scopus 로고    scopus 로고
    • Cardiac transplantation
    • Deng M.C. Cardiac transplantation. Heart. 87:2002;177-184.
    • (2002) Heart , vol.87 , pp. 177-184
    • Deng, M.C.1
  • 7
    • 0037778809 scopus 로고    scopus 로고
    • Effect of receiving a heart transplant: Analysis of a national cohort entered onto a waiting list, stratified by heart failure severity
    • Deng M.C., De Meester J.M.J., Smits J.M.A., et al. Effect of receiving a heart transplant: analysis of a national cohort entered onto a waiting list, stratified by heart failure severity. BMJ. 321:2000;540-545.
    • (2000) BMJ , vol.321 , pp. 540-545
    • Deng, M.C.1    De Meester, J.M.J.2    Smits, J.M.A.3
  • 8
    • 0033931661 scopus 로고    scopus 로고
    • Mechanical bridge to recovery in fulminant myocarditis
    • Westaby S., Katsumata T., Pigott D., et al. Mechanical bridge to recovery in fulminant myocarditis. Ann Thorac Surg. 70:2000;278-283.
    • (2000) Ann Thorac Surg , vol.70 , pp. 278-283
    • Westaby, S.1    Katsumata, T.2    Pigott, D.3
  • 9
    • 0030246896 scopus 로고    scopus 로고
    • Improved left ventricular function after chronic left ventricular unloading
    • Frazier O.H., Benedict G.G., Radovancevich B., et al. Improved left ventricular function after chronic left ventricular unloading. Ann Thorac Surg. 62:1996;675-682.
    • (1996) Ann Thorac Surg , vol.62 , pp. 675-682
    • Frazier, O.H.1    Benedict, G.G.2    Radovancevich, B.3
  • 10
    • 0343765713 scopus 로고    scopus 로고
    • Weaning from mechanical cardiac support in patients with idiopathic dilated cardiomyopathy
    • Muller J., Wallukat G., Weng Y., et al. Weaning from mechanical cardiac support in patients with idiopathic dilated cardiomyopathy. Circulation. 96:1997;542-549.
    • (1997) Circulation , vol.96 , pp. 542-549
    • Muller, J.1    Wallukat, G.2    Weng, Y.3
  • 11
    • 0034122952 scopus 로고    scopus 로고
    • Nontransplant surgery for heart failure
    • Westaby S. Nontransplant surgery for heart failure. Heart. 803:2000;603-610.
    • (2000) Heart , vol.803 , pp. 603-610
    • Westaby, S.1
  • 12
    • 0032547931 scopus 로고    scopus 로고
    • Implantable left ventricular assist devices
    • Goldstein D.J., Oz M.C., Rose E.A. Implantable left ventricular assist devices. N Engl J Med. 339:1998;1522-1533.
    • (1998) N Engl J Med , vol.339 , pp. 1522-1533
    • Goldstein, D.J.1    Oz, M.C.2    Rose, E.A.3
  • 13
    • 0032568489 scopus 로고    scopus 로고
    • Mechanical circulatory support and cardiac transplantation
    • Hunt S.A., Frazier O.H., Myers T. Mechanical circulatory support and cardiac transplantation. Circulation. 97:1998;2079-2080.
    • (1998) Circulation , vol.97 , pp. 2079-2080
    • Hunt, S.A.1    Frazier, O.H.2    Myers, T.3
  • 14
    • 0028232710 scopus 로고
    • First use of an untethered, vented electric left ventricular assist device for long-term support
    • Frazier O.H. First use of an untethered, vented electric left ventricular assist device for long-term support. Circulation. 89:1994;2908-2914.
    • (1994) Circulation , vol.89 , pp. 2908-2914
    • Frazier, O.H.1
  • 15
    • 0031839657 scopus 로고    scopus 로고
    • Cerebral and systemic embolization during left ventricular support with the Novacor N100 device
    • Schmid C., Wyaand M., Navabi D.G., et al. Cerebral and systemic embolization during left ventricular support with the Novacor N100 device. Ann Thorac Surg. 65:1998;1703-1710.
    • (1998) Ann Thorac Surg , vol.65 , pp. 1703-1710
    • Schmid, C.1    Wyaand, M.2    Navabi, D.G.3
  • 16
    • 0029113695 scopus 로고
    • Improved mortality and rehabilitation of transplant candidates treated with long-term implantable left ventricular assist system
    • Frazier O.H., Rose E.A., McCarthy P., et al. Improved mortality and rehabilitation of transplant candidates treated with long-term implantable left ventricular assist system. Ann Surg. 222:1995;327-336.
    • (1995) Ann Surg , vol.222 , pp. 327-336
    • Frazier, O.H.1    Rose, E.A.2    McCarthy, P.3
  • 17
    • 1242289442 scopus 로고    scopus 로고
    • Improved survival after extended bridge to cardiac transplantation
    • Frazier O.H., Macris M.P., Myers T.T., et al. Improved survival after extended bridge to cardiac transplantation. Ann Thorac Surg. 61:1996;342-346.
    • (1996) Ann Thorac Surg , vol.61 , pp. 342-346
    • Frazier, O.H.1    MacRis, M.P.2    Myers, T.T.3
  • 18
    • 0036899948 scopus 로고    scopus 로고
    • Do left ventricular assist device (LVAD) bridge to transplantation outcomes predict the results of permanent LVAD implantation?
    • Navia J.L., McCarthy P.M., Hoercher K.J., et al. Do left ventricular assist device (LVAD) bridge to transplantation outcomes predict the results of permanent LVAD implantation? Ann Thorac Surg. 74:2002;2051-2063.
    • (2002) Ann Thorac Surg , vol.74 , pp. 2051-2063
    • Navia, J.L.1    McCarthy, P.M.2    Hoercher, K.J.3
  • 19
    • 0345347290 scopus 로고
    • Artificial circulatory support with textured interior surfaces. A counterintuitive approach to minimizing thromboembolism
    • Rose E.A., Levin H.R., Oz M.C., et al. Artificial circulatory support with textured interior surfaces. A counterintuitive approach to minimizing thromboembolism. Circulation. 90:(Supp II):1994;1187-1191.
    • (1994) Circulation , vol.90 , Issue.SUPP II , pp. 1187-1191
    • Rose, E.A.1    Levin, H.R.2    Oz, M.C.3
  • 20
    • 0030019455 scopus 로고    scopus 로고
    • Implantable LVAD infections: Implications for permanent use of the device
    • McCarthy P.M., Schmidt S.K., Vargo R.L., et al. Implantable LVAD infections: implications for permanent use of the device. Ann Thorac Surg. 61:1996;359-365.
    • (1996) Ann Thorac Surg , vol.61 , pp. 359-365
    • McCarthy, P.M.1    Schmidt, S.K.2    Vargo, R.L.3
  • 21
    • 0036895798 scopus 로고    scopus 로고
    • Adverse events in the use of Heart Mate vented electric and Novacor left ventricular assist devices: Comparing apples and oranges
    • Pasque M.K., Rogers J.A. Adverse events in the use of Heart Mate vented electric and Novacor left ventricular assist devices: comparing apples and oranges. J Thorac Cardiovasc Surg. 124:2002;1063-1067.
    • (2002) J Thorac Cardiovasc Surg , vol.124 , pp. 1063-1067
    • Pasque, M.K.1    Rogers, J.A.2
  • 22
    • 0000576204 scopus 로고    scopus 로고
    • Low thromboembolic risk without anticoagulation using advanced design left ventricular assist devices
    • Slater J.P., Rose E.A., Levin H.R., et al. Low thromboembolic risk without anticoagulation using advanced design left ventricular assist devices. Ann Thorac Surg. 62:1996;1321-1327.
    • (1996) Ann Thorac Surg , vol.62 , pp. 1321-1327
    • Slater, J.P.1    Rose, E.A.2    Levin, H.R.3
  • 23
    • 0035892018 scopus 로고    scopus 로고
    • Long-term use of a left ventricular assist device for end-stage heart failure
    • Rose E.A., Gelijns A.L., Moskowitz A.J., et al. Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med. 345:2001;435-443.
    • (2001) N Engl J Med , vol.345 , pp. 435-443
    • Rose, E.A.1    Gelijns, A.L.2    Moskowitz, A.J.3
  • 24
    • 0030019456 scopus 로고    scopus 로고
    • Results of extended bridge to transplantation: Window into the future of permanent ventricular assist devices
    • Griffiths B.P., Kormos R.L., Nastala C.J., Winowich S., Pristas J.M. Results of extended bridge to transplantation: window into the future of permanent ventricular assist devices. Ann Thorac Surg. 61:1996;396-398.
    • (1996) Ann Thorac Surg , vol.61 , pp. 396-398
    • Griffiths, B.P.1    Kormos, R.L.2    Nastala, C.J.3    Winowich, S.4    Pristas, J.M.5
  • 25
    • 0032514604 scopus 로고    scopus 로고
    • Jarvik 2000 Heart: Potential for bridge to myocardial recovery
    • Westaby S., Katsumata T., Hovel R., et al. Jarvik 2000 Heart: potential for bridge to myocardial recovery. Circulation. 98:1998;1568-1574.
    • (1998) Circulation , vol.98 , pp. 1568-1574
    • Westaby, S.1    Katsumata, T.2    Hovel, R.3
  • 26
    • 0037129864 scopus 로고    scopus 로고
    • Initial critical experience with the Jarvik 2000 implantable axial flow left ventricular assist system
    • Frazier O.H., Myers T.J., Gregoric I.D., et al. Initial critical experience with the Jarvik 2000 implantable axial flow left ventricular assist system. Circulation. 105:2002;2855-2860.
    • (2002) Circulation , vol.105 , pp. 2855-2860
    • Frazier, O.H.1    Myers, T.J.2    Gregoric, I.D.3
  • 27
    • 0037024232 scopus 로고    scopus 로고
    • Circulatory support as long-term treatment for heart failure. Experience with an intraventricular continuous flow pump
    • Westaby S., Banning A., Saito S., et al. Circulatory support as long-term treatment for heart failure. Experience with an intraventricular continuous flow pump. Circulation. 105:2002;2588-2591.
    • (2002) Circulation , vol.105 , pp. 2588-2591
    • Westaby, S.1    Banning, A.2    Saito, S.3
  • 28
    • 0032005727 scopus 로고    scopus 로고
    • LVAD power delivery: A percutaneous approach to avoid infection
    • Jarvik R., Westaby S., Katsumata T., et al. LVAD power delivery: a percutaneous approach to avoid infection. Ann Thorac Surg. 64:1998;470-473.
    • (1998) Ann Thorac Surg , vol.64 , pp. 470-473
    • Jarvik, R.1    Westaby, S.2    Katsumata, T.3
  • 29
    • 0025053998 scopus 로고
    • Percutaneous pedestal in cochlear implantation
    • Parkin J.L. Percutaneous pedestal in cochlear implantation. Ann Otol Rhinol Laryngol. 99:1990;796-800.
    • (1990) Ann Otol Rhinol Laryngol , vol.99 , pp. 796-800
    • Parkin, J.L.1
  • 30
    • 0036205773 scopus 로고    scopus 로고
    • Implant technique for the Jarvik 2000 heart
    • Westaby S., Frazier O.H., Pigott D.W., et al. Implant technique for the Jarvik 2000 heart. Ann Thorac Surg. 73:2002;1337-1340.
    • (2002) Ann Thorac Surg , vol.73 , pp. 1337-1340
    • Westaby, S.1    Frazier, O.H.2    Pigott, D.W.3
  • 31
    • 0032711169 scopus 로고    scopus 로고
    • A miniature implantable axial flow ventricular assist device
    • DeBakey M.E. A miniature implantable axial flow ventricular assist device. Ann Thorac Surg. 68:1999;637-640.
    • (1999) Ann Thorac Surg , vol.68 , pp. 637-640
    • Debakey, M.E.1
  • 32
    • 0034074215 scopus 로고    scopus 로고
    • Development and clinical application of the Micromed DeBakey VAD
    • Noon G.P., Morley D., Irwin S., Benkowski R. Development and clinical application of the Micromed DeBakey VAD. Curr Opin Cardiol. 15:2000;166-171.
    • (2000) Curr Opin Cardiol , vol.15 , pp. 166-171
    • Noon, G.P.1    Morley, D.2    Irwin, S.3    Benkowski, R.4
  • 33
    • 0035106218 scopus 로고    scopus 로고
    • HeartMate II left ventricular assist system: From concept to first clinical use
    • Griffith B.P., Kormos R.L., Borovetz H.S., et al. HeartMate II left ventricular assist system: from concept to first clinical use. Ann Thorac Surg. 71:2001;s116-s120.
    • (2001) Ann Thorac Surg , vol.71
    • Griffith, B.P.1    Kormos, R.L.2    Borovetz, H.S.3
  • 34
    • 12944281172 scopus 로고    scopus 로고
    • Terumo left ventricular assist system. Results of a long-term animal study
    • Nojiri C., Kijima T., Maekawa U., et al. Terumo left ventricular assist system. Results of a long-term animal study. ASAIO J. 46:2000;117-122.
    • (2000) ASAIO J , vol.46 , pp. 117-122
    • Nojiri, C.1    Kijima, T.2    Maekawa, U.3
  • 35
    • 0035022377 scopus 로고    scopus 로고
    • Reliable long term non pulsatile circulatory support without anticoagulation
    • Saito S., Westaby S., Pigott D., et al. Reliable long term non pulsatile circulatory support without anticoagulation. Eur J Cardiothorac Surg. 19:2001;678-683.
    • (2001) Eur J Cardiothorac Surg , vol.19 , pp. 678-683
    • Saito, S.1    Westaby, S.2    Pigott, D.3
  • 37
    • 0034823947 scopus 로고    scopus 로고
    • HeartMate left ventricular assist devices: A multi generation of implanted blood pumps
    • Maher T.R., Butler K.C., Poirer V.L. HeartMate left ventricular assist devices: a multi generation of implanted blood pumps. Artif Organs. 25:2001;422-426.
    • (2001) Artif Organs , vol.25 , pp. 422-426
    • Maher, T.R.1    Butler, K.C.2    Poirer, V.L.3
  • 38
    • 0035103338 scopus 로고    scopus 로고
    • The Lionheart LVD-2000, a completely implantable left ventricular assist device for chronic circulatory support
    • Mehta S.M., Pae W.E., Rosenberg G., et al. The Lionheart LVD-2000, a completely implantable left ventricular assist device for chronic circulatory support. Ann Thorac Surg. 71:2001;S156-S161.
    • (2001) Ann Thorac Surg , vol.71
    • Mehta, S.M.1    Pae, W.E.2    Rosenberg, G.3
  • 39
    • 0029033797 scopus 로고
    • Reversal of chronic ventricular dilation in patients with end-stage cardiomyopathy by prolonged mechanical unloading
    • Levin H.R., Oz M.C., Chen J.M., et al. Reversal of chronic ventricular dilation in patients with end-stage cardiomyopathy by prolonged mechanical unloading. Circulation. 91:1995;2717-2720.
    • (1995) Circulation , vol.91 , pp. 2717-2720
    • Levin, H.R.1    Oz, M.C.2    Chen, J.M.3
  • 40
    • 0032895304 scopus 로고    scopus 로고
    • Altered levels of mRNA of apoptosis-mediating genes after midterm mechanical ventricular support and dilative cardiomyopathy: First results of the HALLE Assist Induced Recovery study (HAIR)
    • Milting H., Bartling B., Schumann H., et al. Altered levels of mRNA of apoptosis-mediating genes after midterm mechanical ventricular support and dilative cardiomyopathy: first results of the HALLE Assist Induced Recovery study (HAIR). Thorac Cardiovasc Surg. 47:1999;48-50.
    • (1999) Thorac Cardiovasc Surg , vol.47 , pp. 48-50
    • Milting, H.1    Bartling, B.2    Schumann, H.3
  • 41
    • 0032544226 scopus 로고    scopus 로고
    • Regression of cellular hypertrophy after left ventricular assist device support
    • Zafeiridis A., Jeevanandam V., Houser S.R., Margulies K.B. Regression of cellular hypertrophy after left ventricular assist device support. Circulation. 98:1998;656-662.
    • (1998) Circulation , vol.98 , pp. 656-662
    • Zafeiridis, A.1    Jeevanandam, V.2    Houser, S.R.3    Margulies, K.B.4
  • 42
    • 0037117144 scopus 로고    scopus 로고
    • Molecular remodeling of dystrophia in patients with end-stage cardiomathies and reversal in patients as assistance device therapy
    • Vatta M., Stetson S.J., Perez-Verdia A., et al. Molecular remodeling of dystrophia in patients with end-stage cardiomathies and reversal in patients as assistance device therapy. Lancet. 359:2000;936-941.
    • (2000) Lancet , vol.359 , pp. 936-941
    • Vatta, M.1    Stetson, S.J.2    Perez-Verdia, A.3
  • 43
    • 0031868498 scopus 로고    scopus 로고
    • Improvement of myocardial mitochrondrial function after haemodynamic support with left ventricular assist devices in patients with heart failure
    • Lee S.H., Doliba N., Osbakken M., et al. Improvement of myocardial mitochrondrial function after haemodynamic support with left ventricular assist devices in patients with heart failure. Thorac Cardiovasc Surg. 116:1998;344-349.
    • (1998) Thorac Cardiovasc Surg , vol.116 , pp. 344-349
    • Lee, S.H.1    Doliba, N.2    Osbakken, M.3
  • 44
    • 1242289443 scopus 로고    scopus 로고
    • Clinical experience with an implantable intra cardiac continuous flow circulatory support device: Physiologic implications and patient selection
    • in press
    • Frazier O.H., Myers T.J., Westaby S., Gregoric I.D. Clinical experience with an implantable intra cardiac continuous flow circulatory support device: physiologic implications and patient selection. Ann Thorac Surg. 2003;. in press.
    • (2003) Ann Thorac Surg
    • Frazier, O.H.1    Myers, T.J.2    Westaby, S.3    Gregoric, I.D.4
  • 45
    • 0005828721 scopus 로고    scopus 로고
    • Atrophy of myocardium and its myocytes by left ventricular assist device
    • Soloff L.A. Atrophy of myocardium and its myocytes by left ventricular assist device. Circulation. 98:1998;1012.
    • (1998) Circulation , vol.98 , pp. 1012
    • Soloff, L.A.1
  • 46
    • 0028469276 scopus 로고
    • Ventricular interaction during mechanical circulatory support
    • Farrar D.J. Ventricular interaction during mechanical circulatory support. Semin Thorac Cardiovasc Surg. 6:1994;163-168.
    • (1994) Semin Thorac Cardiovasc Surg , vol.6 , pp. 163-168
    • Farrar, D.J.1
  • 47
    • 0033625183 scopus 로고    scopus 로고
    • Alterations in calcium cycling protein and g-alpha-q signaling after left ventricular assist device supporting failing human hearts
    • Takeishi Y., Jalili T., Hoit B.D., et al. Alterations in calcium cycling protein and g-alpha-q signaling after left ventricular assist device supporting failing human hearts. Cardiovasc Res. 45:2000;883-888.
    • (2000) Cardiovasc Res , vol.45 , pp. 883-888
    • Takeishi, Y.1    Jalili, T.2    Hoit, B.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.