메뉴 건너뛰기




Volumn 39, Issue 7, 2004, Pages 746-754

JPEG compression of stereoscopic digital images for the diagnosis of diabetic retinopathy via teleophthalmology

Author keywords

Diabetes mellitus; Diabetic retinopathy; Fundus photography; Medical imaging; Retina; Telemedicine; Teleophthalmology

Indexed keywords

ADULT; AGED; ARTICLE; CANADA; CLINICAL ARTICLE; CLINICAL STUDY; COMPUTER GRAPHICS; CONTROLLED STUDY; DIABETIC RETINOPATHY; DIAGNOSTIC ACCURACY; DIGITAL COMPUTER; EARLY TREATMENT DIABETIC RETINOPATHY STUDY STANDARD; EYE FUNDUS; EYE PHOTOGRAPHY; FOLLOW UP; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; JOINT PHOTOGRAPHIC EXPERTS GROUP COMPRESSION; OPHTHALMOLOGY; OPTICAL RESOLUTION; PILOT STUDY; REPRODUCIBILITY; STANDARD; STATISTICS; STEREOSCOPIC VISION; TAGGED IMAGE FILE FORMAT; TELECOMMUNICATION;

EID: 12244301654     PISSN: 00084182     EISSN: 17153360     Source Type: Journal    
DOI: 10.1016/S0008-4182(04)80068-1     Document Type: Article
Times cited : (26)

References (28)
  • 1
    • 0004622365 scopus 로고
    • Preliminary report on effects of photocoagulation therapy
    • Diabetic Retinopathy Study Research Group. Preliminary report on effects of photocoagulation therapy. Am J Ophthalmol 1976;94:505-37.
    • (1976) Am J Ophthalmol , vol.94 , pp. 505-537
  • 4
    • 0023254241 scopus 로고
    • Prevalence of diabetes in Indians and Caucasians living in southwestern Ontario
    • Evers S, McCracken E, Antone I, Deagle G. Prevalence of diabetes in Indians and Caucasians living in southwestern Ontario. Can J Public Health 1987;78(4):240-3.
    • (1987) Can J Public Health , vol.78 , Issue.4 , pp. 240-243
    • Evers, S.1    McCracken, E.2    Antone, I.3    Deagle, G.4
  • 5
    • 0032552944 scopus 로고    scopus 로고
    • 1998 Clinical practice guidelines for the management of diabetes in Canada
    • Canadian Diabetes Association
    • Meltzer S, Leiter L, Daneman D, Gerstein HC, Lau D, Ludwig S, et al. 1998 clinical practice guidelines for the management of diabetes in Canada. Canadian Diabetes Association. Can Med Assoc J 1998; 159 (Suppl 8):S1-29.
    • (1998) Can Med Assoc J , vol.159 , Issue.SUPPL. 8
    • Meltzer, S.1    Leiter, L.2    Daneman, D.3    Gerstein, H.C.4    Lau, D.5    Ludwig, S.6
  • 6
    • 0002030699 scopus 로고
    • Transmitting digital images of the fundus for the West Virginia Diabetic Eye Care Project
    • McGregor G. Transmitting digital images of the fundus for the West Virginia Diabetic Eye Care Project. J Ophthalmic Photogr 1994;16:87-98.
    • (1994) J Ophthalmic Photogr , vol.16 , pp. 87-98
    • McGregor, G.1
  • 7
    • 80052350207 scopus 로고    scopus 로고
    • A new screening tool for diabetic retinopathy: The Canon CR5 45NM retinal camera with Frost Medical Software RIS-lite digital imaging system
    • Young S, George LD, Lusty J, Owens DR. A new screening tool for diabetic retinopathy: the Canon CR5 45NM retinal camera with Frost Medical Software RIS-lite digital imaging system. J Audiov Media Med 1997;20(1):11-4.
    • (1997) J Audiov Media Med , vol.20 , Issue.1 , pp. 11-14
    • Young, S.1    George, L.D.2    Lusty, J.3    Owens, D.R.4
  • 8
    • 0032773703 scopus 로고    scopus 로고
    • Telemedicine and ophthalmology
    • Li HK. Telemedicine and ophthalmology. Surv Ophthalmol 1999;44(1):61-72.
    • (1999) Surv Ophthalmol , vol.44 , Issue.1 , pp. 61-72
    • Li, H.K.1
  • 9
    • 0034931579 scopus 로고    scopus 로고
    • Identification of diabetic retinopathy by stereoscopic digital imaging via teleophthalmology: A comparison to slide film
    • Tennant MTS, Greve MDJ, Rudnisky CJ, Hillson TR, Hinz BJ. Identification of diabetic retinopathy by stereoscopic digital imaging via teleophthalmology: a comparison to slide film. Can J Ophthalmol 2001; 36(4):187-96.
    • (2001) Can J Ophthalmol , vol.36 , Issue.4 , pp. 187-196
    • Tennant, M.T.S.1    Greve, M.D.J.2    Rudnisky, C.J.3    Hillson, T.R.4    Hinz, B.J.5
  • 10
    • 0025845943 scopus 로고
    • Grading diabetic retinopathy from stereoscopic color fundus photographs - An extension of the modified Airlie House classification. ETDRS report number 10
    • Early Treatment Diabetic Retinopathy Study Research Group. Grading diabetic retinopathy from stereoscopic color fundus photographs - an extension of the modified Airlie House classification. ETDRS report number 10. Ophthalmology 1991;98(5 Suppl):786-806.
    • (1991) Ophthalmology , vol.98 , Issue.5 SUPPL. , pp. 786-806
  • 12
    • 0025760218 scopus 로고
    • Fundus photographic risk factors for progression of diabetic retinopathy. ETDRS report number 12
    • Early Treatment Diabetic Retinopathy Study Research Group. Fundus photographic risk factors for progression of diabetic retinopathy. ETDRS report number 12. Ophthalmology 1991;98(5 Suppl):823-33.
    • (1991) Ophthalmology , vol.98 , Issue.5 SUPPL. , pp. 823-833
  • 14
    • 0036153794 scopus 로고    scopus 로고
    • High-resolution stereoscopic digital fundus photography versus contact lens biomicroscopy for the detection of clinically significant macular edema
    • Rudnisky CJ, Hinz BJ, Tennant MTS, De Leon AR, Greve MDJ. High-resolution stereoscopic digital fundus photography versus contact lens biomicroscopy for the detection of clinically significant macular edema. Ophthalmology 2002;109(2):267-74.
    • (2002) Ophthalmology , vol.109 , Issue.2 , pp. 267-274
    • Rudnisky, C.J.1    Hinz, B.J.2    Tennant, M.T.S.3    De Leon, A.R.4    Greve, M.D.J.5
  • 15
    • 0027368092 scopus 로고
    • Estimating kappa from binocular data and comparing marginal probabilities
    • Scheuten HJ. Estimating kappa from binocular data and comparing marginal probabilities. Stat Med 1993;12(23):2207-17.
    • (1993) Stat Med , vol.12 , Issue.23 , pp. 2207-2217
    • Scheuten, H.J.1
  • 16
    • 33645066726 scopus 로고
    • Large sample standard errors of kappa and weighted kappa
    • Fleiss JL. Large sample standard errors of kappa and weighted kappa. Psychol Bull 1969;72:323-7.
    • (1969) Psychol Bull , vol.72 , pp. 323-327
    • Fleiss, J.L.1
  • 17
    • 0025908858 scopus 로고
    • Estimating kappa from binocular data
    • Oden NL. Estimating kappa from binocular data. Stat Med 1991;10(8):1303-11.
    • (1991) Stat Med , vol.10 , Issue.8 , pp. 1303-1311
    • Oden, N.L.1
  • 19
    • 0034067955 scopus 로고    scopus 로고
    • Acceptable levels of digital image compression in chest radiology
    • Smith I, Roszkowski A, Slaughter R, Sterling D. Acceptable levels of digital image compression in chest radiology. Australas Radiol 2000;44(1):32-5.
    • (2000) Australas Radiol , vol.44 , Issue.1 , pp. 32-35
    • Smith, I.1    Roszkowski, A.2    Slaughter, R.3    Sterling, D.4
  • 20
    • 0031883646 scopus 로고    scopus 로고
    • Detection of subtle abnormalities on chest radiographs after irreversible compression
    • Savcenko V, Erickson BJ, Palisson PM, Persons KR, Manduca A, Hartman T, et al. Detection of subtle abnormalities on chest radiographs after irreversible compression. Radiology 1998;206(3):609-16.
    • (1998) Radiology , vol.206 , Issue.3 , pp. 609-616
    • Savcenko, V.1    Erickson, B.J.2    Palisson, P.M.3    Persons, K.R.4    Manduca, A.5    Hartman, T.6
  • 21
    • 0032191133 scopus 로고    scopus 로고
    • A review of compression methods for medical images in PACS
    • Strintzis MG. A review of compression methods for medical images in PACS. Int J Med Inform 1998; 52:159-65.
    • (1998) Int J Med Inform , vol.52 , pp. 159-165
    • Strintzis, M.G.1
  • 22
    • 0033997178 scopus 로고    scopus 로고
    • Assessment of visually lossless irreversible image compression: Comparison of three methods by using an image-comparison workstation
    • Slone RM, Foos DH, Whiting BR, Muka E, Rubin DA, Pilgram TK, et al. Assessment of visually lossless irreversible image compression: comparison of three methods by using an image-comparison workstation. Radiology 2000;215(2):543-53.
    • (2000) Radiology , vol.215 , Issue.2 , pp. 543-553
    • Slone, R.M.1    Foos, D.H.2    Whiting, B.R.3    Muka, E.4    Rubin, D.A.5    Pilgram, T.K.6
  • 23
    • 0026007731 scopus 로고
    • Data compression: Effect on diagnostic accuracy in digital chest radiography
    • MacMahon H, Doi K, Sanada S, Montner SM, Giger ML, Metz CE, et al. Data compression: effect on diagnostic accuracy in digital chest radiography. Radiology 1991;178(1):175-9.
    • (1991) Radiology , vol.178 , Issue.1 , pp. 175-179
    • MacMahon, H.1    Doi, K.2    Sanada, S.3    Montner, S.M.4    Giger, M.L.5    Metz, C.E.6
  • 25
    • 0033945391 scopus 로고    scopus 로고
    • Grading, image analysis, and stereopsis of digitally compressed fundus images
    • Lee MS, Shin DS, Berger JW. Grading, image analysis, and stereopsis of digitally compressed fundus images. Retina 2000;20(3):275-81.
    • (2000) Retina , vol.20 , Issue.3 , pp. 275-281
    • Lee, M.S.1    Shin, D.S.2    Berger, J.W.3
  • 28
    • 18544393430 scopus 로고    scopus 로고
    • Lossy (15:1) JPEG compression of digital coronary angiograms does not limit detection of subtle morphological features
    • Baker WA, Hearne SE, Spero LA, Morris KG, Harrington RA, Sketch MH, et al. Lossy (15:1) JPEG compression of digital coronary angiograms does not limit detection of subtle morphological features. Circulation 1997;96(4):1157-64.
    • (1997) Circulation , vol.96 , Issue.4 , pp. 1157-1164
    • Baker, W.A.1    Hearne, S.E.2    Spero, L.A.3    Morris, K.G.4    Harrington, R.A.5    Sketch, M.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.