메뉴 건너뛰기




Volumn 13, Issue 9, 2005, Pages 881-885

Disinfection of textile materials contaminated with E. coli in liquid carbon dioxide

Author keywords

2 propanol; Disinfection; E. coli; Liquid carbon dioxide; Triclosan

Indexed keywords

CARBON DIOXIDE; CONCENTRATION (PROCESS); DISINFECTION; ESCHERICHIA COLI; IMPURITIES; MOISTURE; ORGANIC SOLVENTS; SPECTROPHOTOMETERS; THERMAL EFFECTS; ULTRAVIOLET RADIATION;

EID: 12244256812     PISSN: 09596526     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jclepro.2004.03.003     Document Type: Article
Times cited : (23)

References (17)
  • 1
    • 12244306442 scopus 로고    scopus 로고
    • http://www.bactria.de
  • 2
    • 12244303194 scopus 로고    scopus 로고
    • http://dc2.uni-bielefeld.de/dc2/wsu-haush/kap_042.htm
  • 3
    • 12244296371 scopus 로고
    • Hemolysis of blood following exposure to an australian-manufactured plastic tubing sterilized by means of EtO gas
    • Clarke C.P., Davidson W.L., Johnston J.B. Hemolysis of blood following exposure to an australian-manufactured plastic tubing sterilized by means of EtO gas. Am J Surg. 53:1966;36
    • (1966) Am J Surg , vol.53 , pp. 36
    • Clarke, C.P.1    Davidson, W.L.2    Johnston, J.B.3
  • 4
    • 0029380344 scopus 로고
    • Currently practised sterilization methods - Some inadvertent consequences
    • Nair P.D. Currently practised sterilization methods - some inadvertent consequences. J Biomater Appl. 10:1995;121-135
    • (1995) J Biomater Appl , vol.10 , pp. 121-135
    • Nair, P.D.1
  • 5
    • 0028139911 scopus 로고
    • Application of high pressure for spore inactivation and protein denaturation
    • Hayakawa I., Kanno T., Tomita M., Fujio Y. Application of high pressure for spore inactivation and protein denaturation. J Food Sci. 59:1994;159-163
    • (1994) J Food Sci , vol.59 , pp. 159-163
    • Hayakawa, I.1    Kanno, T.2    Tomita, M.3    Fujio, Y.4
  • 6
    • 0028005908 scopus 로고
    • Oscillatory compared with continuous high pressure sterilization on Bacillus stearothermophilus spores
    • Hayakawa I., Kanno T., Yoshiyama K., Fujio Y. Oscillatory compared with continuous high pressure sterilization on Bacillus stearothermophilus spores. J Food Sci. 59:1994;164-167
    • (1994) J Food Sci , vol.59 , pp. 164-167
    • Hayakawa, I.1    Kanno, T.2    Yoshiyama, K.3    Fujio, Y.4
  • 7
    • 0029347023 scopus 로고
    • Kinetic analysis of yeast inactivation by high pressure treatment at low temperatures
    • Hashizume C., Kimura K., Hayashi R. Kinetic analysis of yeast inactivation by high pressure treatment at low temperatures. Biosci Biotechnol Biochem. 59:1995;1455-1458
    • (1995) Biosci Biotechnol Biochem , vol.59 , pp. 1455-1458
    • Hashizume, C.1    Kimura, K.2    Hayashi, R.3
  • 8
    • 0031172578 scopus 로고    scopus 로고
    • Autosterilization of biodegradable implants by injection molding process
    • König C., Ruffieux K., Wintermantel E., Blaser J. Autosterilization of biodegradable implants by injection molding process. J Biomed Mater Res. 38:1997;115-119
    • (1997) J Biomed Mater Res , vol.38 , pp. 115-119
    • König, C.1    Ruffieux, K.2    Wintermantel, E.3    Blaser, J.4
  • 11
    • 12244305772 scopus 로고    scopus 로고
    • http://www.micell.com/news.asp
  • 13
    • 12244266627 scopus 로고    scopus 로고
    • http://www.bode-chemie.de
  • 14
    • 12244276966 scopus 로고    scopus 로고
    • http://www.findarticles.com/cf_0/m1200/22_157/62981017/print.jhtml
  • 15
    • 12244280358 scopus 로고    scopus 로고
    • http://www.kumarorganic.com/TCS-MSDS.htm
  • 16
    • 12244295699 scopus 로고    scopus 로고
    • http://www.kumarorganic.com/usesordinary.htm
  • 17
    • 12244258643 scopus 로고    scopus 로고
    • http://www.pharmedmedicare.com/TROX.html


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.