-
1
-
-
0026494966
-
MR of the brain using fluid-attenuated inversion recovery (FLAIR) pulse sequences
-
De Coene B, Hajnal JV, Gatehouse P, et al. MR of the brain using fluid-attenuated inversion recovery (FLAIR) pulse sequences. AJNR Am J Neuroradiol 1992;13:1555-1564
-
(1992)
AJNR Am J Neuroradiol
, vol.13
, pp. 1555-1564
-
-
De Coene, B.1
Hajnal, J.V.2
Gatehouse, P.3
-
2
-
-
0027536957
-
MRI diffusion-weighted imaging of the brain: Contributions to image contrast from CSF signal reduction, use of a long echo time and diffusion effects
-
Oatridge A, Hajnal JV, Cowan FM, Baudouin CJ, Young IR, Bydder GM. MRI diffusion-weighted imaging of the brain: contributions to image contrast from CSF signal reduction, use of a long echo time and diffusion effects. Clin Radiol 1993;47:82-90
-
(1993)
Clin Radiol
, vol.47
, pp. 82-90
-
-
Oatridge, A.1
Hajnal, J.V.2
Cowan, F.M.3
Baudouin, C.J.4
Young, I.R.5
Bydder, G.M.6
-
3
-
-
0027992912
-
MR of acute subarachnoid hemorrhage: A preliminary report of fluid-attenuated inversion-recovery pulse sequences
-
Noguchi K, Ogawa T, Inugami A, Toyoshima H, Okudera T, Uemura K. MR of acute subarachnoid hemorrhage: a preliminary report of fluid-attenuated inversion-recovery pulse sequences. AJNR Am J Neuroradiol 1994;15:1940-1943
-
(1994)
AJNR Am J Neuroradiol
, vol.15
, pp. 1940-1943
-
-
Noguchi, K.1
Ogawa, T.2
Inugami, A.3
Toyoshima, H.4
Okudera, T.5
Uemura, K.6
-
4
-
-
0036117854
-
Subcortical low intensity on MR images of meningitis, viral encephalitis, and leptomeningeal metastasis
-
Lee JH, Na DG, Choi KH, et al. Subcortical low intensity on MR images of meningitis, viral encephalitis, and leptomeningeal metastasis. AJNR Am J Neuroradiol 2002;23:535-542
-
(2002)
AJNR Am J Neuroradiol
, vol.23
, pp. 535-542
-
-
Lee, J.H.1
Na, D.G.2
Choi, K.H.3
-
5
-
-
0031856530
-
Subarachnoid space disease: Diagnosis with fluid-attenuated inversion-recovery MR imaging and comparison with gadolinium-enhanced spin-echo MR imaging-blinded reader study
-
Singer MB, Atlas SW, Drayer BP. Subarachnoid space disease: diagnosis with fluid-attenuated inversion-recovery MR imaging and comparison with gadolinium-enhanced spin-echo MR imaging-blinded reader study. Radiology 1998;208:417-422
-
(1998)
Radiology
, vol.208
, pp. 417-422
-
-
Singer, M.B.1
Atlas, S.W.2
Drayer, B.P.3
-
7
-
-
0035112678
-
Hyperintense signal abnormality in subarachnoid spaces and basal cisterns on MR images of children anesthetized with propofol: New fluid-attenuated inversion recovery finding
-
Filippi CG, Ulug AM, Lin D, Heier LA, Zimmerman RD. Hyperintense signal abnormality in subarachnoid spaces and basal cisterns on MR images of children anesthetized with propofol: new fluid-attenuated inversion recovery finding. AJNR Am J Neuroradiol 2001;22:394-399
-
(2001)
AJNR Am J Neuroradiol
, vol.22
, pp. 394-399
-
-
Filippi, C.G.1
Ulug, A.M.2
Lin, D.3
Heier, L.A.4
Zimmerman, R.D.5
-
8
-
-
0035130841
-
Cerebrospinal fluid signal intensity increase on FLAIR MR images in patients under general anesthesia: The role of supplemental O2
-
Deliganis AV, Fisher DJ, Lam AM, Maravilla KR. Cerebrospinal fluid signal intensity increase on FLAIR MR images in patients under general anesthesia: the role of supplemental O2. Radiology 2001;218:152-156
-
(2001)
Radiology
, vol.218
, pp. 152-156
-
-
Deliganis, A.V.1
Fisher, D.J.2
Lam, A.M.3
Maravilla, K.R.4
-
9
-
-
0023190366
-
Methodology for the measurement and analysis of relaxation times in proton imaging
-
MacFall JR, Wehrli FW, Breger RK, Johnson GA. Methodology for the measurement and analysis of relaxation times in proton imaging. Magn Reson Imaging 1987;5:209-220
-
(1987)
Magn Reson Imaging
, vol.5
, pp. 209-220
-
-
MacFall, J.R.1
Wehrli, F.W.2
Breger, R.K.3
Johnson, G.A.4
-
10
-
-
0033434132
-
Methods of measureing spine-lattice (T1) relaxation times: An annotated bibliography
-
Kingsley PB. Methods of measureing spine-lattice (T1) relaxation times: an annotated bibliography. Concepts Magn Reson 1999;11:243-276
-
(1999)
Concepts Magn Reson
, vol.11
, pp. 243-276
-
-
Kingsley, P.B.1
-
11
-
-
0011105584
-
A modified fast inversion-recovery technique for spine-lattice relaxation measurements
-
Gupta RK, Ferretti JA, Becker EA, Weiss GH. A modified fast inversion-recovery technique for spine-lattice relaxation measurements. J Magn Reson 1980;38:447-452
-
(1980)
J Magn Reson
, vol.38
, pp. 447-452
-
-
Gupta, R.K.1
Ferretti, J.A.2
Becker, E.A.3
Weiss, G.H.4
-
12
-
-
0018376644
-
Relationship between arterial and cisternal CSF oxygen tension in rabbits
-
Jankowska L, Grieb P. Relationship between arterial and cisternal CSF oxygen tension in rabbits. Am J Physiol 1979;236:F220-225
-
(1979)
Am J Physiol
, vol.236
-
-
Jankowska, L.1
Grieb, P.2
-
13
-
-
0014177446
-
Dynamics of oxygen tension in the cisternal cerebrospinal fluid of the rhesus monkey
-
Yarnell P, Charlton G, Merril CR, Ghiardi F, Ommaya AK. Dynamics of oxygen tension in the cisternal cerebrospinal fluid of the rhesus monkey. J Neurosurg 1967;27:515-524
-
(1967)
J Neurosurg
, vol.27
, pp. 515-524
-
-
Yarnell, P.1
Charlton, G.2
Merril, C.R.3
Ghiardi, F.4
Ommaya, A.K.5
-
17
-
-
1242289727
-
The paramagnetic effect of supplemental oxygen on CSF: Healthy volunteers and phantom studies
-
Vancouver
-
Ishikawa M, Anzai Y, Shaw WD, Artru A, Maravilla KR. The paramagnetic effect of supplemental oxygen on CSF: healthy volunteers and phantom studies. Presented at the Annual Meeting of the American Society of Neuroradiology, Vancouver, 2002
-
(2002)
Annual Meeting of the American Society of Neuroradiology
-
-
Ishikawa, M.1
Anzai, Y.2
Shaw, W.D.3
Artru, A.4
Maravilla, K.R.5
-
18
-
-
0036720623
-
Fraction of inspired oxygen in relation to cerebrospinal fluid hyperintensity on FLAIR MR imaging of the brain in children and young adults undergoing anesthesia
-
Frigon C, Jardine DS, Weinberger E, Heckbert SR, Shaw DW. Fraction of inspired oxygen in relation to cerebrospinal fluid hyperintensity on FLAIR MR imaging of the brain in children and young adults undergoing anesthesia. AJR Am J Roentgenol 2002;179:791-796
-
(2002)
AJR Am J Roentgenol
, vol.179
, pp. 791-796
-
-
Frigon, C.1
Jardine, D.S.2
Weinberger, E.3
Heckbert, S.R.4
Shaw, D.W.5
-
20
-
-
0027767808
-
Monitoring cerebral oxygenation: Experimental studies and preliminary clinical results of continuous monitoring of cerebrospinal fluid and brain tissue oxygen tension
-
Maas AI, Fleckenstein W, de Jong DA, van Santbrink H. Monitoring cerebral oxygenation: experimental studies and preliminary clinical results of continuous monitoring of cerebrospinal fluid and brain tissue oxygen tension. Acta Neurochir Suppl (Wien) 1993;59:50-57
-
(1993)
Acta Neurochir Suppl (Wien)
, vol.59
, pp. 50-57
-
-
Maas, A.I.1
Fleckenstein, W.2
De Jong, D.A.3
Van Santbrink, H.4
-
21
-
-
0034055390
-
Contrast optimization of fluid-attenuated inversion-recovery (FLAIR) MR imaging in patients with high CSF blood or protein content
-
Essig M, Bock M. Contrast optimization of fluid-attenuated inversion-recovery (FLAIR) MR imaging in patients with high CSF blood or protein content. Magn Reson Med 2000;43:764-767
-
(2000)
Magn Reson Med
, vol.43
, pp. 764-767
-
-
Essig, M.1
Bock, M.2
-
22
-
-
0028786124
-
Contrast optimization of fluid-attenuated inversion recovery (FLAIR) imaging
-
Rydberg JN, Riederer SJ, Rydberg CH, Jack CR. Contrast optimization of fluid-attenuated inversion recovery (FLAIR) imaging. Magn Reson Med 1995;34:868-877
-
(1995)
Magn Reson Med
, vol.34
, pp. 868-877
-
-
Rydberg, J.N.1
Riederer, S.J.2
Rydberg, C.H.3
Jack, C.R.4
-
23
-
-
0030804894
-
Fluid-attenuated inversion recovery MR imaging: Identification of protein concentration thresholds for CSF hyperintensity
-
Melhem ER, Jara H, Eustace S. Fluid-attenuated inversion recovery MR imaging: identification of protein concentration thresholds for CSF hyperintensity. AJR Am J Roentgenol 1997;169:859-862
-
(1997)
AJR Am J Roentgenol
, vol.169
, pp. 859-862
-
-
Melhem, E.R.1
Jara, H.2
Eustace, S.3
-
24
-
-
0035145162
-
Sulcal hyperintensity on fluid-attenuated inversion recovery MR images in patients without apparent cerebrospinal fluid abnormality
-
Taoka T, Yuh WT, White ML, Quets JP, Maley JE, Ueda T. Sulcal hyperintensity on fluid-attenuated inversion recovery MR images in patients without apparent cerebrospinal fluid abnormality. AJR Am J Roentgenol 2001;176:519-524
-
(2001)
AJR Am J Roentgenol
, vol.176
, pp. 519-524
-
-
Taoka, T.1
Yuh, W.T.2
White, M.L.3
Quets, J.P.4
Maley, J.E.5
Ueda, T.6
|