메뉴 건너뛰기




Volumn 69, Issue 2, 2003, Pages 227-233

Speech perception optimization in deaf with multichannel cochlear implant;Otimização da percepção da fala em deficientes auditivos usuários do sistema de implante coclear multicanal

Author keywords

Cochlear implantation; Deafness; Speech perception

Indexed keywords

ADULT; ADVANCED COMBINATION ENCODER; ARTICLE; CLINICAL ARTICLE; CLINICAL TRIAL; COCHLEA PROSTHESIS; CODING; CONTINUOUS INTERLEAVED SAMPLER; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; EVALUATION; FEMALE; HEARING IMPAIRMENT; HUMAN; MALE; NOISE; QUESTIONNAIRE; RANDOMIZED CONTROLLED TRIAL; SELF EVALUATION; SPECTRAL PEAK; SPEECH DISCRIMINATION; SPEECH PERCEPTION; STATISTICAL SIGNIFICANCE; TECHNIQUE;

EID: 12344284921     PISSN: 00347299     EISSN: None     Source Type: Journal    
DOI: 10.1590/s0034-72992003000200013     Document Type: Article
Times cited : (13)

References (17)
  • 1
    • 0030864174 scopus 로고    scopus 로고
    • Speech recognition as a function of the number of electrodes used in the SPEAK cochlear implant speech processor
    • Fishman KE, Shannon RV, Slattery WH. Speech recognition as a function of the number of electrodes used in the SPEAK cochlear implant speech processor. J Speech Lang Hear Res 1997;40:1201-15.
    • (1997) J Speech Lang Hear Res , vol.40 , pp. 1201-1215
    • Fishman, K.E.1    Shannon, R.V.2    Slattery, W.H.3
  • 2
    • 0031412945 scopus 로고    scopus 로고
    • The use of qualitative questionnaires in patients having and being considered for cochlear implants
    • Zhao F, Stephens SD, Sim SW, Meredith R. The use of qualitative questionnaires in patients having and being considered for cochlear implants. Clin Otolaryngol 1997;22:254-9.
    • (1997) Clin Otolaryngol , vol.22 , pp. 254-259
    • Zhao, F.1    Stephens, S.D.2    Sim, S.W.3    Meredith, R.4
  • 3
    • 0031455163 scopus 로고    scopus 로고
    • Comparisons of Spectra 22 performance with and without an additional noise reduction processor
    • Margo V, Schweitzer C, Gail F. Comparisons of Spectra 22 performance with and without an additional noise reduction processor. Sem Hear 1997;18:405-15.
    • (1997) Sem Hear , vol.18 , pp. 405-415
    • Margo, V.1    Schweitzer, C.2    Gail, F.3
  • 5
    • 84860080943 scopus 로고
    • Logoaudiometria
    • Lacerda AP. Rio de Janeiro: Guanabara Koogan
    • Lacerda AP. Logoaudiometria. In: Lacerda AP. Audiologia clínica. Rio de Janeiro: Guanabara Koogan; 1976.
    • (1976) Audiologia Clínica
    • Lacerda, A.P.1
  • 6
    • 12344267594 scopus 로고    scopus 로고
    • note
    • "Consonat Confusion Study - Confusion program" apresentado no software de sistema de implante coclear Nucleus, na sua unidade de programação - versão 6.90.
  • 7
    • 11144338739 scopus 로고    scopus 로고
    • [Dissertação]. São Paulo: Pontifícia Universidade Católica de São Paulo
    • Valente SLOL. Elaboração de listas de sentenças. [Dissertação]. São Paulo: Pontifícia Universidade Católica de São Paulo; 1998.
    • (1998) Elaboração de Listas de Sentenças
    • Valente, S.L.O.L.1
  • 11
    • 0032912256 scopus 로고    scopus 로고
    • Signal-procesing techniques for cochlear implants
    • Loizou PC. Signal-procesing techniques for cochlear implants. IEEE Eng Med Biol Mag 1999;18:34-46.
    • (1999) IEEE Eng Med Biol Mag , vol.18 , pp. 34-46
    • Loizou, P.C.1
  • 12
    • 0033492004 scopus 로고    scopus 로고
    • A comparison of the growth of open-set speech perception between the nucleus 22 and nucleus 24 cochlear implant systems
    • Waltzman SB, Cohen NL, Roland Junior T. A comparison of the growth of open-set speech perception between the nucleus 22 and nucleus 24 cochlear implant systems. Am J Otol 1999;20:435-41.
    • (1999) Am J Otol , vol.20 , pp. 435-441
    • Waltzman, S.B.1    Cohen, N.L.2    Roland Jr., T.3
  • 14
    • 0030852125 scopus 로고    scopus 로고
    • Results of speech processor upgrade in a population of Veterans Affairs cochlear implant recipients
    • Cohen NL, Waltzman SB, Roland Jr JT, Bromberg B, Cambron N.. Results of speech processor upgrade in a population of Veterans Affairs cochlear implant recipients. Am J Otol 1997;18:462-5.
    • (1997) Am J Otol , vol.18 , pp. 462-465
    • Cohen, N.L.1    Waltzman, S.B.2    Roland Jr., J.T.3    Bromberg, B.4    Cambron, N.5
  • 15
    • 0031027231 scopus 로고    scopus 로고
    • Speech recognition with the MPEAK and SPEAK speech-coding strategies of the Nucleus Cochlear implant
    • Holden LK, Skinner MW, Holden TA. Speech recognition with the MPEAK and SPEAK speech-coding strategies of the Nucleus Cochlear implant. Otolaryngol Head Neck Surg 1997;116:163-7.
    • (1997) Otolaryngol Head Neck Surg , vol.116 , pp. 163-167
    • Holden, L.K.1    Skinner, M.W.2    Holden, T.A.3
  • 16
    • 0031705360 scopus 로고    scopus 로고
    • Speech perception performance in experienced cochlear-implant patients receiving the SPEAK processing strategy in the Nucleus Spectra-22 cochlear implant
    • Parkinson AJ, Parkinson WS, Tyler RS, Lowder MW, Gantz BJ. Speech perception performance in experienced cochlear-implant patients receiving the SPEAK processing strategy in the Nucleus Spectra-22 cochlear implant. J Speech Lang Hear Res 1998;41:1037-87.
    • (1998) J Speech Lang Hear Res , vol.41 , pp. 1037-1087
    • Parkinson, A.J.1    Parkinson, W.S.2    Tyler, R.S.3    Lowder, M.W.4    Gantz, B.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.