메뉴 건너뛰기




Volumn 21, Issue 1, 2005, Pages 45-55

A thermometry system for quality assurance and documentation of whole body hyperthermia procedures

Author keywords

Data acquisition and treatment quality assurance system; Steinhart Hart polynomial fit; Thermistor; Thermometry; Whole body hyperthermia

Indexed keywords

ACCURACY; ARTICLE; BODY TEMPERATURE; CALIBRATION; CANCER THERAPY; CLINICAL STUDY; DEVICE; HEATING; HUMAN; HYPERTHERMIC THERAPY; MEDICAL DOCUMENTATION; NONHODGKIN LYMPHOMA; NORWAY; OVARY CANCER; QUALITY CONTROL; RELIABILITY; TEMPERATURE MEASUREMENT; THERMISTOR; THERMOMETRY; UNIVERSITY HOSPITAL;

EID: 12344259587     PISSN: 02656736     EISSN: None     Source Type: Journal    
DOI: 10.1080/02656730410001711673     Document Type: Article
Times cited : (6)

References (11)
  • 3
    • 12344262513 scopus 로고    scopus 로고
    • Ganzkörper-hyperthermiegerät GKHT 2000 Gebrauchanweisung
    • DM2, Dr Mühlen GmbH & Co KG. Konrad-Adenauer-Straße 9-13, D-45899 Herten, Germany
    • DM2, Dr Mühlen GmbH & Co KG. Ganzkörper-hyperthermiegerät GKHT 2000 Gebrauchanweisung. Konrad-Adenauer-Straße 9-13, D-45899 Herten, Germany; 2000.
    • (2000)
  • 4
    • 12344258588 scopus 로고    scopus 로고
    • Hart Scientific. Revision 052502, 799 E. Utah Valley drive, American Fork, UT 84003-9775, USA
    • Hart Scientific. 1522 Handheld thermometer user's guide. Revision 052502, 799 E. Utah Valley drive, American Fork, UT 84003-9775, USA.
    • 1522 Handheld Thermometer User's Guide
  • 6
    • 12344271850 scopus 로고    scopus 로고
    • YSI Inc. Available online at: 1st Sept. 2003
    • YSI Inc. 2001. Available online at: http://www.ysi.com. 1st Sept. 2003.
    • (2001)
  • 8
    • 12344313944 scopus 로고    scopus 로고
    • Tinsley & Co. Type 5885 275 King Henry's Drive, New Addington, Croydon CR0 0AE, UK
    • Tinsley & Co. Type 5885 Thermometer - Operating instructions. 275 King Henry's Drive, New Addington, Croydon CR0 0AE, UK.
    • Thermometer - Operating Instructions
  • 9
    • 12344311014 scopus 로고    scopus 로고
    • Techne Ltd. Issue 6, February, Techne (Cambridge) Ltd., Duxford, Cambridge CB2 4PZ, UK
    • Techne Ltd. TU-20D Thermoregulator - Operator's manual. Issue 6, February 2000, Techne (Cambridge) Ltd., Duxford, Cambridge CB2 4PZ, UK.
    • (2000) TU-20D Thermoregulator - Operator's Manual
  • 10
    • 49949120161 scopus 로고
    • Calibration curves for thermistores
    • Steinhart JS, Hart SR. Calibration curves for thermistores. Deep Sea Res 1968;15:497-503.
    • (1968) Deep Sea Res. , vol.15 , pp. 497-503
    • Steinhart, J.S.1    Hart, S.R.2
  • 11
    • 12344315667 scopus 로고
    • Reproducibility, stability and linearization of thermistor resistance thermometers
    • Plumb HH, editor. Pittsburgh: Instrument Society of America
    • Trolander HW, Case DA, Harruff RW. Reproducibility, stability and linearization of thermistor resistance thermometers. In: Plumb HH, editor. Temperature. Its Measurement and Control in Science and Industry, Vol. IV. Pittsburgh: Instrument Society of America; 1973. pp. 997-1009.
    • (1973) Temperature. Its Measurement and Control in Science and Industry , vol.4 , pp. 997-1009
    • Trolander, H.W.1    Case, D.A.2    Harruff, R.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.