메뉴 건너뛰기




Volumn 4, Issue 4, 2003, Pages 125-139

Magnetic resonance techniques in hemodialysis access management

Author keywords

Flow quantification; Interventional magnetic resonance; Magnetic resonance angiography; Magnetic resonance imaging; Vascular access

Indexed keywords

BLOOD FLOW; CATHETER ABLATION; CONTRAST ENHANCEMENT; HEMODIALYSIS; HUMAN; IMAGING SYSTEM; INTERVENTIONAL RADIOLOGY; LOW LEVEL LASER THERAPY; MAGNETIC RESONANCE ANGIOGRAPHY; MEDICAL LITERATURE; MEDICAL RESEARCH; PHLEBOGRAPHY; QUANTITATIVE ANALYSIS; RADIOLOGICAL PARAMETERS; REVIEW; ULTRASOUND THERAPY; VASCULAR ACCESS;

EID: 1242274585     PISSN: 11297298     EISSN: None     Source Type: Journal    
DOI: 10.1177/112972980300400401     Document Type: Review
Times cited : (6)

References (53)
  • 1
    • 0035228229 scopus 로고    scopus 로고
    • Clinical practice guidelines for vascular access
    • National Kidney Foundation: Kidney Disease Outcomes Quality Initiative (NKF K/DOQI)
    • National Kidney Foundation: Kidney Disease Outcomes Quality Initiative (NKF K/DOQI). Clinical practice guidelines for vascular access. Am J Kidney Dis 2001; 37 (suppl 1): S137-81.
    • (2001) Am. J. Kidney Dis. , vol.37 , Issue.SUPPL. 1
  • 2
    • 1242303730 scopus 로고    scopus 로고
    • Dialysis Access: A multidisciplinary approach
    • (editor), (assistant editor). Philadelphia: Lippincott Williams & Wilkins
    • Gray RJ (editor), Sands JJ (assistant editor). Dialysis Access: A multidisciplinary approach. Philadelphia: Lippincott Williams & Wilkins, 2002.
    • (2002)
    • Gray, R.J.1    Sands, J.J.2
  • 3
    • 0027478504 scopus 로고
    • Central venous occlusion: MR angiography
    • Finn JP, Zisk JHS, Edelman RR, et al. Central venous occlusion: MR angiography. Radiology 1993; 187: 245-51.
    • (1993) Radiology , vol.187 , pp. 245-251
    • Finn, J.P.1    Zisk, J.H.S.2    Edelman, R.R.3
  • 4
    • 0028923446 scopus 로고
    • Magnetic resonance angiography of the central chest veins. A new gold standard?
    • Hartnell GG, Hughes LA, Finn JP, Esterbrook Longmaid H. Magnetic resonance angiography of the central chest veins. A new gold standard? Chest 1995; 107: 1053-7.
    • (1995) Chest , vol.107 , pp. 1053-1057
    • Hartnell, G.G.1    Hughes, L.A.2    Finn, J.P.3    Esterbrook Longmaid, H.4
  • 6
    • 0032737423 scopus 로고    scopus 로고
    • Three-dimensional gadolinium-enhanced MR venographic evaluation of patency of central veins in the thorax: Initial experience
    • Shinde TS, Lee VS, Rofsky NM, Krinsky GA, Weinreb JC. Three-dimensional gadolinium-enhanced MR venographic evaluation of patency of central veins in the thorax: initial experience. Radiology 1999; 213: 555-60.
    • (1999) Radiology , vol.213 , pp. 555-560
    • Shinde, T.S.1    Lee, V.S.2    Rofsky, N.M.3    Krinsky, G.A.4    Weinreb, J.C.5
  • 7
    • 0035161445 scopus 로고    scopus 로고
    • Three-dimensional gadolinium-enhanced magnetic resonance venography in suspected thrombo-occlusive disease of the central chest veins
    • Kroencke TJ, Taupitz M, Arnold R, Fritsche L, Hamm B. Three-dimensional gadolinium-enhanced magnetic resonance venography in suspected thrombo-occlusive disease of the central chest veins. Chest 2001; 120: 1570-6.
    • (2001) Chest , vol.120 , pp. 1570-1576
    • Kroencke, T.J.1    Taupitz, M.2    Arnold, R.3    Fritsche, L.4    Hamm, B.5
  • 8
    • 0035502328 scopus 로고    scopus 로고
    • 3D gadolinium-enhanced MRI venography: Evaluation of central chest veins and impact on patient management
    • Oxtoby JW, Widjaja E, Gibson KM, Uzoka K. 3D gadolinium-enhanced MRI venography: evaluation of central chest veins and impact on patient management. Clin Radiol 2001; 56: 887-94.
    • (2001) Clin. Radiol. , vol.56 , pp. 887-894
    • Oxtoby, J.W.1    Widjaja, E.2    Gibson, K.M.3    Uzoka, K.4
  • 9
    • 0031861391 scopus 로고    scopus 로고
    • Three-dimensional low dose gadolinium-enhanced peripheral MR venography
    • Li W, David V, Kaplan R, Edelman RR. Three-dimensional low dose gadolinium-enhanced peripheral MR venography. J Magn Reson Imaging 1998; 8: 630-3.
    • (1998) J. Magn. Reson. Imaging , vol.8 , pp. 630-633
    • Li, W.1    David, V.2    Kaplan, R.3    Edelman, R.R.4
  • 11
    • 0031674240 scopus 로고    scopus 로고
    • Hemodialysis access fistula creation: Preoperative assessment with MR venography and comparison with conventional venography
    • Menegazzo D, Laissy JP, Duerrbach A, et al. Hemodialysis access fistula creation: preoperative assessment with MR venography and comparison with conventional venography. Radiology 1998; 209: 723-8.
    • (1998) Radiology , vol.209 , pp. 723-728
    • Menegazzo, D.1    Laissy, J.P.2    Duerrbach, A.3
  • 12
    • 0348050654 scopus 로고    scopus 로고
    • Magnetic resonance angiography in evaluation of central and peripheral vasculature prior to dialysis surgery
    • Henry ML ed. Chicago: WL Gore & Associates and Precept Press
    • Schuman ES, Quinn SF, Standage BA, et al. Magnetic resonance angiography in evaluation of central and peripheral vasculature prior to dialysis surgery. In: Henry ML ed. Vascular access for hemodialysis-VI. Chicago: WL Gore & Associates and Precept Press 1999; 103-10.
    • (1999) Vascular Access for Hemodialysis-VI , pp. 103-110
    • Schuman, E.S.1    Quinn, S.F.2    Standage, B.A.3
  • 13
    • 0037742391 scopus 로고    scopus 로고
    • Upper limb vein anatomy before hemodialysis fistula creation: Cross-sectional anatomy using MR venography
    • Laissy JP, Fernandez P, Karila-Cohen P, et al. Upper limb vein anatomy before hemodialysis fistula creation: cross-sectional anatomy using MR venography. Eur Radiol 2003; 13: 256-61.
    • (2003) Eur. Radiol. , vol.13 , pp. 256-261
    • Laissy, J.P.1    Fernandez, P.2    Karila-Cohen, P.3
  • 14
  • 15
    • 0034879766 scopus 로고    scopus 로고
    • Direct contrast-enhanced 3D MR venography
    • Ruehm SG, Zimny K, Debatin JF. Direct contrast-enhanced 3D MR venography. Eur Radiol 2001; 11: 102-12.
    • (2001) Eur. Radiol. , vol.11 , pp. 102-112
    • Ruehm, S.G.1    Zimny, K.2    Debatin, J.F.3
  • 18
    • 0029966542 scopus 로고    scopus 로고
    • Magnetic resonance angiography as a technique for the visualization of hemodialysis shunts
    • Konermann M, Sanner B, Laufer U, Josephs W, Odenthal HJ, Horstmann E. Magnetic resonance angiography as a technique for the visualization of hemodialysis shunts. Nephron 1996; 73: 73-8.
    • (1996) Nephron , vol.73 , pp. 73-78
    • Konermann, M.1    Sanner, B.2    Laufer, U.3    Josephs, W.4    Odenthal, H.J.5    Horstmann, E.6
  • 20
    • 0030903267 scopus 로고    scopus 로고
    • Magnetic resonance angiography of hemodialysis fistulas and grafts
    • Thurnher S. Magnetic resonance angiography of hemodialysis fistulas and grafts. Semin Interv Radiol 1997; 14: 101-10.
    • (1997) Semin. Interv. Radiol. , vol.14 , pp. 101-110
    • Thurnher, S.1
  • 21
    • 0032973766 scopus 로고    scopus 로고
    • Failing arteriovenous hemodialysis fistulas: Assessment with magnetic resonance angiography
    • Laissy JP, Menegazzo D, Debray MP, et al. Failing arteriovenous hemodialysis fistulas: assessment with magnetic resonance angiography. Invest Radiol 1999; 34: 218-24.
    • (1999) Invest. Radiol. , vol.34 , pp. 218-224
    • Laissy, J.P.1    Menegazzo, D.2    Debray, M.P.3
  • 23
    • 0033795623 scopus 로고    scopus 로고
    • Failing hemodialysis arteriovenous fistula and percutaneous treatment: Imaging with CT, MRI and digital subtraction angiography
    • Cavagna E, D'Andrea P, Schiavon F, Tarroni G. Failing hemodialysis arteriovenous fistula and percutaneous treatment: imaging with CT, MRI and digital subtraction angiography. Cardiovasc Intervent Radiol 2000; 23: 262-5.
    • (2000) Cardiovasc. Intervent. Radiol. , vol.23 , pp. 262-265
    • Cavagna, E.1    D'Andrea, P.2    Schiavon, F.3    Tarroni, G.4
  • 24
    • 0037217359 scopus 로고    scopus 로고
    • Stenosis detection in forearm hemodialysis arteriovenous fistulae by multiphase contrast-enhanced magnetic resonance angiography: Preliminary experience
    • Planken RN, Tordoir JHM, Dammers R, et al. Stenosis detection in forearm hemodialysis arteriovenous fistulae by multiphase contrast-enhanced magnetic resonance angiography: preliminary experience. J Magn Reson Imaging 2003; 17: 54-64.
    • (2003) J. Magn. Reson. Imaging , vol.17 , pp. 54-64
    • Planken, R.N.1    Tordoir, J.H.M.2    Dammers, R.3
  • 25
    • 0033861916 scopus 로고    scopus 로고
    • Arterial pseudostenosis on first-pass gadolinium-enhanced three-dimensional MR angiography: New observation of a potential pitfall
    • Chiowanich P, Mitchell DG, Ortega HV, Mohamed F. Arterial pseudostenosis on first-pass gadolinium-enhanced three-dimensional MR angiography: new observation of a potential pitfall. Am J Roentgenol 2000; 175: 523-7.
    • (2000) Am. J. Roentgenol. , vol.175 , pp. 523-527
    • Chiowanich, P.1    Mitchell, D.G.2    Ortega, H.V.3    Mohamed, F.4
  • 26
    • 0035088843 scopus 로고    scopus 로고
    • MRA of hemodialysis access grafts and fistulae using selective contrast injection and flow interruption
    • Bos C, Smits JHM, Zijlstra JJ, et al. MRA of hemodialysis access grafts and fistulae using selective contrast injection and flow interruption. Magn Reson Med 2001; 45: 557-61.
    • (2001) Magn. Reson. Med. , vol.45 , pp. 557-561
    • Bos, C.1    Smits, J.H.M.2    Zijlstra, J.J.3
  • 27
    • 0036893355 scopus 로고    scopus 로고
    • Hemodialysis access imaging: Comparison of flow-interrupted contrast-enhanced MR angiography and digital subtraction angiography
    • Smits JHM, Bos C, Elgersma OEH, et al. Hemodialysis access imaging: comparison of flow-interrupted contrast-enhanced MR angiography and digital subtraction angiography. Radiology 2002; 225: 829-34.
    • (2002) Radiology , vol.225 , pp. 829-834
    • Smits, J.H.M.1    Bos, C.2    Elgersma, O.E.H.3
  • 28
    • 1242281440 scopus 로고    scopus 로고
    • Imaging the central veins of hemodialysis accesses: Comparison of direct contrast-enhanced MR venography with conventional venography
    • (submitted)
    • Elgersma OEH, Bartels LW, Bos C, et al. Imaging the central veins of hemodialysis accesses: comparison of direct contrast-enhanced MR venography with conventional venography. Am J Roentgenol (submitted).
    • Am. J. Roentgenol.
    • Elgersma, O.E.H.1    Bartels, L.W.2    Bos, C.3
  • 29
    • 0037407913 scopus 로고    scopus 로고
    • Failing hemodialysis access grafts: Evaluation of complete vascular tree with 3D contrast-enhanced MR angiography with high spatial resolution: Initial results in 10 patients
    • Han KM, Duijm LEM, Thelissen GRP, et al. Failing hemodialysis access grafts: evaluation of complete vascular tree with 3D contrast-enhanced MR angiography with high spatial resolution: initial results in 10 patients. Radiology 2003; 227: 601-5.
    • (2003) Radiology , vol.227 , pp. 601-605
    • Han, K.M.1    Duijm, L.E.M.2    Thelissen, G.R.P.3
  • 31
    • 0029680085 scopus 로고    scopus 로고
    • Nephrotoxicity of high-dose gadolinium compared to iodinated contrast
    • Prince MR, Arnoldus C, Frisoli JK. Nephrotoxicity of high-dose gadolinium compared to iodinated contrast. J Magn Reson Imaging 1996; 6: 162-6.
    • (1996) J. Magn. Reson. Imaging , vol.6 , pp. 162-166
    • Prince, M.R.1    Arnoldus, C.2    Frisoli, J.K.3
  • 32
    • 0033852026 scopus 로고    scopus 로고
    • Safety of approved MR contrast media for intravenous injection
    • Runge VM. Safety of approved MR contrast media for intravenous injection. J Magn Reson Imaging 2000; 12: 205-13.
    • (2000) J. Magn. Reson. Imaging , vol.12 , pp. 205-213
    • Runge, V.M.1
  • 33
    • 0035324584 scopus 로고    scopus 로고
    • Safety of gadolinium contrast agent in hemodialysis patients
    • Okada S, Katagiri K, Kumazaki T, Yokoyama H. Safety of gadolinium contrast agent in hemodialysis patients. Acta Radiol 2001; 42: 339-41.
    • (2001) Acta Radiol. , vol.42 , pp. 339-341
    • Okada, S.1    Katagiri, K.2    Kumazaki, T.3    Yokoyama, H.4
  • 34
    • 0036135655 scopus 로고    scopus 로고
    • Using highly concentrated gadobutrol as an MR contrast agent in patients also requiring hemodialysis: Safety and dialysability
    • Tombach B, Bremer C, Reimer P, et al. Using highly concentrated gadobutrol as an MR contrast agent in patients also requiring hemodialysis: safety and dialysability. Am J Roentgenol 2002; 178: 105-9.
    • (2002) Am. J. Roentgenol. , vol.178 , pp. 105-109
    • Tombach, B.1    Bremer, C.2    Reimer, P.3
  • 35
    • 0036651410 scopus 로고    scopus 로고
    • Contrast agents in patients on dialysis
    • Dawson P. Contrast agents in patients on dialysis. Semin Dial 2002; 15: 232-6.
    • (2002) Semin. Dial. , vol.15 , pp. 232-236
    • Dawson, P.1
  • 37
    • 0035074220 scopus 로고    scopus 로고
    • Upper extremity digital subtraction venography with gadoterate meglumine before fistula creation for hemodialysis
    • Geoffroy O, Tassart M, Le Blanche AF, et al. Upper extremity digital subtraction venography with gadoterate meglumine before fistula creation for hemodialysis. Kidney Int 2001; 59: 1491-7.
    • (2001) Kidney Int. , vol.59 , pp. 1491-1497
    • Geoffroy, O.1    Tassart, M.2    Le Blanche, A.F.3
  • 38
    • 0036784423 scopus 로고    scopus 로고
    • Cadolinium-enhanced digital subtraction angiography of hemodialysis fistulas: A diagnostic and therapeutic approach
    • Le Blanche AF, Tassart M, Deux JF, Rossert J, Bigot JM, Boudghene FP. Cadolinium-enhanced digital subtraction angiography of hemodialysis fistulas: a diagnostic and therapeutic approach. AJR 2002; 179: 1023-8.
    • (2002) AJR , vol.179 , pp. 1023-1028
    • Le Blanche, A.F.1    Tassart, M.2    Deux, J.F.3    Rossert, J.4    Bigot, J.M.5    Boudghene, F.P.6
  • 39
    • 0036186908 scopus 로고    scopus 로고
    • Evaluation of a dedicated dual phased-array surface coil using a black-blood FSE sequence for high resolution MRI of the carotid vessel wall
    • Ouhlous M, Lethimonnier F, Dippel DW, et al. Evaluation of a dedicated dual phased-array surface coil using a black-blood FSE sequence for high resolution MRI of the carotid vessel wall. J Magn Reson Imaging 2002; 15: 344-51.
    • (2002) J. Magn. Reson. Imaging , vol.15 , pp. 344-351
    • Ouhlous, M.1    Lethimonnier, F.2    Dippel, D.W.3
  • 40
    • 0035107929 scopus 로고    scopus 로고
    • MR imaging of vascular stents: Effects of susceptibility, flow, and radiofrequency eddy currents
    • Bartels LW, Smits HFM, Bakker CJG, Viergever MA. MR imaging of vascular stents: effects of susceptibility, flow, and radiofrequency eddy currents. J Vasc Interv Radiol 2001; 12: 365-71.
    • (2001) J. Vasc. Interv. Radiol. , vol.12 , pp. 365-371
    • Bartels, L.W.1    Smits, H.F.M.2    Bakker, C.J.G.3    Viergever, M.A.4
  • 41
    • 0036135370 scopus 로고    scopus 로고
    • Improved lumen visualization in metallic vascular implants by reducing RF artifacts
    • Bartels LW, Bakker CJG, Viergever MA. Improved lumen visualization in metallic vascular implants by reducing RF artifacts. Magn Reson Med 2002; 47: 171-80.
    • (2002) Magn. Reson. Med. , vol.47 , pp. 171-180
    • Bartels, L.W.1    Bakker, C.J.G.2    Viergever, M.A.3
  • 43
    • 0031596095 scopus 로고    scopus 로고
    • Blood flow quantification in hemodialysis fistulae by phase contrast MR angiography (PC-MRA) in comparison to duplex sonography
    • Gutberlet M, Venz S, Kahl A, et al. Blood flow quantification in hemodialysis fistulae by phase contrast MR angiography (PC-MRA) in comparison to duplex sonography. Fortschr Roentgenstr 1998; 169: 163-9.
    • (1998) Fortschr Roentgenstr , vol.169 , pp. 163-169
    • Gutberlet, M.1    Venz, S.2    Kahl, A.3
  • 44
    • 0030372749 scopus 로고    scopus 로고
    • Access flow measurements in hemodialysis patients: In vivo validation of an ultrasound dilution technique
    • Bosman PJ, Boereboom FTJ, Bakker CJG, et al. Access flow measurements in hemodialysis patients: In vivo validation of an ultrasound dilution technique. J Am Soc Nephrology 1996; 7: 966-9.
    • (1996) J. Am. Soc. Nephrology , vol.7 , pp. 966-969
    • Bosman, P.J.1    Boereboom, F.T.J.2    Bakker, C.J.G.3
  • 47
    • 0344628883 scopus 로고    scopus 로고
    • Haemodialysis access graft with shunting through an iatrogenic fistula - The diagnostic role of magnetic resonance flow measurement
    • Van Kempen BPM, Smits HFM, Blankestijn PJ. Haemodialysis access graft with shunting through an iatrogenic fistula - the diagnostic role of magnetic resonance flow measurement. Nephrol Dial Transplant 1999; 14: 444-6.
    • (1999) Nephrol. Dial. Transplant. , vol.14 , pp. 444-446
    • Van Kempen, B.P.M.1    Smits, H.F.M.2    Blankestijn, P.J.3
  • 50
    • 0004253692 scopus 로고    scopus 로고
    • (ed). Philadelphia: Mosby-Year-Book Inc
    • RB Lufkin RB (ed). Interventional MRI. Philadelphia: Mosby-Year-Book Inc., 1999.
    • (1999) Interventional MRI
    • Lufkin, R.B.1
  • 51
    • 0041672272 scopus 로고    scopus 로고
    • Endovascular interventional magnetic resonance imaging
    • Bartels LW, Bakker CJG. Endovascular interventional magnetic resonance imaging. Phys Med Biol 2003; 48: R37-R64.
    • (2003) Phys. Med. Biol. , vol.48
    • Bartels, L.W.1    Bakker, C.J.G.2
  • 52
    • 0032158660 scopus 로고    scopus 로고
    • Endovascular interventional MR: Balloon angioplasty in a flow phantom of a hemodialysis access graft taped onto the forearm of a volunteer
    • Smits HFM, Bos C, van der Weide R, Bakker CJG. Endovascular interventional MR: Balloon angioplasty in a flow phantom of a hemodialysis access graft taped onto the forearm of a volunteer. J Vasc Intervent Radiol 1998; 9: 840-5.
    • (1998) J. Vasc. Intervent. Radiol. , vol.9 , pp. 840-845
    • Smits, H.F.M.1    Bos, C.2    van der Weide, R.3    Bakker, C.J.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.