-
1
-
-
0033073294
-
Early outcome of hybrid external fixation for fracture of the distal tibia
-
J.O. Anglen Early outcome of hybrid external fixation for fracture of the distal tibia J Orthop Trauma 13 2 1999 92 97
-
(1999)
J Orthop Trauma
, vol.13
, Issue.2
, pp. 92-97
-
-
Anglen, J.O.1
-
2
-
-
0033752683
-
The anterior T-frame external fixator for high-energy proximal tibial fractures
-
Gk. Bal, R.S. Kuo, and J.R. Chapman The anterior T-frame external fixator for high-energy proximal tibial fractures Clin Orthop 380 2000 234 240
-
(2000)
Clin Orthop
, vol.380
, pp. 234-240
-
-
Bal, Gk.1
Kuo, R.S.2
Chapman, J.R.3
-
3
-
-
0022650940
-
External fixation of the tibia. Basic concepts and prospective evaluation
-
F. Behrens, and K. Seals External fixation of the tibia. Basic concepts and prospective evaluation J Bone Joint Surg Br 68B 1998 246 254
-
(1998)
J Bone Joint Surg Br
, vol.68
, pp. 246-254
-
-
Behrens, F.1
Seals, K.2
-
4
-
-
0023790817
-
Anatomic basis for implantation of the Ilizarov system in the leg
-
F. Borrione, J.L. Jouve, and R. Louis Anatomic basis for implantation of the Ilizarov system in the leg Surg Radiol Anat 10 1988 283 289
-
(1988)
Surg Radiol Anat
, vol.10
, pp. 283-289
-
-
Borrione, F.1
Jouve, J.L.2
Louis, R.3
-
5
-
-
0037231558
-
The proximal tibiofibular joint. An anatomic study
-
M. Bozkurt, E. Yilmaz, and D. Atlihan The proximal tibiofibular joint. An anatomic study Clin Orthop 406 2003 136 140
-
(2003)
Clin Orthop
, vol.406
, pp. 136-140
-
-
Bozkurt, M.1
Yilmaz, E.2
Atlihan, D.3
-
7
-
-
0033126380
-
Safe extracapsular placement of proximal tibia transfixation pins
-
T.A. DeCoster, M.K. Crawford, and M. Kraut Safe extracapsular placement of proximal tibia transfixation pins J Orthop Trauma 13 4 1999 236 240
-
(1999)
J Orthop Trauma
, vol.13
, Issue.4
, pp. 236-240
-
-
Decoster, T.A.1
Crawford, M.K.2
Kraut, M.3
-
8
-
-
0034572826
-
Open reduction and internal fixation of tibial pilon fractures
-
K.A. Egol, P. Wolinsky, and K.J. Koval Open reduction and internal fixation of tibial pilon fractures Foot Ankle Clin 5 4 2000 873 885
-
(2000)
Foot Ankle Clin
, vol.5
, Issue.4
, pp. 873-885
-
-
Egol, K.A.1
Wolinsky, P.2
Koval, K.J.3
-
10
-
-
0025026849
-
Complications of pin and wire external fixation
-
S.A. Green Complications of pin and wire external fixation Instr Course Lect 39 27 1990 219 227
-
(1990)
Instr Course Lect
, vol.39
, Issue.27
, pp. 219-227
-
-
Green, S.A.1
-
11
-
-
0025689634
-
The use of wires and pins
-
S.A. Green The use of wires and pins Tech Orthop 5 1990 19 25
-
(1990)
Tech Orthop
, vol.5
, pp. 19-25
-
-
Green, S.A.1
-
12
-
-
0037566267
-
Placement of half-pins for supra-acetabular external fixation: An anatomic study
-
G.J. Haidukewych, K. Sanjay, and B. Prpa Placement of half-pins for supra-acetabular external fixation: an anatomic study Clin Orthop 411 2003 269 273
-
(2003)
Clin Orthop
, vol.411
, pp. 269-273
-
-
Haidukewych, G.J.1
Sanjay, K.2
Prpa, B.3
-
13
-
-
0032019547
-
Infections in periarticular fractures of the lower extremity treated with tensioned wire hybrid fixators
-
J.J. Hutson Jr., and G.A. Zych Infections in periarticular fractures of the lower extremity treated with tensioned wire hybrid fixators J Orthop Trauma 12 3 1998 214 218
-
(1998)
J Orthop Trauma
, vol.12
, Issue.3
, pp. 214-218
-
-
Hutson Jr., J.J.1
Zych, G.A.2
-
14
-
-
0036196092
-
The centered lateral fluoroscopic image of the knee: The key to safe tensioned wire placement in periarticular fractures of the proximal tibia
-
JJ. Hutson Jr. The centered lateral fluoroscopic image of the knee: the key to safe tensioned wire placement in periarticular fractures of the proximal tibia J Orthop Trauma 16 3 2002 196 200
-
(2002)
J Orthop Trauma
, vol.16
, Issue.3
, pp. 196-200
-
-
Hutson Jr., J.J.1
-
15
-
-
0036523506
-
The treatment of proximal periarticular tibial fractures with Ilizarov fixators
-
JJ. Hutson Jr. The treatment of proximal periarticular tibial fractures with Ilizarov fixators Tech Orthop 17 2002 58 70
-
(2002)
Tech Orthop
, vol.17
, pp. 58-70
-
-
Hutson Jr., J.J.1
-
16
-
-
0033126381
-
Anatomy of the distal knee joint and pyarthrosis following external fixation
-
J. Hyman, and T. Moore Anatomy of the distal knee joint and pyarthrosis following external fixation J Orthop Trauma 13 4 1999 241 246
-
(1999)
J Orthop Trauma
, vol.13
, Issue.4
, pp. 241-246
-
-
Hyman, J.1
Moore, T.2
-
17
-
-
0032935865
-
Effect of pin location on stability of pelvic external fixation
-
W.T. Kim, T.C. Hearn, and O. Saleem Effect of pin location on stability of pelvic external fixation Clin Orthop 361 1999 237 244
-
(1999)
Clin Orthop
, vol.361
, pp. 237-244
-
-
Kim, W.T.1
Hearn, T.C.2
Saleem, O.3
-
19
-
-
0029017383
-
External fixation and limited internal fixation of complex fractures of the tibial plateau
-
J.L. Marsh, S.T. Smith, and T.T. Do External fixation and limited internal fixation of complex fractures of the tibial plateau J Bone Joint Surg Am 77A 1995 661 673
-
(1995)
J Bone Joint Surg Am
, vol.77
, pp. 661-673
-
-
Marsh, J.L.1
Smith, S.T.2
Do, T.T.3
-
20
-
-
0026438442
-
Complications encountered in the treatment of pilon fractures
-
M.A. McFerran, S.W. Smith, and H.J. Boulas Complications encountered in the treatment of pilon fractures J Orthop Trauma 6 2 1992 195 200
-
(1992)
J Orthop Trauma
, vol.6
, Issue.2
, pp. 195-200
-
-
McFerran, M.A.1
Smith, S.W.2
Boulas, H.J.3
-
21
-
-
0032446455
-
Small wire external fixation of high-energy tibial plateau fractures
-
S.A. Mikulak, S.M. Gold, and D.M. Zinar Small wire external fixation of high-energy tibial plateau fractures Clin Orthop 356 1998 230 238
-
(1998)
Clin Orthop
, vol.356
, pp. 230-238
-
-
Mikulak, S.A.1
Gold, S.M.2
Zinar, D.M.3
-
22
-
-
0036194358
-
Techniques to avoid pin loosening and infection in external fixation
-
A. Moroni, F. Vannini, M. Mosca, and S. Giannini Techniques to avoid pin loosening and infection in external fixation J Orthop Trauma 16 3 2002 189 195
-
(2002)
J Orthop Trauma
, vol.16
, Issue.3
, pp. 189-195
-
-
Moroni, A.1
Vannini, F.2
Mosca, M.3
Giannini, S.4
-
23
-
-
0026030712
-
The small pin circular fixator for proximal tibia fractures with soft-tissue compromise
-
C.P. Murphy, R.D. D'Ambrosia, and E.J. Dabezies The small pin circular fixator for proximal tibia fractures with soft-tissue compromise Orthopedics 14 1991 273 280
-
(1991)
Orthopedics
, vol.14
, pp. 273-280
-
-
Murphy, C.P.1
D'Ambrosia, R.D.2
Dabezies, E.J.3
-
24
-
-
0025964179
-
Small pin circular fixator for distal tibial pilon fractures
-
C.P. Murphy, R.D. D'Ambrosia, and E.J. Dabezies Small pin circular fixator for distal tibial pilon fractures Orthopedics 14 1991 283 290
-
(1991)
Orthopedics
, vol.14
, pp. 283-290
-
-
Murphy, C.P.1
D'Ambrosia, R.D.2
Dabezies, E.J.3
-
25
-
-
0027764563
-
Pin placement in pelvic external fixation
-
M.H. Noordeen, B.A. Taylor, T.W. Briggs, and C.B. Lavy Pin placement in pelvic external fixation Injury 24 9 1993 581 584
-
(1993)
Injury
, vol.24
, Issue.9
, pp. 581-584
-
-
Noordeen, M.H.1
Taylor, B.A.2
Briggs, T.W.3
Lavy, C.B.4
-
26
-
-
0026719736
-
The effect of wire configuration on the stability of the Ilizarov external fixator
-
G.L. Orbay, V.H. Frankel, and F.J. Kummer The effect of wire configuration on the stability of the Ilizarov external fixator Clin Orthop 279 1992 299 302
-
(1992)
Clin Orthop
, vol.279
, pp. 299-302
-
-
Orbay, G.L.1
Frankel, V.H.2
Kummer, F.J.3
-
27
-
-
0038479319
-
Pelvic ring injuries. Assessment and concepts of surgical management
-
T.P. Rüedi W.M. Murphy Thieme-AO Publishing New York
-
T. Pohlemann Pelvic ring injuries. Assessment and concepts of surgical management T.P. Rüedi WM. Murphy AO principles of fracture management 2002 Thieme-AO Publishing New York 402 404
-
(2002)
AO Principles of Fracture Management
, pp. 402-404
-
-
Pohlemann, T.1
-
28
-
-
0347533767
-
The incidence of neurovascular injury during external fixator placement without radiographic assistance for lower extremity diaphyseal fractures: A cadaveric study
-
T. Raymond, R. Hayda, G. Benedetti, and T. Twitero The incidence of neurovascular injury during external fixator placement without radiographic assistance for lower extremity diaphyseal fractures: a cadaveric study J Trauma 55 2003 955 958
-
(2003)
J Trauma
, vol.55
, pp. 955-958
-
-
Raymond, T.1
Hayda, R.2
Benedetti, G.3
Twitero, T.4
-
29
-
-
0035218869
-
Safe placement of proximal tibial transfixation wires with respect to intracapsular penetration
-
J.S. Reid, M. Van Slyke, M. Moulton, and T. Mann Safe placement of proximal tibial transfixation wires with respect to intracapsular penetration J Orthop Trauma 15 1 2001 10 17
-
(2001)
J Orthop Trauma
, vol.15
, Issue.1
, pp. 10-17
-
-
Reid, J.S.1
Van Slyke, M.2
Moulton, M.3
Mann, T.4
-
30
-
-
0017884434
-
Proximal tibiofibular joint: Anatomic-pathologic correlation
-
D. Resnick, J.D. Newell, and J.J. Guerra Proximal tibiofibular joint: anatomic-pathologic correlation Am J Roentgenol 131 1978 133 138
-
(1978)
Am J Roentgenol
, vol.131
, pp. 133-138
-
-
Resnick, D.1
Newell, J.D.2
Guerra, J.J.3
-
32
-
-
0034223220
-
Complications after treatment of tibial pilon fractures:prevention and management strategies
-
D.B. Thordarson Complications after treatment of tibial pilon fractures:prevention and management strategies J Am Acad Orthop Surg 8 4 2000 253 265
-
(2000)
J Am Acad Orthop Surg
, vol.8
, Issue.4
, pp. 253-265
-
-
Thordarson, D.B.1
-
33
-
-
0035215839
-
Soft-tissue injuries with the use of safe corridors for transfixion wire placement during external fixation of distal tibia fractures: An anatomic study
-
M.J. Vives, N.A. Abidi, and S.N. Ishikawa Soft-tissue injuries with the use of safe corridors for transfixion wire placement during external fixation of distal tibia fractures: an anatomic study J Orthop Trauma 15 8 2001 555 559
-
(2001)
J Orthop Trauma
, vol.15
, Issue.8
, pp. 555-559
-
-
Vives, M.J.1
Abidi, N.A.2
Ishikawa, S.N.3
-
34
-
-
0031904941
-
Treatment of complex lateral plateau fractures using Ilizarov techniques
-
J.T. Watson, and C. Coufal Treatment of complex lateral plateau fractures using Ilizarov techniques Clin Orthop 353 1998 97 106
-
(1998)
Clin Orthop
, vol.353
, pp. 97-106
-
-
Watson, J.T.1
Coufal, C.2
-
35
-
-
0029315767
-
The use of combination of internal fixation and hybrid external fixation in severe proximal tibia fractures
-
L.S. Weiner, M. Kelly, and E. Yang The use of combination of internal fixation and hybrid external fixation in severe proximal tibia fractures J Orthop Trauma 9 3 1995 244 250
-
(1995)
J Orthop Trauma
, vol.9
, Issue.3
, pp. 244-250
-
-
Weiner, L.S.1
Kelly, M.2
Yang, E.3
-
36
-
-
0030468369
-
Operative treatment of fractures of the tibial plafond
-
B. Wyrsch, M. McFerran, and M. McAndrew Operative treatment of fractures of the tibial plafond J Bone Joint Surg Am 78A 1996 1646 1657
-
(1996)
J Bone Joint Surg Am
, vol.78
, pp. 1646-1657
-
-
Wyrsch, B.1
McFerran, M.2
McAndrew, M.3
-
37
-
-
0028273073
-
Complications of internal fixation of tibial plateau fractures
-
M.J. Young, and R.L. Barrack Complications of internal fixation of tibial plateau fractures Orthop Rev 23 2 1994 149 154
-
(1994)
Orthop Rev
, vol.23
, Issue.2
, pp. 149-154
-
-
Young, M.J.1
Barrack, R.L.2
|