메뉴 건너뛰기




Volumn 50, Issue 11, 2004, Pages 163-171

Dynamic monitoring system for full-scale wastewater treatment plants

Author keywords

Biological wastewater treatment; Disturbance detection and diagnosis; Dynamic process; Independent component analysis (ICA); Multivariate statistical process control (MSPC); On line monitoring

Indexed keywords

INDEPENDENT COMPONENT ANALYSIS; INDUSTRIAL PLANTS; LINEAR SYSTEMS; MONITORING; PRINCIPAL COMPONENT ANALYSIS;

EID: 12344332870     PISSN: 02731223     EISSN: None     Source Type: Journal    
DOI: 10.2166/wst.2004.0684     Document Type: Article
Times cited : (16)

References (12)
  • 1
    • 0032187518 scopus 로고    scopus 로고
    • Blind signal separation: Statistical principles
    • Cardoso, J.-F. (1998). Blind signal separation: Statistical principles. Proc. of the IEEE, 86(10), 2009-2025.
    • (1998) Proc. of the IEEE , vol.86 , Issue.10 , pp. 2009-2025
    • Cardoso, J.-F.1
  • 4
    • 0028892168 scopus 로고
    • Disturbance detection and isolation by dynamic principal component analysis
    • Ku, W., Storer, R.H. and Georgakis, C. (1995). Disturbance detection and isolation by dynamic principal component analysis. Chemom. and Intel. Lab. Sys., 30, 179-196.
    • (1995) Chemom. and Intel. Lab. Sys. , vol.30 , pp. 179-196
    • Ku, W.1    Storer, R.H.2    Georgakis, C.3
  • 5
    • 0042123781 scopus 로고    scopus 로고
    • New monitoring technique with ICA algorithm in wastewater treatment process
    • Lee, J., Yoo, C.K. and Lee, I.-B. (2003). New monitoring technique with ICA algorithm in wastewater treatment process. Wat. Sci. Tech., 47(12), 49-56.
    • (2003) Wat. Sci. Tech. , vol.47 , Issue.12 , pp. 49-56
    • Lee, J.1    Yoo, C.K.2    Lee, I.-B.3
  • 6
    • 0031208457 scopus 로고    scopus 로고
    • Statistical monitoring of multivariable dynamic processes with state-space models
    • Negiz, A. and Cinar, A. (1997). Statistical monitoring of multivariable dynamic processes with state-space models. AIChE J., 43(8), 2002-2020.
    • (1997) AIChE J. , vol.43 , Issue.8 , pp. 2002-2020
    • Negiz, A.1    Cinar, A.2
  • 7
    • 0034908862 scopus 로고    scopus 로고
    • Adaptive and multiscale monitoring of wastewater treatment operation
    • Rosen, C. and Lennox, J.A. (2001). Adaptive and multiscale monitoring of wastewater treatment operation. Wat. Res., 35 14), 3402-3410.
    • (2001) Wat. Res. , vol.35 , Issue.14 , pp. 3402-3410
    • Rosen, C.1    Lennox, J.A.2
  • 8
    • 0034621334 scopus 로고    scopus 로고
    • Fault detection in industrial processes using canonical variate analysis and dynamic PCA
    • Russell, E.L., Chiang, L.H. and Braatz, R.D. (2000). Fault detection in industrial processes using canonical variate analysis and dynamic PCA. Chemom. and Intel. Lab. Sys., 51, 81-93.
    • (2000) Chemom. and Intel. Lab. Sys. , vol.51 , pp. 81-93
    • Russell, E.L.1    Chiang, L.H.2    Braatz, R.D.3
  • 9
    • 0030530039 scopus 로고    scopus 로고
    • The process chemometrics approach to process monitoring and fault detection
    • Wise, B.M. and Gallagher, N.B. (1996). The process chemometrics approach to process monitoring and fault detection. J. Process Control, 6(6), 329-348.
    • (1996) J. Process Control , vol.6 , Issue.6 , pp. 329-348
    • Wise, B.M.1    Gallagher, N.B.2
  • 10
    • 0037151456 scopus 로고    scopus 로고
    • Dynamic monitoring method for multiscale fault detection and diagnosis in MSPC
    • Yoo, C.K., Choi, S.W. and Lee, I.-B. (2002). Dynamic monitoring method for multiscale fault detection and diagnosis in MSPC. I&EC, 41, 4303-4317.
    • (2002) I&EC , vol.41 , pp. 4303-4317
    • Yoo, C.K.1    Choi, S.W.2    Lee, I.-B.3
  • 11
    • 2342615505 scopus 로고    scopus 로고
    • On-line monitoring of batch processes using multiway independent component analysis
    • Yoo, C.K., Lee, J., Vanrolleghem, P.A. and Lee, I. (2004a). On-line monitoring of batch processes using multiway independent component analysis. Chemom. and Intel. Lab. Sys., 71(2), 151-163.
    • (2004) Chemom. and Intel. Lab. Sys. , vol.71 , Issue.2 , pp. 151-163
    • Yoo, C.K.1    Lee, J.2    Vanrolleghem, P.A.3    Lee, I.4
  • 12
    • 1542408546 scopus 로고    scopus 로고
    • Application of multiway ICA monitoring method in SBR process
    • Yoo, C.K., Lee, D.S. and Vanrolleghem, P.A. (2004b). Application of multiway ICA monitoring method in SBR process. Wat. Res., 38(7), 1715-1732.
    • (2004) Wat. Res. , vol.38 , Issue.7 , pp. 1715-1732
    • Yoo, C.K.1    Lee, D.S.2    Vanrolleghem, P.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.