메뉴 건너뛰기




Volumn 60, Issue 2, 2005, Pages 196-206

Computer-aided detection of pulmonary nodules: Influence of nodule characteristics on detection performance

Author keywords

Computed tomography (CT); Computers; Diagnostic aid; Diagnostic radiology; Image processing; Lung; Nodule; Observer performance; Thin section

Indexed keywords

IOPROMIDE;

EID: 12344275345     PISSN: 00099260     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.crad.2004.05.014     Document Type: Article
Times cited : (61)

References (32)
  • 1
    • 0029805812 scopus 로고    scopus 로고
    • Peripheral lung cancer: Screening and detection with low-dose spiral CT versus radiography
    • Kaneko M. Eguchi K. Ohmatsu H. et al. Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography Radiology 210 1996 798-802
    • (1996) Radiology , vol.210 , pp. 798-802
    • Kaneko, M.1    Eguchi, K.2    Ohmatsu, H.3
  • 2
    • 0032565365 scopus 로고    scopus 로고
    • Mass screening for lung cancer with mobile spiral computed tomography scanner
    • Sone S. Takashima S. Li F. et al. Mass screening for lung cancer with mobile spiral computed tomography scanner Lancet 351 1998 1242-1245
    • (1998) Lancet , vol.351 , pp. 1242-1245
    • Sone, S.1    Takashima, S.2    Li, F.3
  • 3
    • 0033542870 scopus 로고    scopus 로고
    • Early lung cancer action project: Overall design and findings from baseline screening
    • Henschke C.I. McCauley D.I. Yankelevitz D.F. et al. Early lung cancer action project: Overall design and findings from baseline screening Lancet 354 1999 99-104
    • (1999) Lancet , vol.354 , pp. 99-104
    • Henschke, C.I.1    McCauley, D.I.2    Yankelevitz, D.F.3
  • 4
    • 0034028146 scopus 로고    scopus 로고
    • Characteristics of small lung cancers invisible on conventional chest radiography and detected by population based screening using spiral CT
    • Sone S. Li F. Yang Z.G. et al. Characteristics of small lung cancers invisible on conventional chest radiography and detected by population based screening using spiral CT Br J Radiol 73 2000 137-145
    • (2000) Br. J. Radiol. , vol.73 , pp. 137-145
    • Sone, S.1    Li, F.2    Yang, Z.G.3
  • 5
    • 0036308385 scopus 로고    scopus 로고
    • Lung cancer screening using low-dose spiral CT: Results of baseline and 1-year follow-up studies
    • Nawa T. Nakagawa T. Kusano S. Kawasaki Y. Sugawara Y. Nakata H. Lung cancer screening using low-dose spiral CT: Results of baseline and 1-year follow-up studies Chest 122 2002 15-20
    • (2002) Chest , vol.122 , pp. 15-20
    • Nawa, T.1    Nakagawa, T.2    Kusano, S.3    Kawasaki, Y.4    Sugawara, Y.5    Nakata, H.6
  • 6
    • 0036190266 scopus 로고    scopus 로고
    • Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers
    • Diederich S. Wormanns D. Semik M. et al. Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers Radiology 222 2002 773-781
    • (2002) Radiology , vol.222 , pp. 773-781
    • Diederich, S.1    Wormanns, D.2    Semik, M.3
  • 7
    • 0037083775 scopus 로고    scopus 로고
    • Screeening for lung cancer with low-dose spiral computed tomography
    • Swensen S.J. Jett J.R. Sloan J.A. et al. Screeening for lung cancer with low-dose spiral computed tomography Am J Respir Crit Care Med 165 2002 508-513
    • (2002) Am. J. Respir. Crit. Care Med. , vol.165 , pp. 508-513
    • Swensen, S.J.1    Jett, J.R.2    Sloan, J.A.3
  • 8
    • 0037083316 scopus 로고    scopus 로고
    • Screening for lung cancer with low-dose helical computed tomography: Anti-lung cancer association project
    • Sobue T. Moriyama N. Kaneko M. et al. Screening for lung cancer with low-dose helical computed tomography: Anti-lung cancer association project J Clin Oncol 20 2002 911-920
    • (2002) J. Clin. Oncol. , vol.20 , pp. 911-920
    • Sobue, T.1    Moriyama, N.2    Kaneko, M.3
  • 9
    • 0032765011 scopus 로고    scopus 로고
    • Small pulmonary nodules: Evaluation with repeat CT-preliminary experience
    • Yankelevitz D.F. Gupta R. Zhao B. Henschke C.I. Small pulmonary nodules: Evaluation with repeat CT-preliminary experience Radiology 212 1999 561-566
    • (1999) Radiology , vol.212 , pp. 561-566
    • Yankelevitz, D.F.1    Gupta, R.2    Zhao, B.3    Henschke, C.I.4
  • 10
    • 0028300771 scopus 로고
    • Computerized detection of pulmonary nodules in computed tomography images
    • Giger M.L. Bae K.T. MacMahon H. Computerized detection of pulmonary nodules in computed tomography images Invest Radiol 29 1994 459-465
    • (1994) Invest. Radiol. , vol.29 , pp. 459-465
    • Giger, M.L.1    Bae, K.T.2    MacMahon, H.3
  • 11
    • 0034845242 scopus 로고    scopus 로고
    • Automated detection of lung nodules in CT scans: Preliminary results
    • Armato S.G.III Giger M.L. MacMahon H. Automated detection of lung nodules in CT scans: Preliminary results Med Phys 28 2001 1552-1561
    • (2001) Med. Phys. , vol.28 , pp. 1552-1561
    • Armato III, S.G.1    Giger, M.L.2    MacMahon, H.3
  • 12
    • 0032594058 scopus 로고    scopus 로고
    • Automatic detection of pulmonary nodules in low-dose screening thoracic CT examinations
    • Fiebich M. Wietholt C. Renger B.C. et al. Automatic detection of pulmonary nodules in low-dose screening thoracic CT examinations Proc SPIE 3661 1999 1434-1439
    • (1999) Proc. SPIE , vol.3661 , pp. 1434-1439
    • Fiebich, M.1    Wietholt, C.2    Renger, B.C.3
  • 13
    • 0034848895 scopus 로고    scopus 로고
    • Automatic detection of lung nodules from multi-slice low-dose CT images
    • Fan L. Novak C.L. Qian J. Kohl G. Naidich D.P. Automatic detection of lung nodules from multi-slice low-dose CT images Proc SPIE 4322 2001 1828-1835
    • (2001) Proc. SPIE , vol.4322 , pp. 1828-1835
    • Fan, L.1    Novak, C.L.2    Qian, J.3    Kohl, G.4    Naidich, D.P.5
  • 14
    • 0032594103 scopus 로고    scopus 로고
    • Computer aided diagnosis system for lung cancer based on retrospective helical CT images
    • Satoh H. Ukai Y. Niki N. et al. Computer aided diagnosis system for lung cancer based on retrospective helical CT images Proc SPIE 3661 1999 1324-1335
    • (1999) Proc. SPIE , vol.3661 , pp. 1324-1335
    • Satoh, H.1    Ukai, Y.2    Niki, N.3
  • 15
    • 0001536745 scopus 로고    scopus 로고
    • Image processing for computer-aided diagnosis of lung cancer screening system by CT (LSCT)
    • Okumura T. Miwa T. Kako J. Yamamoto S. et al. Image processing for computer-aided diagnosis of lung cancer screening system by CT (LSCT) Proc SPIE 3338 1998 1314-1322
    • (1998) Proc. SPIE , vol.3338 , pp. 1314-1322
    • Okumura, T.1    Miwa, T.2    Kako, J.3    Yamamoto, S.4
  • 16
    • 6344285523 scopus 로고    scopus 로고
    • Improving optimal radiologic interpretation of low-dose multi-slice lung CT studies using ICAD
    • Fan L. Novak C.L. Naidich D.P. Wei G. Quian J. Ko J.P. Improving optimal radiologic interpretation of low-dose multi-slice lung CT studies using ICAD Radiology 225 2002 475
    • (2002) Radiology , vol.225 , pp. 475
    • Fan, L.1    Novak, C.L.2    Naidich, D.P.3    Wei, G.4    Quian, J.5    Ko, J.P.6
  • 17
    • 0001867392 scopus 로고
    • Algorithm AS 196. Conditional multivariate logistic analysis of stratified case-control studies
    • Krailo M.D. Pike M.C. Algorithm AS 196. Conditional multivariate logistic analysis of stratified case-control studies Appl Stat 33 1984 95-103
    • (1984) Appl. Stat. , vol.33 , pp. 95-103
    • Krailo, M.D.1    Pike, M.C.2
  • 18
    • 0000597127 scopus 로고
    • Algorithm AS 162. Multivariate conditional logistic analysis of stratum-matched case-control studies
    • Smith P.G. Pike M.C. Hill P. Breslow N.E. Day N.E. Algorithm AS 162. Multivariate conditional logistic analysis of stratum-matched case-control studies Appl Stat 30 1981 190-197
    • (1981) Appl. Stat. , vol.30 , pp. 190-197
    • Smith, P.G.1    Pike, M.C.2    Hill, P.3    Breslow, N.E.4    Day, N.E.5
  • 19
    • 0000336139 scopus 로고
    • Remark on the paper by Cox D.R.: Regression methods and life tables
    • Howard S. Remark on the paper by Cox D.R.: Regression methods and life tables J R Stat Soc, Ser B 34 1972 187-220
    • (1972) J. R. Stat. Soc., Ser. B , vol.34 , pp. 187-220
    • Howard, S.1
  • 21
    • 0020083498 scopus 로고
    • The meaning and use of area under a Receiver Operating Characteristic (ROC) curve
    • Hanley J.A. McNeil B.J. The meaning and use of area under a Receiver Operating Characteristic (ROC) curve Radiology 143 1982 29-36
    • (1982) Radiology , vol.143 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.J.2
  • 22
    • 0023710206 scopus 로고
    • Comparing the areas under two or more correlated receiver operating curves: A nonparametric approach
    • DeLong E.R. DeLong D.M. Clarke-Pearson D.L. Comparing the areas under two or more correlated receiver operating curves: A nonparametric approach Biometrics 44 1988 837-845
    • (1988) Biometrics , vol.44 , pp. 837-845
    • DeLong, E.R.1    DeLong, D.M.2    Clarke-Pearson, D.L.3
  • 23
    • 0035134661 scopus 로고    scopus 로고
    • Chest CT automated nodule detection and assessment of change over time-preliminary experience
    • Ko J.P. Betke M. Chest CT automated nodule detection and assessment of change over time-preliminary experience Radiology 218 2001 267-273
    • (2001) Radiology , vol.218 , pp. 267-273
    • Ko, J.P.1    Betke, M.2
  • 24
    • 0028787508 scopus 로고
    • Pulmonary nodules: Improved detection with vascular segmentation and extraction with spiral CT
    • Croisille P. Souto M. Cova M. et al. Pulmonary nodules: Improved detection with vascular segmentation and extraction with spiral CT Radiology 197 1995 397-401
    • (1995) Radiology , vol.197 , pp. 397-401
    • Croisille, P.1    Souto, M.2    Cova, M.3
  • 25
    • 1642580603 scopus 로고    scopus 로고
    • Pulmonary nodules at chest CT: Effect of computer-aided diagnosis on radiologists' detection performance
    • Awai K. Murao K. Ozawa A. et al. Pulmonary nodules at chest CT: effect of computer-aided diagnosis on radiologists' detection performance Radiology 230 2004 347-352
    • (2004) Radiology , vol.230 , pp. 347-352
    • Awai, K.1    Murao, K.2    Ozawa, A.3
  • 26
    • 0035384869 scopus 로고    scopus 로고
    • Automated detection of pulmonary nodules in helical CT images based on an improved templated matching technique
    • Lee Y. Hara T. Fujita H. Itoh S. Ishigaki T. Automated detection of pulmonary nodules in helical CT images based on an improved templated matching technique IEEE Trans Med Imaging 20 2001 595-604
    • (2001) IEEE Trans. Med. Imaging , vol.20 , pp. 595-604
    • Lee, Y.1    Hara, T.2    Fujita, H.3    Itoh, S.4    Ishigaki, T.5
  • 27
    • 85034050905 scopus 로고    scopus 로고
    • Automatic detection of small lung nodules on CT utilizing a local density maximum algorithm
    • Zhao B. Gamsu G. Ginsber M.S. Jiang L. Schwartz L.H. Automatic detection of small lung nodules on CT utilizing a local density maximum algorithm J Appl Clin Med Phys 4 2003 248-260
    • (2003) J. Appl. Clin. Med. Phys. , vol.4 , pp. 248-260
    • Zhao, B.1    Gamsu, G.2    Ginsber, M.S.3    Jiang, L.4    Schwartz, L.H.5
  • 28
    • 0036582337 scopus 로고    scopus 로고
    • Automatic detection of pulmonary nodules at spiral CT: Clinical application of a computer-aided diagnosis system
    • Wormanns D. Fiebich M. Saidi M. Diederich S. Heindel W. Automatic detection of pulmonary nodules at spiral CT: Clinical application of a computer-aided diagnosis system Eur Radiol 12 2002 1052-1057
    • (2002) Eur. Radiol. , vol.12 , pp. 1052-1057
    • Wormanns, D.1    Fiebich, M.2    Saidi, M.3    Diederich, S.4    Heindel, W.5
  • 30
    • 0036891913 scopus 로고    scopus 로고
    • Lung cancer: Performance of automated lung nodule detection applied to cancers missed in a CT screening program
    • Armato S.G.III Li F. Giger M.L. MacMahon H. Sone S. Doi K. Lung cancer: Performance of automated lung nodule detection applied to cancers missed in a CT screening program Radiology 225 2002 685-692
    • (2002) Radiology , vol.225 , pp. 685-692
    • Armato III, S.G.1    Li, F.2    Giger, M.L.3    MacMahon, H.4    Sone, S.5    Doi, K.6
  • 31
    • 0027366655 scopus 로고
    • Variables affecting pulmonary nodule detection with computed tomography: Evaluation with three-dimensional computer simulation
    • Naidich D.P. Rusinek H. McGuinness G. Leitman B. McCauley D.I. Henschke C.I. Variables affecting pulmonary nodule detection with computed tomography: Evaluation with three-dimensional computer simulation J Thorac Imaging 8 1993 291-299
    • (1993) J. Thorac. Imaging , vol.8 , pp. 291-299
    • Naidich, D.P.1    Rusinek, H.2    McGuinness, G.3    Leitman, B.4    McCauley, D.I.5    Henschke, C.I.6
  • 32
    • 0031660284 scopus 로고    scopus 로고
    • Pulmonary nodule detection: Low-dose versus conventional CT
    • Rusinek H. Naidich D.P. McGuinness G. et al. Pulmonary nodule detection: Low-dose versus conventional CT Radiology 209 1998 243-249
    • (1998) Radiology , vol.209 , pp. 243-249
    • Rusinek, H.1    Naidich, D.P.2    McGuinness, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.