메뉴 건너뛰기




Volumn 31, Issue 2, 2004, Pages 368-375

Beamlet dose distribution compression and reconstruction using wavelets for intensity modulated treatment planning

Author keywords

Beamlets; Intensity modulated radiation therapy; Treatment planning; Wavelets

Indexed keywords

DIGITAL STORAGE; MATRIX ALGEBRA; MEAN SQUARE ERROR; WAVELET DECOMPOSITION;

EID: 1242316311     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1636560     Document Type: Article
Times cited : (16)

References (20)
  • 1
    • 0035999394 scopus 로고    scopus 로고
    • Acceleration of intensity-modulated radiotherapy dose calculation by importance sampling of the calculation matrices
    • C. Thieke, S. Nill, U. Oelfke, and T. Bortfeld, "Acceleration of intensity-modulated radiotherapy dose calculation by importance sampling of the calculation matrices," Med. Phys. 29, 676-681 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 676-681
    • Thieke, C.1    Nill, S.2    Oelfke, U.3    Bortfeld, T.4
  • 2
    • 0032016446 scopus 로고    scopus 로고
    • Inverse radiotherapy planning for intensity-modulated photon fields
    • K. Preiser, T. Bortfeld, K. Hartwig, W. Schlegel, and J. Stein, "Inverse radiotherapy planning for intensity-modulated photon fields, " Radiologe 38, 228-234 (1998).
    • (1998) Radiologe , vol.38 , pp. 228-234
    • Preiser, K.1    Bortfeld, T.2    Hartwig, K.3    Schlegel, W.4    Stein, J.5
  • 3
    • 0034977529 scopus 로고    scopus 로고
    • Acceleration of dose calculations for intensity-modulated radiotherapy
    • J. V. Siebers, S. D. Tong, M. Lauterbach, Q. W. Wu, and R. Mohan, "Acceleration of dose calculations for intensity-modulated radiotherapy," Med. Phys. 28, 903-910 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 903-910
    • Siebers, J.V.1    Tong, S.D.2    Lauterbach, M.3    Wu, Q.W.4    Mohan, R.5
  • 4
    • 0033916364 scopus 로고    scopus 로고
    • Monte Carlo dose computation for IMRT optimization
    • W. Laub, M. Alber, M. Birkner, and F. Nusslin, "Monte Carlo dose computation for IMRT optimization," Phys. Med. Biol. 45, 1741-1754 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 1741-1754
    • Laub, W.1    Alber, M.2    Birkner, M.3    Nusslin, F.4
  • 5
    • 0037034109 scopus 로고    scopus 로고
    • The effect of dose calculation accuracy on inverse treatment planning
    • R. Jeraj, P. J. Keall, and J. V. Siebers, "The effect of dose calculation accuracy on inverse treatment planning," Phys. Med. Biol. 47, 391-407 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 391-407
    • Jeraj, R.1    Keall, P.J.2    Siebers, J.V.3
  • 6
    • 0034986809 scopus 로고    scopus 로고
    • Intensity modulated irradiation of a thorax phantom: Comparisons between measurements, Monte Carlo calculations and pencil beam calculations
    • W. U. Laub, A. Bakai, and F. Nusslin, "Intensity modulated irradiation of a thorax phantom: Comparisons between measurements, Monte Carlo calculations and pencil beam calculations," Phys. Med. Biol. 46, 1695-1706 (2001).
    • (2001) Phys. Med. Biol. , vol.46 , pp. 1695-1706
    • Laub, W.U.1    Bakai, A.2    Nusslin, F.3
  • 8
    • 0035005898 scopus 로고    scopus 로고
    • Reduction of computational dimensionality in inverse radiotherapy planning using sparse matrix operations
    • P. S. Cho and M. H. Phillips, "Reduction of computational dimensionality in inverse radiotherapy planning using sparse matrix operations," Phys. Med. Biol. 46, N117-N125 (2001).
    • (2001) Phys. Med. Biol. , vol.46
    • Cho, P.S.1    Phillips, M.H.2
  • 10
    • 0026750950 scopus 로고
    • A pencil beam model for photon dose calculation
    • A. Ahnesjo, M. Saxner, and A. Trepp, "A pencil beam model for photon dose calculation," Med. Phys. 19, 263-273 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 263-273
    • Ahnesjo, A.1    Saxner, M.2    Trepp, A.3
  • 12
    • 0036797123 scopus 로고    scopus 로고
    • Accelerating Monte Carlo simulations of radiation therapy dose distributions using wavelet threshold de-noising
    • J. O. Deasy, M. V. Wickerhauser, and M. Picard, "Accelerating Monte Carlo simulations of radiation therapy dose distributions using wavelet threshold de-noising," Med. Phys. 29, 2366-2373 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2366-2373
    • Deasy, J.O.1    Wickerhauser, M.V.2    Picard, M.3
  • 13
    • 0030934371 scopus 로고    scopus 로고
    • Improved modeling of multiple scattering in the Voxel Monte Carlo model
    • I. Kawrakow, "Improved modeling of multiple scattering in the Voxel Monte Carlo model," Med. Phys. 24, 505-517 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 505-517
    • Kawrakow, I.1
  • 17
    • 0026686048 scopus 로고
    • Entropy-based algorithms for best basis selection
    • R. R. Coifman and M. V. Wickerhauser, "Entropy-based algorithms for best basis selection," IEEE Trans. Inf. Theory 38, 713-718 (1992).
    • (1992) IEEE Trans. Inf. Theory , vol.38 , pp. 713-718
    • Coifman, R.R.1    Wickerhauser, M.V.2
  • 18
    • 0027873602 scopus 로고
    • Unconditional bases are optimal bases for data compression and for statistical estimation
    • D. Donoho, "Unconditional bases are optimal bases for data compression and for statistical estimation," Appl. Comp. Harm. Anal. 1, 100-115 (1993).
    • (1993) Appl. Comp. Harm. Anal. , vol.1 , pp. 100-115
    • Donoho, D.1
  • 19
    • 0041958932 scopus 로고
    • Ideal spatial adaptation by wavelet shrinkage
    • D. L. Donoho and I. M. Johnstone, "Ideal spatial adaptation by wavelet shrinkage," Biometrika 81, 425-455 (1994).
    • (1994) Biometrika , vol.81 , pp. 425-455
    • Donoho, D.L.1    Johnstone, I.M.2
  • 20
    • 0041958932 scopus 로고
    • Adapting to unknown smoothness via wavelet shrinkage
    • D. L. Donoho and I. M. Johnstone, "Adapting to unknown smoothness via wavelet shrinkage," Biometrika 81, 425-455 (1994).
    • (1994) Biometrika , vol.81 , pp. 425-455
    • Donoho, D.L.1    Johnstone, I.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.